12
Save These Instructions
Vermont Castings • Aspen 1920 Owner's Manual_R32 • 08/17
When:
A
= 9" (229 mm) Max.
B
= 22-1/2 (572 mm) Min.
A
= 7-1/2" (191 mm) Max.
B
= 21" (533 mm) Min.
A
= 6" (152 mm) Max.
B
= 19-1/2" (495 mm) Min.
A
= 4-1/2" (114 mm) Max.
B
= 18" (457 mm) Min.
A
= 3" (76 mm) Max.
B
= 16-1/2" (419 mm) Min.
A
= 1-1/2" (38 mm) Max.
B
= 15" (381 mm) Min.
ST252a
mantel clrncs
12/14/99 djt
Min. 15"
(381mm)
1
1
⁄
2
"
(38mm)
Max. 9"
(229mm)
22
1
⁄
2
"
(572mm)
A
B
Figure 4.8
- Mantel and trim clearances.
Unprotected
Surface
Protected
Surfaces
(NFPA 211)
A
Minimum Width
62"
158 cm
46"
117 cm
B
Maximum Depth
48"
122 cm
48"
122 cm
C
Ceiling Above
Stove Top
36"
92 cm
18"
46 cm
ST254
alcove clearances
12/99
Figure 4.10
- Alcove Specifications.
B
A
C
Fireplace Clearances:
A fireplace installation requires special clearance between
the side of the stove and the right and left walls, the side of
the stove and the decorative side trim on the fireplace face,
and the top of the stove and the mantel.
Maximum Mantel depth (A, Figure 4.8) of a combustible
mantel is 9” (230 mm). At that depth, the clearance to the
stove top (B) must be a minimum of 22-1/2" (572 mm).
Top Trim (C) protruding less than 1
-1/2
" (38 mm) from the
face of the fireplace must be a minimum of 12" (305 mm)
from the stove top. This clearance may not be reduced by
shielding.
For every 1
-1/2
" (38 mm) increment that the trim or mantel
extends in depth, the clearance from the stove top must also
be increased by 1
-1/2
" (38 mm).
Side Trim must have a minimum clearance of 8" (203 mm),
measured from the stove's top edge. (D, Figure 4.9)
Alcove Clearances:
The Aspen is approved for installation into an alcove constructed
to maintain the clearances diagramed in Figure 4.10.
B
Mantel
22-1/2" (572 mm)
C
*Top Trim
12" (305 mm)
D
Side Trim
8" (203 mm)
*Material is less than 1-1/2" (38 mm) Thick
Figure 4.9
- Mantel and trim clearances.
ST253a
aspen
trim clearances
12/15/99 djt
C
D
D
B