Configuration and Setup
17
VL-EPU-4012 Hardware Reference Manual
Jumper Blocks
Jumper As-Shipped Configuration
Figure 6. Jumpers As-Shipped Configuration
Jumper Configuration Summary
Table 1: Jumper Block Configurations
Jumper
Block
Pins
Function
Description
V1
1-2
COM2 Endpoint
Termination
Jumper In: Endpoint termination (for RS-485 or RS-422)
Jumper Out: Not terminated (RS-232) (default)
3-4
COM1 Endpoint
termination
Jumper In: Endpoint termination (for RS-485 or RS-422)
Jumper Out: Not terminated (RS-232) (default)
V2
1-2
COM3 Endpoint
Termination
Jumper In: Endpoint termination (for RS-485 or RS-422)
Jumper Out: Not terminated (RS-232) (default)
3-4
COM4 Endpoint
termination
Jumper In: Endpoint termination (for RS-485 or RS-422)
Jumper Out: Not terminated (RS-232) (default)
V3
1-2
Primary/Backup
BIOS Select
Jumper In: Use Backup BIOS
Jumper Out: Use Primary BIOS (default)
V4
1-2
Backup BIOS
Write Protect
Jumper In: Backup BIOS is write-protected
Jumper Out: Backup BIOS is not write-protected (default)