15
VX-1400 O
PERATING
M
ANUAL
B
ASE
S
TATION
I
NSTALLATION
DC Power Connections
For base station installations, Vertex Standard recommends the use of the optional
FP-
1030A
AC Power Supply. The
FP-1030A
provides a regulated 13.8 V DC supply at up to
25-Ampere.
Other models of DC power supplies may be used with the
VX-1400
, but the 13.8 V DC
input voltage, 23-Ampere current capability, and DC cable polarity guidelines described
previously must be strictly followed.
If you are connecting the
FP-1030A
with the
VX-1400
for the first time, before
connecting power check the label in the rear of the
FP-1030A
which indicates the
AC mains voltage for which the supply is currently set.
C
AUTION
!
Permanent damage can result if improper supply voltage is applied to this trans-
ceiver. Your warranty does not cover damage caused by application of AC, reversed polar-
ity DC, or DC outside of the specified range of 13.8 V ±15%. If using a power supply
other than the
FP-1030A
, ensure that the DC supply connector to the transceiver matches
the
VX-1400
wiring configuration. Other manufacturers may utilize power supplies with
a physically matched connector that is wired differently; this will cause serious damage to
the
VX-1400
transceiver!
I
NSTALLATION
Supplied DC Cable
V
A
0
0
5
5
10
20
15
30
20
40
CONTINUOUS CURRENT 25A
O VE RLO AD
POWER
ON
OFF
FP-1030A
VX-1400
RED
BLACK
FUSE: 25A