Setting the motor run time
G
-
38 -
Setting the motor run time
The setting for the motor run time depends on size and design of
sunshade. The motor run time of
Vestamatic
Markise Plus 500 V 2.0
sunshade control can be adjusted to the actual run time of the sun-
shade. We recommend this adjustment for the sunshade drives to be
able to perform a tilting function in the automatic and manual mode to
position the slat angle of the blinds directly after the motor run time
has elapsed.
If more than one sunshade control is triggered, the setting of the
motor run time and the tilting time depends on the functionality of the
series connected motor control units.
The preset default setting for the motor run time extracting is
180 seconds.
The running time retract is general 180 seconds.
(Exception: IDS-Function).
(DIP switch on the front side of the device)
Yqwer%&/(X
Example for the DIP switch setting:
motor run time 180 seconds
The DIP switches S1 – S4 are all desig-
nated for setting the tilting pulse
(please see page 39).
G
-
37 -
S5
S6
S7
S8
motor run time
in seconds
OFF
OFF
OFF
OFF
IDS-Function*
OFF
OFF
OFF
ON
10
OFF
OFF
ON
OFF
15
OFF
OFF
ON
ON
18
OFF
ON
OFF
OFF
21
OFF
ON
OFF
ON
24
OFF
ON
ON
OFF
27
OFF
ON
ON
ON
30
ON
OFF
OFF
OFF
35
ON
OFF
OFF
ON
40
ON
OFF
ON
OFF
50
ON
OFF
ON
ON
60
ON
ON
OFF
OFF
80
ON
ON
OFF
ON
100
ON
ON
ON
OFF
120
ON
ON
ON
ON
180
* Only combined with decentralized IDS controller.