TM036 Vermont Gas Fireplace & Gas Log Fire Service Instructions REV: A
D.O.I: 17/01/2008
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
13
On (Manual) Mode
Press and release the „Mode‟
button until „On‟ is displayed on
the controller.
After a two second delay the
burner and fan will turn on and
operate on the previously used
settings. The information shown
on the diagram opposite will be
displayed
on
the
remote
controller display.
To adjust the main burner flame level press and release the flame button. The flame icon
will be displayed along with the current flame level setting. The flame level setting can then
be adjusted from 0 to 6 in increments of 1 by pressing and releasing the up or down arrow
buttons. If the flame level is set on „0‟ the burner will turn off however the pilot will remain
lit.
After a two second delay from the operation of any button the controller will accept the new
setting and revert to the previous display. The flame level will then change to the new
setting.
Likewise, to adjust the fan speed press and release the fan button. The fan icon will be
displayed along with the current fan speed setting. The fan speed setting can then be
adjusted from 0 to 6 in increments of 1 by pressing and releasing the up or down arrow
buttons. If the fan level is set on „0‟ the fan will turn off.
After a two second delay from the operation of any button the controller will accept the new
setting and revert to the previous display. The fan level will then change to the new setting.
Auto Mode
Press and release the „mode‟
button until „Auto‟ is displayed.
After a two second delay the
information
shown
on
the
diagram
opposite
will
be
displayed
on
the
remote
controller display.
If the room temperature is higher
than the set point temperature the burner and fan will not turn on (or will turn off if already
on).
The flame and fan levels will both indicate „0‟ (off) and will not operate however the
gas valve and pilot will remain on.
To adjust the set point temperature press and release an up or down arrow button. The set
point temperature will then be displayed.
The set point temperature can then be adjusted in increments of 0.5 degrees by pressing
and releasing the up or down arrow buttons.
After a two second delay from the operation of any button the controller will accept the new
setting and revert to the previous display.