FCC ID: K66FT-857
Operating Manual
Vertex Standard Co., Ltd.
63
037
DIG GAIN
Adjusts the audio input level from terminal equipment during
DIG (Digital) mode operation.
0 ~ 100
50
038
DIG MODE
Selects the mode and sideband in the DIG (Digital) mode.
RTTY-L/RTTY-U/
PSK31-L/
PSK31-U/USER-L/
USER-U
RTTY-L
039
DIG SHIFT
Defines the carrier frequency offset during DIG (USER-L or
USER-U) mode operation.
–3000 ~ +3000 Hz
0 Hz
040
DIG VOX
Sets the gain of the VOX circuitry’s input level for the DIG
mode.
0 ~ 100
0
041
DISP COLOR
Selects the illumination color for each operating status.
–
–
042
DISP CONTRAST
Setting of the display contrast level.
0 ~ 13
5
043
DISP INTENSITY
Setting of the display brightness level.
0 (Dim) ~
3 (Bright)
3
044
DISP MODE
Sets up the LCD Lamp mode.
OFF/AUTO1/
AUTO2/ON
AUTO2
045
DSP BPF WIDTH
Setting of the bandwidth for the DSP CW audio filter.
60/120/240 Hz
240 Hz
046
DSP HPF
CUTOFF
Adjusts the low-cut characteristics of the DSP HPF filter.
100 ~ 1000 Hz
100 Hz
047
DSP LPF
CUTOFF
Adjusts the high-cut characteristics of the DSP LPF filter.
1000 ~ 6000 Hz
6000 Hz
048
DSP MIC EQ
Sets the DSP microphone equalization pattern.
OFF/LPF/HPF/
BOTH
OFF
049
DSP NR LEVEL
Setting of the degree of DSP Noise Reduction.
1 ~ 16
8
050
EMERGENCY
Enables Tx/Rx operation on the Alaska Emergency Channel,
5167.5 kHz.
ON/OFF
OFF
051
FM MIC GAIN
Adjusts the microphone gain level for the FM mode.
0 ~ 100
50
052
FM STEP
Selects the tuning steps for the MEM/VFO CH knob in the
FM mode.
5/6.25/10/12.5/
15/20/25/50 kHz
*2
053
HOME-->VFO
Enables/disables the moving of HOME channel data to the
VFO.
ON/OFF
ON
054
LOCK MODE
Selects the operation of the front panel’s LOCK key.
DIAL/FREQ/
PANEL/ALL
DIAL