Operational Flow Chart
Plug In
Power On
Initial
check
normal?
Fault rectified
Isolate Power
Thermopile fault
LED 3 Flash
Gas valve fault
LED 8 Flash
NO
Pilotstat knob manually
turned to „Pilot‟ then
depressed & held in
Pilot gas valve open
Piezo igniter manually
pushed generating
spark at igniter
Did
Pilot
ignite?
NO
Pilotstat knob released
LED 1 flash
Did
pilot go
out?
YES
Local/Remote selector
switch manually set to
„Local‟ (if on „Remote)
3 seconds
later (hot start)
to 1 min later
(cold start)
Pilotstat knob manually
turned to „on‟
Burner gas valve
fully open
Fan on full
Is
LED indicating
1 flash?
Wait until LED
stops indicating
1 flash
YES
NO
YES
YES
NO
Pilotstat knob manually
turned to „off‟
Pilot gas valve
closed
Burner gas valve
closed
Fan off
Manual Off Operation
On Operation
E
A
Pilotstat knob manually
depressed & held in
Pilot gas valve
closed
Burner (gas valve) on
previous remote control setting
Fan on previous remote
control setting
Remote controller fan
speed selected from 0 - 6
Does
thermopile 1
generate > 500
mV?
Does
thermopile 2
generate > 280
mV?
YES
Is
blocked
flue switch
closed?
YES
YES
Pilot gas valve
closed
Burner gas valve
closed (if open)
Fan off (if on)
Pilotstat knob manually
turned to „off‟
A
E
NO
NO
NO
Thermopile 1 >
500mV
Thermopile 2 >
280mV
Remote controller operation
– Gas valve Selector switch
on „Remote‟
Remote controller operation
– Gas valve Selector switch
on „Local‟
Gas valve
local/remote selector
switch manually set to
„Remote‟?
C
B
YES
NO
C
B
Gas control valve
alters fan motor
voltage to new setting
D
Remote
Controller
Mode?
Remote controller flame
height selected from 0 - 6
Gas control valve
modulates burner gas
valve to new setting
Remote controller fan
speed selected from 0 - 6
Gas control valve
alters fan motor
voltage to new setting
D
Room
temp > set
temp?
Burner gas valve
closed
Fan off
Burner gas valve
open (level 1
– 6)
Fan on (level 1
– 6)
NO
Fan override
activated?
NO
YES
Fan override can
be activated by
pressing the fan &
then up or down
arrow buttons
Gas control valve
alters fan motor
voltage to new setting
Room
temp > set
temp?
YES
Burner gas valve
closed
Burner gas valve
open (level 1
– 6)
NO
YES
Auto
On
(Manual)
Blocked flue fault rectified
(if applicable)
No remote controller
operation preformed
Count
down timer
on?
Burner gas valve
closed
NO
YES
No remote controller
operation preformed
Remote
controller reset to
Auto or on?
Count down timer
reaches „0‟
Fan off
YES
NO
Remote controller
set to „off‟
Remote Controller
Off Operation
Burner gas valve
closed
Fan off
Remote
controller reset to
auto or on?
NO
YES
(1) Note:
Initial check
is performed
whilst ever
log fire is
operating
(1)