background image

FCC ID: K6630143X3D 

IC ID: 511B-30143X3D 

Alignment 

3/6

 

Vertex Standard Co,. Ltd. 

(A)  In CH70, every time you are in transmit mode, (every time you press PTT), the 

following test tone can be outputted: 

1st transmission:  1300 Hz 
2nd transmission: 2100 Hz 
3rd transmission:  No modulation 
4th transmission:  Synthetic tone of 1300 Hz and 2100 Hz  
5th transmission:  Return to 1st transmission 

(B)  Scan the channels between WX10 and EXP04 in the SCAN mode. 
 

Starting Test Mode 

Confirm that 

PWR/VOL

 switch is off, and short the TEST points (JP1001). Turn on the 

PWR/VOL

 switch while press and holding the [

DISTRESS

] and [

DW

(

IC

)] keys. 

 

Adjustment of VCO 

 

Connect the DC voltmeter to the test point (LOCK TP). 

 

Use the 

16/9

 key to set the channel to 

CH16

, adjust 

TC1001

 so that voltage on the 

TP1005

 is 1.5 V ±0.1 V in the receive mode. 

 

Use the 

16/9

 key to set the channel to 

CH16

, adjust 

TC1002

 so that voltage on the 

TP1008

 is below 3.0 V ±0.1 V in the transmit mode. 

 

Adjustment and Confirmation of Transmit Power 

Adjust power at high and low in the transmit mode, and confirm power in the specified 
bandwidth. 
-- Adjustment -- 

 

Connect the wattmeter and 50-ohm dummy load to the antenna jack. 

 

Use the [

H/L

(

NAV

)] key to set transceiver to 

high power

 and set the channel to 

CH16

With the 

PTT

 switch pressed, adjust 

VR1001

 so that RF power is 25 W. 

 

Use the [

H/L

(

NAV

)] key to set transceiver to 

low power

 and set the channel to 

CH16

With the 

PTT

 switch pressed, adjust 

VR1002

 so that RF power is 0.8 W. 

 

Adjustment of PLL Frequency 

Adjust the frequency in the transmit mode and local frequency in the receive mode. 

 

Setup the test equipment as shown below. 

 

Set the channel to 

CH16

. With the 

PTT

 switch pressed, adjust 

TC1003

 so that RF 

frequency is 156.80000 MHz ± 100 Hz. 

 

Adjustment and Confirmation of Deviation 

Adjust deviation in the transmit mode. 
-- Adjustment -- 

 

Setup the test equipment as shown below. 

Содержание VXR-9000U

Страница 1: ...make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change ci...

Страница 2: ...etermine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from ho...

Страница 3: ...t the channel to CH16 adjust TC1002 so that voltage on the TP1008 is below 3 0 V 0 1 V in the transmit mode Adjustment and Confirmation of Transmit Power Adjust power at high and low in the transmit mode and confirm power in the specified bandwidth Adjustment Connect the wattmeter and 50 ohm dummy load to the antenna jack Use the H L NAV key to set transceiver to high power and set the channel to ...

Страница 4: ...e spectrum analyzer to 159 00 MHz set SPAN to 20 00 MHz set RBW and VBW to 30 KHz and set SWP to 56 ms Adjust L1001 L1002 L1003 L1004 and L1005 until the wave form shown in below is obtained Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form varies with measuring instruments It is impotent to ta...

Страница 5: ...a Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the test equipment as shown below Press and hold the H L NAV key confirm that the position data is displayed o...

Страница 6: ... is displayed in the LCD of the test transceiver Confirm that the confirmation transceiver receives the response from the test transceiver and outputs beep Press the CALL MENU key of the confirmation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the confirmation transceiver ...

Отзывы: