EPM-31 Hardware Reference Manual
vi
M
OUNTING
S
UPPORT
The single board computer must be supported at all four mounting points to prevent excessive
flexing when expansion modules are attached and removed. Flex damage caused by excessive
force on an improperly mounted circuit board is not covered under the product warranty. See
page 15 for more details.
E
ARTH
G
ROUND
R
EQUIREMENT
All mounting standoffs should be connected to earth ground (chassis ground). This provides
proper grounding for EMI purposes. Figure 1 shows the locations of the board’s mounting holes.
All mounting holes identified in Figure 1 must be connected to earth ground.
Figure 1. Attaching the EPM-31 to Earth Ground