83D4009
VLI31 Fireplace Insert
5
FP2677
VLI31 controls
PRODuct FeAtuReS
•
This appliance has been certified for use with either
natural or propane gas. Refer to the appropriate data
plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
PRODuct SPecIFIcAtIONS
Figure 1 -
VLIDV Series Fireplace Insert Controls
Command
Center
hIGh eLeVAtIONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installation at elevations above
4,500 feet (1,370 m).
GAS PReSSuReS
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
Max.Input Min. Input Orifice
Model
Fuel
Btu/h
Btu/h
Size
VLI31DVNTSC Nat.
3,000
,500
#35
VLI31DVPTSC
LP
3,000
5,500
#51
GAS SPecIFIcAtIONS & ORIFIce SIZe
FP677
Gas Shut
Off