4
Windsor High Efficiency Wood Stove
30005128
D
A
E
B
8”(203 mm)
*18” (457 mm)
8”
8”
F
C
F
S
ID
E
W
A
LL
* CANADA **U.S.A
S
ID
E
W
A
LL
**16” (406 mm)
BACK WALL
BACK WALL
C
&,//202/4%#4)/.
34
CLEARANCES
installation
Figure 2
Clearance to Combustible Materials
2. Select the proper location for the stove. These appli-
ances must not be installed any closer than the mini-
mum clearance to combustible materials. (Fig. 2) The
stove must be installed on a noncombustible surface
as shown on Page 7, Figure 4.
3. If noncombustible materials have been installed on the
walls, obtain the minimum clearances from either the
manufacturer of these materials or the local building
inspector’s office.
4. Install the refractory bricks. (Fig. 3) Be sure all bricks
are in place.
5. Install the stovepipe INSIDE the flue collar on the top
of the stove between the stove and chimney.
6.
Do Not
use a grate to elevate the fire.
Unit must be placed on a noncombustible floor protection
equivalent to 3/8” millboard. Floor protector must have min. R
value of .893. Consult your local building authorities for further
information.
Contact your local building inspector prior to installa-
tion. A permit may be required in your area.
This Homeowner’s Manual describes the installation
and operation of the models: WR1000L02, WR1500L02,
WR2000L02 non-catalytic wood heater. This heater meets
US Environmental Protection Agency’s emission limts for
wood heaters. Under specific conditions this heater has
been shown to deliver heat at the rates shown in Chart
1. Remove all parts from inside the stove body.
failure to follow the minimum clearance requirements
and noncombustible surface requirements may result
in an unsafe installation.
WR1000 Series Clearances to Combustibles
A
B
C
D
E
F G
Single wall
12” 12
Z\x
” 7” 19
Z\x
” 15”
15”
56”
Connector
(305) (318) (178) (405) (381) (381) (1422)
Double wall 8
Z\x
”
8”
5
Z\x
” 15
Z\x
” 10”
13”
56”
Connector
(216) (203) (140) (394) (254) (330) (1422)
Heat output Ranges
Model
output Range BtU/hr
WR1000L02
10,600 to 26,100
WR1500L02
10,370 to 29,301
WR2000L02
11,800 to 32,300
WR1500 Series Clearances to Combustibles
A
B
C
D
E
F G
Single wall
11
Z\x
”
9”
7”
21” 11
Z\x
” 18” 54
Z\x
”
Connector
(292) (229) (178) (533) (292) (457) (1384)
Double wall
6”
6”
4”
15”
8”
14” 54
Z\x
”
Connector
(152) (152) (102) (381) (203) (356) (1384)
G
34
CEILINGCLEARANCES
Ceiling
Floor
ST1033
ST1032
WR2000 Series Clearances to Combustibles
A
B
C
D
E
F G
Single wall
15”
10”
9” 24
Z\x
” 13” 19
Z\x
” 54”
Connector
(381) (254) (229) (822) (325) (495) (1372)
Double wall
14”
10”
8”
23”
13”
18”
54”
Connector
(356) (254) (203) (584) (325) (457) (1372)