FCC ID: K6630173X3D
IC ID: 511B-30173X3D
Alignment
5/5
Vertex Standard Co,. Ltd.
Confirmation of Weather Alert Tone
In the weather channel mode, when transceiver receives the specific emergency tone
(1050 Hz), weather alert tone will be output (Weather Alert Operation). The Weather Alert
mode will be active when a NOAA weather channel is in memory and radio is in memory
scan or P-scan mode.
Connect the standard signal generator (SSG) to the antenna jack.
Squelch position set to tight.
Press the
SCAN
key and start to Memory Scan mode.
Set the SSG to 163.275 MHz (WX10) and output level of the SSG to 20 dBµV, ±3.0
kHz deviation with 1050 Hz tone modulation.
Set the output of the SSG to ON.
Confirm that the channel of transceiver stops at WX10 and the transceiver outputs the
weather alert tone (1050 Hz).
Confirmation of receiver NMEA data
Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and
display it to the LCD of the transceiver.
NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver’s
option connector and LCD of transceiver will show data.
Setup the test equipment as shown below.
Press and hold the
H/L
key, confirm that the position data is displayed on the LCD of
transceiver.
Confirmation of DSC Operation
Prepare the confirmation transceiver (GX3500S).
Input below data to the confirmation transceiver in advance.
-
Input “TEST” to NAME of INDIVIDUAL DIRECTORY
-
Input “123456789” to MMSI of INDIVIDUAL DIRECTORY
-
Input “123456780” to local MMSI
-
Channel 13 in U.S.A. mode
Setup the test transceiver as follows:
-
Channel 21 in U.S.A.
In 3 seconds, send the INDIVIDUAL CALL from the confirmation transceiver.
Confirm that the test transceiver receives the INDIVIDUAL CALL from the confirmation
transceiver and outputs the beep.
Press the
CALL/SET
key of the test transceiver and turn off the beep.
Simultaneously, confirm that “123456780” of confirmation transceiver’s MMSI is
displayed in the LCD of the test transceiver.
Confirm that the confirmation transceiver receives the response from the test
transceiver and outputs beep.
Press the
CALL/SET
key of the confirmation transceiver and turn off the beep.
Simultaneously, confirm that “TEST” of test transceiver’s MMSI is displayed in the LCD
of the confirmation transceiver.