Subject to modifications.

© Vestamatic GmbH

2/7

G

H O M E   VL-ME-230-45

Art.-Nr.: 

1100 001 GB 

1518 A08

  •  Vestamatic GmbH  •  Dohrweg 27  •  D-41066 Mönchengladbach 

 •  www.vestamatic.com

2. Short description

 

„

Motor 45 mm tube diameter for roller shutters

 

„

Programmable upper and lower limit position

 

„

Limit positions can be virtual or physical (upper position)

 

„

Parallel connection allowed

 

„

Anti-block function

 

„

Simple setting of the limit position with the “VL-Progset-ME/SMI-230” 

(Art.-no.: 54185775)

 

„

Re-synchronisation of physical limit positions

 

„

Cable 2.5 m white 

4. Intended use

These types of tubular motor described in these manual is intended  solely 

for roller shutters. These types of  tubular motor cannot be used in poten-

tially explosive area.
These types of tubular motor are designed for using in a single roller shut-

ter system.

3. Scope of delivery

 

„

Motor 45 mm tube diameter with 2.5 m connection cable

 

„

Operating instructions

 

„

Adapter set, comprising tube adapter / adapter ring

 

„

Mounting-kit, comprising safety clip / safety cotter

5. Technical data

Article 

          

VL-ME-230-45 / 10Nm

20Nm

30Nm

50Nm

Art.-no.: 01066110 01066120 01066130 01066140

Torque (nominal)

Nm

10

20

30

50

Output speed

rpm

15

15

15

12

Tractive power

kg*

20

40

55

95

Supply voltage

VAC

230

230

230

230

Frequency

Hz

50

50

50

50

Rated power

W

126

165

227

227

Rated current

A

0.55

0.72

0.99

0.99

Running time

Min.

4

4

4

4

Protection degree IP

44

44

44

44

Length L1

mm

461

481

522

551

*

 

Calculation method: 60 mm octagonal shaft, 1.5 m roller shutter height, regardless 

of installation situation, spline, width and friction losses.

6. Installation, assembly, disassembly

Wiring diagram

ATTENTION!

Parallel control of more than one conventional drive motor can 

only be implemented by means of isolating relays.

Ä

Wire colours of motor connection cables:

–  green/yellow:  ground conductor / PE –  brown: phase turning direction 1

–  blue: 

  neutral conductor / N  –  black:  phase turning direction 2

Fig. 4.1

Fig. 4.2

Fig. 4.3

Fig. 4.4

Fig. 4.5

Содержание VL-ME-230-45 Series

Страница 1: ...y network e g if maintenance work has to be done close to them CONTENTS 1 Safety precautions safety measures 2 Short description identification of products 3 Scope of delivery 4 Intended use 5 Technic...

Страница 2: ...m connection cable Operating instructions Adapter set comprising tube adapter adapter ring Mounting kit comprising safety clip safety cotter 5 Technical data Article VL ME 230 45 10Nm 20Nm 30Nm 50Nm A...

Страница 3: ...e 1 Move the roller shutter or screen completely down before disconnecting the tube connectors Dissasembly of tubular shaft Place the mounting bracket to the desired position Assembly of the motor can...

Страница 4: ...ED yellow LED Intermediate position yellow Button Set Intermediate position Hint Intermediate position Not used for these motor devices OFF when no Intermediate position is set Blinking when programmi...

Страница 5: ...nd lower limit position are physical UP DOWN red Change turning direction green yellow Virtual Virtual Option start with lower limit position setting Hold down the button to move the motor in the re q...

Страница 6: ...motor in the requested direction The motor will give a feedback short up down movement to confirm that the installation procedure has ended Physical Physical Advice start with upper limit position se...

Страница 7: ...downwards 1 Preset endpoint reached 1 Set the end limits again according to the instructions 2 Cutoff by internal temperature fuse 2 Allow the motor to cool down for 20 min Motor stops while moving up...

Отзывы: