TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
27
Fault Finding Chart 5
NO
5
Is
burner gas
pressure within
spec?
YES
NO
Refer to section on „Checking Gas Inlet
Pressure‟. Refer to Specification Table
for gas pressures.
Replace gas valve.
NO
Is pilot
flame adjusted
correctly?
Adjust pilot flame.
NO
Is
blocked
flue switch
open?
YES
YES
NO
Refer to section on „Checking Burner
Gas Pressure‟. Refer to Specification
Table for gas pressures.
Are
thermopiles
working?
YES
NO
Replace gas valve.
Advise customer.
Refer to section on
„Adjusting the Pilot Flame‟.
Does
burner go out
only when local/remote
switch is set to
„remote‟?
NO
YES
The local/remote selector
switch is located on the
gas valve
Replace faulty thermopile(s).
Are burner
injectors
blocked?
Is
burner feed pipe
blocked?
Is
burner manifold
blocked?
NO
NO
Clean or replace
burner injectors.
NO
Clean or replace burner
manifold feed pipe.
Remove blockage from
burner manifold.
YES
YES
YES
Remote
controller
setting
5.1
5.2
ON (manual)
OFF
AUTO
The remote controller must
be set to
„On‟ or „Auto‟ mode
for the burner to operate.
Does
gas valve LED
indicate 3 or 8
flashes?
Is gas
inlet pressure
within spec?
2.1
YES
YES
Tests 3 & 4
2.2
Test 2A for LHEC30
or
Test 2B for RFSDV34