47
20306759
Radiance
®
Direct Vent Gas Heater
HI
LO
HI
LO
LP Configuration
Natural Gas
Configuration
CO141
O-ring configuration
6/07
Red O-ring Visible
Red O-ring NOT Visible
CO141
Fig. 77
8. Verify that if the conversion is from NG to LP, the screw
must be reassembled with the red o-ring visible. (Fig-
ure 77)
9. Replace the black protection cap.
FUEL CONVERSION
NOTE: Check that also the pilot and main burner
injectors are appropriate for the gas type.
ST350
Jefferson
air shutter adj
3/20/00 djt
Pilot
ST916
Fig. 78 Locate pilot.
Pilot Orifice Conversion
• Locate pilot. (Figure 78)
•
Replace pilot orifice.
• Remove pilot hood by lifting up. (Figure 79) Do not re-
move the snap ring to remove the pilot hood.
NOTE: It is not necessary to remove the pilot tube
for conversion.
•
Remove pilot orifice with Allen wrench. (Figure 80)
•
Install the conversion orifice.
Fig. 79 Remove pilot hood.
CO105a
gas conversion
Pilot
1/28/00 djt
Pilot hood
Pilot bracket
Fig. 80 Remove pilot orifice.
CO106a
DV360/580
Gas Conversion
Pilot2
1/28/00 djt
Allen wrench
Index tab
Snap ring
• Reinstall pilot hood. Be sure to align hood with index
tab.