NetSure™
DC/DC Converter Module
User Manual (UM1C24481500 / 11WA6101WB), Revision G
Specification Number: 1C24481500 Model Number: C24/48-1500
Страница 1: ...NetSure DC DC Converter Module User Manual UM1C24481500 11WA6101WB Revision G Specification Number 1C24481500 Model Number C24 48 1500 ...
Страница 2: ...ols and materials to be used in performing procedures not specifically described in this document This document may contain confidential and or proprietary information of Vertiv Group Corporation and its receipt or possession does not convey any right to reproduce disclose its contents or to manufacture or sell anything that it may describe Reproduction disclosure or use without specific authoriza...
Страница 3: ... 6 Introduction 7 Overview 7 Specifications 7 DC Output Ratings 7 DC Input Ratings 7 Environmental Ratings 8 Compliance Information 9 Standard Features 9 Mechanical Specifications 11 Operation 12 Local Indicators 12 Converter High Voltage Shutdown and Lockout Restart 12 Installing Converter Modules 13 Troubleshooting and Repair 14 Troubleshooting 14 Converter Module Current Sharing Imbalanced 14 C...
Страница 4: ... not avoided ANSI OSHA This admonition is not used for situations that pose a risk only to equipment data or service even if such use appears to be permitted in some of the applicable standards OSHA ALERT Alerts the reader to an action that must be avoided in order to protect equipment software data or service ISO ALERT Alerts the reader to an action that must be performed in order to prevent equi...
Страница 5: ... not hazardously high the input power can deliver large amounts of current DC Output and Battery Voltages DANGER This system produces DC power and may have a battery source connected to it Although the DC voltage is not hazardously high the converters and or battery can deliver large amounts of current Exercise extreme caution not to inadvertently contact or have any tool inadvertently contact an ...
Страница 6: ...ecessary Read and follow wrist strap manufacturer s instructions outlining use of a specific wrist strap 3 Do not touch traces or components on equipment containing static sensitive components Handle equipment containing static sensitive components only by the edges that do not have connector pads 4 After removing equipment containing static sensitive components place the equipment only on conduct...
Страница 7: ...e Filtering With at least 10 of rated full load on the output 20 C to 65 C a Voice band noise is less than 32 dBrnC for more than one converter module or 40 dBrnC for a single converter module when measured with a noise meter using 600 ohm bridged input and C message weighting b Wide band noise does not exceed 250 millivolts peak to peak over the frequency range of 0 Hz to 100 MHz c Wide band nois...
Страница 8: ...00 62 24 86 1 826 54 Environmental Ratings Specification Compliant Temperature Range 20 C to 65 C 4 F to 149 F Reduced Load Temperature Range 50 C to 80 C 122 F to 176 F Deviation to Noise Specs Temperature Range 40 C to 20 C 40 F to 4 F Storage Ambient Temperature Range 40 C to 85 C 40 F to 185 F Humidity This converter module is capable of operating in an ambient relative humidity range of 0 to ...
Страница 9: ...nverter modules will draw no more than 15mA Operation will automatically resume after the input voltage returns to within normal operating limits Output Protection a Overvoltage Protection If output voltage exceeds an adjustable preset value set via controller and the converter module is delivering more than 10 of its rated current the converter module shuts down After approximately 3 seconds the ...
Страница 10: ...nd reported to controller The fans are field replaceable b Fan Control Fan speed is continuously variable When input voltage is within normal range the built in processor adjusts fan speed according to the converter module s output power For example a higher output power increases the fan speed Fan speed control can be disabled by the controller Communication Failure The protection indicator yello...
Страница 11: ...t Fan Speed Control Enable Disable HVSD Threshold Output Voltage Output Current Current Limit Setting Temperature Over Voltage Setting On Off Status Fault Alarms such as HVSD Fan Fail EEPROM Failure Protection Alarms such as Input Voltage Protection High Temperature Protection Thermal Derating Address Code Date Software Version Hardware Version Mechanical Specifications Weight 5 5 lbs Dimensions H...
Страница 12: ...er to the controller s documentation Figure 1 Local Indicator Locations Table 3 DC DC Converter Module Indicators Indicator Normal State Alarm State Alarm Cause Power Green On Off No input voltage Internal input fuse open Flashing The converter is being identified by the controller Protection Yellow Off On DC input under over voltage Moderate load sharing imbalance Converter not inserted into the ...
Страница 13: ...h mechanism located at the right side of the module Refer to Figure 2 for latch mechanism illustration 3 Push the converter module completely into the shelf 4 Push the handle into the front panel of the module Tighten the captive screw on the handle This will lock the module securely to the shelf 5 Repeat the above steps for each converter module being installed in the system 6 After the converter...
Страница 14: ...perly seated in the shelf If the current sharing imbalance still persists following the verification suggested above replace the converter module exhibiting the current imbalance Converter Module Fault Symptoms and Troubleshooting The fault indicators that can be displayed by the converter module are as follows Refer to Table 4 for a list of possible causes and corrective actions Power Indicator G...
Страница 15: ... may be blocking the fan Ventilation blocked inlet or outlet remove any object that may be blocking the inlet or outlet Ambient temperature too high or rectifier inlet too close to a heat source lower the ambient temperature or relocate the heat source Converter in ECO Standby Mode when ECO Mode is active in controller Protection Indicator Yellow Flashing Loss of communication with controller the ...
Страница 16: ...iding it in completely 5 Loosen the captive screw on the module handle Pull the handle to pivot it out of the module front panel this will also retract the latch mechanism located at the right side of the module Refer to Figure 2 for latch mechanism illustration 6 Push the converter module completely into the shelf 7 Push the handle into the front panel of the module Tighten the captive screw on t...
Страница 17: ...r s on the PC board and remove the fan s 8 Plug the power cable s of the replacement fan s into the connector s on the PC board 9 Place the new fan s in the space vacated by the old fan s ensure the fan wires and air flow arrows match the orientation of the old fan and plug it into the converter module 10 Replace the faceplate on the converter module Note that each fan has four holes in the front ...
Страница 18: ...v G 18 Figure 3 Converter Module Fan Replacement Fan Power Connectors Fans Faceplate Mounting Screws 4 Faceplate Note Verifiy arrows on fan bodies point toward rear of module Front View Position fans so that power cables exit fans here Align holes in fan with tabs on faceplate ...
Страница 19: ...Vertiv NetSure DC DC Converter Module User Manual UM1C24481500 11WA6101WB Rev G 19 This page is intentionally blank ...
Страница 20: ...VertivCo com Vertiv Headquarters 1050 Dearborn Drive Columbus OH 43085 USA UM1C24481500 11WA6101WB RG 08 17 ...