12 

Operation

 

 

 CAUTION

 

 

CAUTION

 

•  Malfunctions may occur due to electrical noise during momentary power 

failures, lightning strikes, high-capacity motor startup, etc. If the product 
shuts down abnormally for one of these reasons, perform a reset. If this 
occurs frequently, use the anomaly detection sensitivity adjustment (P.10) 
to set the sensitivity to LOW. 

•  When performing a reset using the power switch, once you have turned 

the power OFF, wait 10 seconds or more before turning it ON again. 

•  If the power is repeatedly turned ON and OFF in short cycles, a load will 

be placed on the internal transformer, etc. and shorten the life of the 
device. Try to leave 5 minutes or more for each continuous recurring cycle 
between ON and OFF. 

 

Ion balance adjustment   

This product can enables to adjust ion balance. 
 
If the balance of positive and negative ions produced by the electrode is off, the static electricity 
cannot be removed, or instead, it is produced. This product can output DC voltage in addition to the 
AC high voltage output. By manipulating this DC voltage, the ion balance can be adjusted. 
There is an adjustment knob on the other side of the connectors. 
Turning the knob labeled (ION BALANCE ADJ) to the left or right 
increases or decreases the DC voltage, adjusting the amount of 
positive and negative ions produced by the ionizer. 
 
Carry out adjustments by measuring the actual ion balance with   
a CPM (charged plate monitor) etc. 
 

IF THE PRODUCT HAS BEEN PURCHASED AS A SET WITH AN IONIZER, THE ION BALANCE 
HAS BEEN ADJUSTED BEFOREHAND BASED ON PRE-DETERMINED STANDARD USAGE 
CONDITIONS. BECAUSE THE ION BALANCE WILL VARY DEPENDING ON INSTALLATION 
DISTANCE, USE OF COMPRESSED AIR, ETC., IT IS RECOMMENDED TO PERFORM ION 
BALANCE ADJUSTMENT BASED ON ACTUAL USAGE CONDITIONS.   

 CAUTION

 

 

 

CAUTION

 

•  If the ion balance is an important factor in the location where this product is 

used, use with just 1 ionizer connected to the unit. The ion balance cannot 
be individually adjusted for each ionizer when multiple models are 
connected to the same power supply unit. For example, if 2 ionizers are 
connect to the same unit, and the ion balance is adjusted for one of the, 
ionizers the ion balance of the other ionizer may not be as expected. 

•  Ion balance adjustment cannot be carried out for "SSB bar series". 
  For other ionizers, please consult the instruction manual for each model. 

 

Содержание Stat Buster GP-1

Страница 1: ...Stat Buster No GP 1 Read this instruction manual before use Keep it in a safe handy place for future reference Table of Contents For Your Safely P 2 Product Overview P 3 External View P 5 Circuit Diagram P 6 Installation P 7 Operation P 11 MEMO P 15 Troubleshooting Storage P 16 ...

Страница 2: ... or don t use this product in a place where water oil solvent may be poured and or where corrosive gas such as acid alkali chlorine and so on There is a risk of electric shock and or product breakdown PROHIBITED Don t use this product in a place where a considerable shock and or vibration are given and or where a sharp temperature fluctuation or dew condensation occurs PROHIBITED Be sure to use th...

Страница 3: ...hinery equipment etc connect a 24 VDC 10 1 A power supply In this case connect the 0 V side to ground Product Features AC Output Voltage Adjustment Function This power supply can adjust AC output voltage within the range of 3 5 kV to 7 kV For this reason this can be used with various VESSEL ionizers DC Output Voltage Adjustment Function This power supply can output a variable DC output voltage bet...

Страница 4: ... the internal board Low voltage detection Anomaly detection function will operate when each output drops to about 85 or less of the set voltage due to high voltage short circuit or abnormal sparks Overcurrent detection the anomaly detection function will operate when the output current reaches about 4 mA or more Anomaly detection sensitivity adjustment The anomaly detection response speed can be a...

Страница 5: ...5 External View ...

Страница 6: ...6 Circuit Diagram ...

Страница 7: ...ct uses sensitive electronic circuits so please handle it as gently as possible and avoid subjecting it to shocks etc Do not under any circumstances drill holes into the unit Please install the GP 1 near machinery to which load electrodes bars nozzles air guns etc are connected Secure firmly to a strong frame wall floor etc using 4 M5 screw through the holes in the bottom of the mounting base When...

Страница 8: ...yed value Ex If the tester shows 4 2 V the high voltage output will be 4 2 kV CAUTIONS CAUTIONS Be sure to conduct measurements with the tester in AC voltage measurement mode Do not apply a voltage to the output monitor terminals as it may lead to failure REMEMBER Do not short the output monitor terminals or connect them to ground It may lead to failure Output voltage adjustment Make sure to carry...

Страница 9: ...ther than the aforementioned output selector switch or output adjustment knobs Doing so may lead to accidents or malfunction The top cover is connected to the unit by a ground wire Do not remove or damage this ground wire After making adjustments be sure to put back the top cover Do not use the product without the top cover Anomaly Detection Circuit For safety the anomaly detection circuit automat...

Страница 10: ...ector varies depending on the type of ionizer The maximum load that can be connected to this product in the case of the SSB bar series ionizer is a bar with a total overall length of 5 m Details about our other ionizers can be found in the instruction manual for each model Using this product with loads in excess of the maximum load radically shortens the life of the unit electrode and high voltage...

Страница 11: ...etc shows approximately 0 V 〇 High voltage output is stopped and static elimination ceases Anomaly detection If sparks occur or if there is a high voltage short circuit etc resulting from an anomaly in the high voltage cable electrode or power transformer high voltage output will be turned OFF and the power indicator light will go out 〇 Power indicator light goes out 〇 Error alarm output contacts ...

Страница 12: ...e adjusted There is an adjustment knob on the other side of the connectors Turning the knob labeled ION BALANCE ADJ to the left or right increases or decreases the DC voltage adjusting the amount of positive and negative ions produced by the ionizer Carry out adjustments by measuring the actual ion balance with a CPM charged plate monitor etc IF THE PRODUCT HAS BEEN PURCHASED AS A SET WITH AN IONI...

Страница 13: ...l is coming from the unit The unit is considerably distorted The unit is abnormally hot enough that it cannot be touched with bare hands It is making an unusual humming sound which can be easily heard from 1 m away The power indicator light does not come on even though the power switch is turned to ON CAUTION PROHIBITED Do not use the product in the following conditions Risk of fire or electric sh...

Страница 14: ...ried out for capacitive coupling type antistatic electrode The anomaly detection circuit operates and stops output Bad ground Inspect each ground The load is too great Decrease the load Reduce the number of electrodes or shorten the length of the high voltage cable The electrode and insulation of the ionizer are extremely dirty Clean or replace the electrode needles etc Failure of the electrode or...

Страница 15: ...15 MEMO ...

Страница 16: ... neglect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or contr...

Отзывы: