Thermal Considerations
65
VL-EPU-4012 Hardware Reference Manual
Heat Sink with Fan Considerations:
The heat sink and fan combination cools the CPU when it is running in high temperature
environments, or when the application software is heavily utilizing the CPU or video
circuitry. The fan assists in cooling the heat sink and provides additional air movement
within the system.
Integrator’s Note:
The ambient air surrounding the EPU-4012 needs to be maintained
at 85 °C or below.
EPU-4012 Thermal Characterization
The EPU-4012 board underwent the following thermal characterization tests:
Test Scenario 1: Dual core EPU-4012-EAP
Test Scenario 2: Quad core EPU-4012 EDP
The test results reflect the test environment within the temperature chamber used. This particular
chamber has airflow of about 0.5 linear meters per second (~100 linear feet per minute). Thermal
performance can be greatly enhanced by increasing the airflow beyond 0.5 linear meters per
second.
The system power dissipation is primarily dependent on the application program; that is, its use
of computing or I/O resources. The stress levels used in this testing are considered to be at the
top of the range of a typical user’s needs.
Thermal Test Results
Test Scenario 1: Dual Core EPU-4012-EAP without HDW-415 fan
Table 23. Dual Core Hardware Setup
Test Platform:
EPU-4012
s/n:
172465
BIOS:
1009
BIOS Trip
Points:
Critical - 125C, Hot - 119C, Passive - 111C, Active - 60C
Heat Sink
Configuration:
Hardware
Configuration:
1x DP monitor, 1x USB keyboard & mouse, 1x SATA HDD (6Gbs), 1x USB3
loopback, 2x USB2 loopback, 1x MPEe-E5E, 4x network
Software:
Windows 10 v1607 b14393.0, Intel Passmark BurnIn Test v9.0 Pro b1013
Note:
mPCIe slots were tested with 1 slot populated.