background image

FCC ID: K6630143X3D 

IC ID: 511B-30143X3D 

Alignment 

2/6

 

Vertex Standard Co,. Ltd. 

 

Required Test Equipment  

 

RF Signal Generator with calibrated output level at 200 MHz   

 

Deviation Meter (linear detector)  

 

AF Millivoltmeter  

 

SINAD Meter 

 

Inline Wattmeter with 5% accuracy at 200 MHz 

 

Regulated DC Power Supply: 13.8 VDC, 10A 

 

50-ohm Non-reactive Dummy Load: 30W at 200 MHz 

 

Frequency Counter: >0.1 ppm accuracy at 200 MHz 

 

AF Signal Generator  

 

DC Voltmeter: high impedance 

 

VHF Sampling Coupler 

 

AF Dummy Load: 4 Ohms, 10 W  

 

Oscilloscope 

 

Spectrum Analyzer 

 

GX3500S Marine Transceiver 

 

Alignment Preparation & Precautions

 

A dummy load and inline wattmeter must be connected to the main antenna jack in all 

procedures that call for transmission. Correct alignment is not possible with an antenna.  

After completing one step, read the following step to determine whether the same test 

equipment will be required. If not, remove the test equipment (except dummy load and 
wattmeter, if connected) before proceeding. 

Correct alignment requires that the ambient temperature be the same as that of the 

transceiver and test equipment, and that this temperature be held constant between 20°C 
and 30°C (68°F and 86°F). When the transceiver is brought into the shop from hot or cold 
air it should be allowed some time for thermal equalization with the environment before 
alignment. If possible, alignments should be made with oscillator shields and circuit boards 
firmly affixed in place. Also, the test equipment must be thoroughly warmed up before 
beginning. 
 

Note: Signal levels in dB referred to in this procedure are based on 0 dBµ = 0.5 µV (closed 
circuit). 

 

Overview of Test Mode 

The test mode has been build in the microprocessor in order to adjust and confirm the 

performance of transceiver. 

The purpose is to adjust transceiver simply and to confirm the performance of 

transceiver smoothly. 

 

Содержание VXR-9000U

Страница 1: ...make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change ci...

Страница 2: ...etermine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from ho...

Страница 3: ...t the channel to CH16 adjust TC1002 so that voltage on the TP1008 is below 3 0 V 0 1 V in the transmit mode Adjustment and Confirmation of Transmit Power Adjust power at high and low in the transmit mode and confirm power in the specified bandwidth Adjustment Connect the wattmeter and 50 ohm dummy load to the antenna jack Use the H L NAV key to set transceiver to high power and set the channel to ...

Страница 4: ...e spectrum analyzer to 159 00 MHz set SPAN to 20 00 MHz set RBW and VBW to 30 KHz and set SWP to 56 ms Adjust L1001 L1002 L1003 L1004 and L1005 until the wave form shown in below is obtained Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form varies with measuring instruments It is impotent to ta...

Страница 5: ...a Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the test equipment as shown below Press and hold the H L NAV key confirm that the position data is displayed o...

Страница 6: ... is displayed in the LCD of the test transceiver Confirm that the confirmation transceiver receives the response from the test transceiver and outputs beep Press the CALL MENU key of the confirmation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the confirmation transceiver ...

Отзывы: