19
Trouble shooting
If the range hood or LED
light does not w
ork after installation
• Check if the range hood has been plugged in, make sure that all
power has been turned back ON, fused not blown and all electrical
wiring are properly connected.
• Swap out light assembly to working ones to determine whether it is
caused by defective bulbs. See replacing the bulbs on Page 23.
The range hood vibrates when the blower is on
• The range hood might not have been secured properly on to the ceiling or
wall. Check with your installer.
The blower or fan seems weak
• Check that the duct sized used is at least 6”or 3-1/4 × 10".
Range hood WILL NOT function effciently with insufficient duct size.
For example: 8" duct over 6” hole and loosely secured.
• Check if duct is clogged or if damper unit (half-circular flapper) is not installed
correctly or opening properly. A tight mesh on a side wall cap unit might also
cause restriction to the
airflow.
The lights work but the blower is not spinning at all, is stuck or is rattling.
The blower might be jammed or scraping the bottom due to shipping damage.
Please contact us immediately.
The hood is not venting out properly.
•
Make sure the distance between the stove top and the bottom of the
hood is within
* 28” and 31” in distance
. Due to different ceiling height
configurations, recommended height may not be applicable.
•
Reduce the number of elbows and length of duct work.
Check if all joints are properly connected, sealed and taped.
•
Make sure the power is on high speed for heavy cooking.
Purpose of the slots/holes/openings near the top of the upper chimney:
•
These slots/holes/openings are used to exhaust cleaned air with optional
re-circulating kit. If you did not install one, you do not need them.
NOTE: For all other inquiries, please contact your local reseller.