FCC ID: K66FT-857
Operating Manual
Vertex Standard Co., Ltd.
78
Function: The choice of the equipment which connects to the MIC jack.
Available Values: NOR/RMT/CAT
Default: NOR
NOR:
Normal Microphone.
RMT:
Not available at this time.
CAT:
CAT system: if you are using the optional FC-30 antenna tuner, you can still use the CAT system by connecting
the serial Data cable to the MIC jack.
MENU MODE No
x
060 [MTR ARX SEL]
Function: Select the meter display configuration while the transceiver is receiving.
Available Values: SIG, CTR, VLT, N/A, FS, OFF
Default: SIG
SIG: Indicates the incoming signal strength.
CTR: Discriminator center meter.
VLT: Indicates the battery voltage.
N/A:
Not available at this time.
FS:
Applies a calibration signal (1 mA for full scale) at the METER Jack on the transceiver bottom, for adjustment of
an external meter’s calibration.
You may adjust the external potentiometer in your metering system so that the external meter reading is full scale.
OFF: Disables the meter.
MENU MODE No
x
061 [MTR ATX SEL]
Function: Selects the meter display configuration while the transceiver is transmitting.
Available Values: PWR, ALC, MOD, SWR, VLT, N/A, OFF
Default: PWR
PWR:
Indicates the relative transmit power.
ALC:
Indicates the relative Automatic Level Control voltage.
MOD:
Indicates the deviation level.
SWR:
Indicates the Standing Wave Ratio (forward:reflected).
VLT:
Indicates the battery voltage.
N/A:
Not available at this time.
OFF:
Disables the meter.