Erase of the programmed up and down times
The programmed up and down times can only be erased together. To
erase these times the up
and
down buttons have to be pressed at the
same time for 8 seconds. During this setting both LED’s blink quickly.
When the LED’s do not blink anymore, the programmed up and down
times have been erased.
To program the times once again, you will have to act according to
pages 23 and 24.
- 25 -
G
Notes for professional electricians
Installation and basic settings:
1. Switch off the power supply.
2. Remove the cover cap of the
Vestamatic
VestaLogo 500
roller
shutter control by pulling carefully.
3. Separate the supporting frame from the housing.
4. Connect the supporting frame terminal according to the wiring dia-
gram (page 30). Please note the position of the combination frame
Jung CD 500, alpine-white.
Attention: Currently valid VDE standards must be observed
when connecting the device, in particular DIN VDE
0100/0700 as well as the currently valid regulations
of your local power company and accident preven-
tion regulations.
5. Mount the supporting frame in the flush-type box and screw them
together.
6. Slide the housing into the supporting frame and fix them together.
7. Switch on the power supply.
8. Set the selection switch to manual mode and check if the direction
of the motor rotation corresponds with the direction buttons. If not,
exchange terminal 4 with terminal 5.
- 26 -
G