Electronic limit position setting combination

ULP

 = is an abbreviation for 

U

pper 

L

imit 

P

osition.

LLP 

= is an abbreviation for 

L

ower 

L

imit 

P

osition.

Following combinations virtual / physical limit position settings are possible:

Setting electronic limit position

ATTENTION!

 

– The motor starts to move with a short delay time during 

installation phase, when no limit positions are set.

 

Conditions to use the physical (automatic) limit posi-

tion settings: 

The upper limit stop has to be installed.

Ä

Changing motor turning direction

 

– Hold down the button 

  or 

  to 

check the  motor turning direction.

 

– When the motor reacts in opposite direc-

tion (when motor goes down when you

press up and vice-versa), you need to 

change the motor direction. Motor direc-

tion can only be changed  during installa-

tion phase, when no limit positions are set.

 

– Press the button 

 shortly.

 

– The 

red

 LED   starts blinking as long 

as the change motor turning direction 

process is in progress.

 

– The 

red

 LED 

  lit solid if the process 

is   finished.

UP

DOWN

red

Change

turning 

direction

green

yellow

Both upper and lower limit 

position are virtual.

Upper limit position is virtual, 

lower limit position is physical.

Upper limit position is physical, 

lower limit position is virtual.

Both upper and lower limit 

position are physical.

UP

DOWN

red

Change 

turning 

direction

green

yellow

Virtual – Virtual

  Option: start with lower limit position setting 

 

– Hold down the button 

 to move the motor in the re-

quested 

lower

 limit position.

 

– Press the button 

 shortly.

 

– The 

red

 LED of button 

 starts blinking as long as the 

limit setting process is in progress.

 

– The 

red

 LED  of  button 

 lit solid if the process is 

 finished. 

 

– Hold down the button 

 to move the motor in the re-

quested 

upper 

limit position.

 

– Press the button 

 shortly.

 

– The 

green

 LED of button 

 starts blinking as long as 

the limit setting process is in progress.

 

– The 

green

 LED of button 

 lit solid if the process is 

 finished. 

 

– The motor needs the following complete movement 

 (figure 1) to memorize the limit position. (Hold down the 
button 

 to move the motor in the requested direction). 

The motor will give a feedback (short up /down move ment)
to confirm that the installation procedure has  ended.

  Advice:  start with upper limit position setting

 

– Hold down the button 

 to move the motor in the re-

quested 

upper 

limit position.

 

– Press the button 

 shortly.

 

– The 

green

 LED of button 

 starts blinking as long as 

the limit setting process is in progress.

 

– The 

green

 LED of button 

 lit solid if the process is 

 finished. 

 

– Hold down the button 

 to move the motor in the re-

quested 

lower

 limit position.

 

– Press the button 

 shortly.

 

– The 

red

 LED of button 

 starts blinking as long as the 

limit setting process is in progress.

 

– The 

red

 LED  of  button 

 lit solid if the process is 

 finished.

 

– The motor will give a feedback (short up / down move-

ment) to confirm that the installation procedure has 
 ended.

Fig. 1

Содержание VL-ME-230-45 Series

Страница 1: ...y network e g if maintenance work has to be done close to them CONTENTS 1 Safety precautions safety measures 2 Short description identification of products 3 Scope of delivery 4 Intended use 5 Technic...

Страница 2: ...m connection cable Operating instructions Adapter set comprising tube adapter adapter ring Mounting kit comprising safety clip safety cotter 5 Technical data Article VL ME 230 45 10Nm 20Nm 30Nm 50Nm A...

Страница 3: ...e 1 Move the roller shutter or screen completely down before disconnecting the tube connectors Dissasembly of tubular shaft Place the mounting bracket to the desired position Assembly of the motor can...

Страница 4: ...ED yellow LED Intermediate position yellow Button Set Intermediate position Hint Intermediate position Not used for these motor devices OFF when no Intermediate position is set Blinking when programmi...

Страница 5: ...nd lower limit position are physical UP DOWN red Change turning direction green yellow Virtual Virtual Option start with lower limit position setting Hold down the button to move the motor in the re q...

Страница 6: ...motor in the requested direction The motor will give a feedback short up down movement to confirm that the installation procedure has ended Physical Physical Advice start with upper limit position se...

Страница 7: ...downwards 1 Preset endpoint reached 1 Set the end limits again according to the instructions 2 Cutoff by internal temperature fuse 2 Allow the motor to cool down for 20 min Motor stops while moving up...

Отзывы: