background image

35

Dutchwest Direct Vent / Natural Vent Gas Heater

30001935 

LIMITED LIFETIME WARRANTY 

PRODUCT COVERED BY THIS WARRANTY
All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner.

BASIC WARRANTY

CFM Corporation Company (hereinafter referred to collectively as the 
Company) warrants that your new Dutchwest Gas Fireplace/Stove is 
free from manufacturing and material defects for a period of one year 
from the date of purchase, subject to the following conditions and 
limitations.

EXTENDED LIFETIME WARRANTY

The heat exchanger, where applicable, and combustion chamber of 
every Dutchwest gas product is warranted for life against through 
wall perforation. All appliances equipped with an Insta-Flame Ce-
ramic Burner have limited lifetime coverage on the ceramic burner 
plaque. Warrantees are made to the original owner subject to proof 
of purchase and the conditions and limitations listed on this Warranty 
Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a 
period of three years.

Note:

 On porcelain enamel finished external parts and accessories 

The Company offers no Warranty on chipping of enamel surfaces. 
Inspect all product prior to accepting it for any damage to the enamel.
The salt air environment of coastal areas or a high humidity environ-
ment can be corrosive to the porcelain enamel finish. These condi-
tions can cause rusting of the cast iron beneath the porcelain enamel 
finish, which will cause the finish to flake off.
Dye lot variations with replacement parts and/or accessories can oc-
cur and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. 
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to 
environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be 
cleaned with Lemon oil only. Brass cleaners cannot be used.  Mortar 
mix and masonry cleaners may corrode the brass finish.  The Company 
will not be responsible for, nor will it warrant any brass parts which are 
damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and 
mechanical components of the burner assembly are covered for one 
year. All steel tube burners are warranted for one year.
ACCESSORIES: Unless otherwise noted all components and CFM 
Corporation company supplied accessories are covered for a period of 
one year.

CONDITIONS AND LIMITATIONS

•  This new Dutchwest product must be installed by a competent, 

authorized, service contractor. A licensed technician, as prescribed 
by the local jurisdiction must perform any installation/service work. 
It must be installed and operated at all times in accordance with the 
Installation and Operating instructions furnished with the product. 
Any alteration, willful abuse, accident, or misuse of the product shall 
nullify this warranty.

•  This warranty is non-transferable, and is made to the original owner, 

provided that the purchase was made through an authorized supplier 
of the Company.

•  The customer must pay for any Authorized Dealer in-home travel 

fees or service charges for in-home repair work. It is the dealers op-
tion whether the repair work will be done in the customer’s home or in 
the dealer’s shop.

•  If upon inspection, the damage is found to be the fault of the manu-

facturer, repairs will be authorized at no charge to the customer parts 
and/or labor.  

•  Any part and/or component replaced under the provisions of this 

warranty is covered for six months or the remainder of the original 
warranty, whichever is longest.

•  This warranty is limited to the repair of or replacement of part(s) 

found to be defective in material or workmanship, provided that such 
part(s) have been subjected to normal conditions of use and service, 
after said defect is confirmed by the Company’s inspection.

•  The company may, at its discretion, fully discharge all obligations 

with respect to this warranty by refunding the wholesale price of the 
defective part(s)

•  Any installation, labor, construction, transportation, or other related 

costs/expenses arising from defective part(s), repair, replacement, or 
otherwise of same, will not be covered by this warranty, nor shall the 
Company assume responsibility for same. Further, the Company will 
not be responsible for any incidental, indirect, or consequential dam-
ages except as provided by law.

• 

SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMI-
TATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR 
LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, 
SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR CIR-
CUMSTANCES.  THIS WARRANTY GIVES YOU SPECIFIC RIGHTS 
AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

•  All other warranties-expressed or implied- with respect to the product, 

its components and accessories, or any obligations/liabilities on the 
part of the Company are hereby expressly excluded.

•  The Company neither assumes, nor authorizes any third party to as-

sume on its behalf, any other liabilities with respect to the sale of this 
CFM Corporation product

•  The warranties as outlined within this document do not apply to chim-

ney components or other non CFM Corporation accessories used in 
conjunction with the installation of this product..

•  Damage to the unit while in transit is not covered by this warranty but 

is subject to claim against the common carrier. Contact the dealer 
from whom you purchased your fireplace/stove (do not operate the 
appliance as this might negate the ability to process the claim with 
the carrier).

•  The Company will not be responsible for:
  a)  Down drafts or spillage caused by environmental conditions such 

as near-by trees, buildings, roof tops, hills, or mountains.

  b)  Inadequate ventilation or negative air pressure caused by me-

chanical systems such as furnaces, fans, clothes dryers, etc.

•  This warranty is void if:
  a)  The fireplace has been operated in atmospheres contaminated by 

chlorine, fluorine, or other damaging chemicals.

  b)  The fireplace has been subjected to prolonged periods of damp-

ness or condensation

  c)  Any damages to the fireplace, combustion chamber, heat 

exchanger or other components due to water, or weather damage, 
which is the result of but not limited to, improper chimney/venting 
installation.

  d)  Any alteration, willful abuse, accident, or misuse of the product 

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1) Contact your supplier.  Make sure you have your warranty, your 

sales receipt, and the model/serial number of your  CFM Corpo-
ration product.

2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.

Содержание Dutchwest 2465

Страница 1: ...ANUAL BEFORE INSTALLING AND USING APPLIANCE INSTALLER CONSUMER SAFETY INFORMATION FOR YOUR SAFETY Installation and service must be performed by a quali ed installer service agency or the gas supplier...

Страница 2: ...12 Install the Optional Fan 13 Venting System Assembly Direct Vent 14 Install Vent Adapter Pipe CFM Vent Components 14 Install Vent Adapter Pipe Simpson Dura Vent Components 15 Side Wall Termination A...

Страница 3: ...the room for combustion and vent the exhaust vertically through the roof to the atmo sphere This appliance is approved for bedroom installations in the U S and Canada This appliance may be installed...

Страница 4: ...utchwest stove is shipped from the factory as a Direct Vent Gas Heater This heater may be convert ed into a Natural Vent unit in the eld If a Natural Vent heater is desired the Z31D00 FSDHAG Draft Hoo...

Страница 5: ...her most often The vent system requirements NOTE We do not recommend the use of wallpaper next to this stove Over time radiant heat may cause the wallpaper to shrink or may adversely affect the binder...

Страница 6: ...ST131c Dutchwest wall thimble 5 15 03 djt A A Effective Minimum Wall Thimble 57 1461 mm CFM Pipe Centerline 53 1359 mm Simpson DuraVent Pipe ST131c Fig 5 Minimum wall thimble centerline Wall and Ceil...

Страница 7: ...ncial and or local authorities having jurisdiction for installations at elevations above 4 500 feet 1 370m WARNING Improper installation adjustment alteration service or maintenance can cause in jury...

Страница 8: ...ning the installation consider the location of the vent terminal and clearances Some of the most common clearances to keep in mind are shown in Fig ure 10 Important All vent clearances must be maintai...

Страница 9: ...als shall not be recessed into a wall or siding Horizontal venting must be installed on a level plane without an inclining or declining slope There must not be any obstruction such as bushes garden sh...

Страница 10: ...tor assy I Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air i...

Страница 11: ...ctor plate supplied with the stove is not used Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors G Combustible 6 15...

Страница 12: ...the Wall Vent Kit 7TFSMSK 1 90 Degree Elbow CG 1 24 Straight pipe CG 1 36 Straight pipe CG 1 Side Wall Termination 1 Firestop 1 Zero clearance sleeve 1 Hardware package 1 Finishing plate CG 1 Finishi...

Страница 13: ...onents 2 Remove the rear skirt insert panel at the bottom of the Rear Skirt Fig 13 and fasten the blower as sembly to the rebox back with the two Phillips pan head bolts originally installed in the re...

Страница 14: ...est restictor plate 5 15 03 ST759 Fig 16 Install the restrictor plate only if required for the vent ing con guration Refer to Page 8 2 Attach Inner Starter Pipe found in with the logset to the next se...

Страница 15: ...Simpson DuraVent install inner adapter pipe ST763 DW dura vent attach outer assy ST763 Fig 21 Simpson DuraVent install outer adapter pipe Side Wall Termination Assembly 1 Locate the vent opening on th...

Страница 16: ...equired if installing a second 90 elbow Fig 25 8 Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve Seal the joint inside the wall plate...

Страница 17: ...d Bracket Wall Screws and Anchors Waterproof Seal Around Pipe ST219 Fig 29 Use extension brackets to mount snorkel against recessed wall If the foundation is recessed use extension brackets not suppli...

Страница 18: ...types of B vent pipe use components from one maker or the other Follow the vent component maker s instructions exactly The heater will also accept standard or enam elled 7 150mm diameter pipe around...

Страница 19: ...the rebox 5 Loosely sprinkle the lava rocks directly on top of the burner in front of and between the decorative grate and the right and left logs Use the lava rock to cover brackets on the burner Fig...

Страница 20: ...inlet supply for adjustment of 5 5 w c In order to connect Propane use a tting with 3 8 NPT nipple on the valve side and 1 2 propane gas supply line with an input of 28 000 BTUs at a manifold pressure...

Страница 21: ...which holds the injectors at a 90 angle to the base Fig 40 This keeps the ori ces aligned with tubes on the inside of the burner Failure to do so could affect the ame appearance and performance of the...

Страница 22: ...e 3 8 locking nut provided Fig 43 The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body Position the front about 3 dow...

Страница 23: ...s sistance Do not operate the heater until the pilot ame is correct Follow regular maintenance procedures as described on Page 30 ST769 Dutchwest pilot location 5 15 03 djt Pilot Assembly ST769 Fig 45...

Страница 24: ...these instruc tions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF Y...

Страница 25: ...e thermocouple operates the pilot ame Tighten the thermocouple The thermopile operates the main valve ON and OFF Clean and or adjust pilot for maximum ame impingement on thermocouple and thermopile Tu...

Страница 26: ...on a at padded surface such as a coun ter protected by a towel 4 Remove the logset from the rebox 5 Remove the rear log bracket by unfastening the screw Fig 49 6 Remove the right and left log bracket...

Страница 27: ...spring and diaphragm assembly FC107 D E F FC108 SIT regulator conversion 10 03 OF F P I L O T O FC108 Fig 52 Replace regulator CO105a gas conversion Pilot 1 28 00 djt Pilot Hood Pilot Bracket CO105a...

Страница 28: ...he tubes inside burner Failure to do so could affect the ame appearance and performance of the unit 22 Place conversion label on valve 23 Reinstall the right and left log bracket assembly 24 Reinstall...

Страница 29: ...ature stove paints available through your local dealer to touch up areas as needed Clean areas to be painted with a wire brush and be sure to cover the logs burner and valve assembly glass and frame a...

Страница 30: ...g properly check the ames periodically to con rms they match Figure 61 The ames will be blue during the rst 15 20 minutes of operation and will gradually turn to yellow after that Do not use your stov...

Страница 31: ...t circuit NOTE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE SF 2 200 WIRE OR ITS EQUIVALENT Thermocouple Safety Limit Switch Valve ST665 Sa...

Страница 32: ...e changes in design materials speci cations prices and discontinue colors and products at any time without notice Dutchwest Direct Vent Natural Vent Gas Heater Models 2465 2466 Ref Description Dutchwe...

Страница 33: ...T24 10001297 20 Nut Electrode SIT 0 974 144 57886 21 Tubing Pilot w Fittings 1 8 x 24 10001296 22 Burner Housing Assembly NG LP 20002214 23 Grate Burner JDV 20002167 24 Ashdoor Handle Assy E V WSI 500...

Страница 34: ...itself does not require regular maintenance however periodic cleaning of the fan and the surround ing area is required Installation Refer to Page 13 for installation instructions Remote Controls The r...

Страница 35: ...vel fees or service charges for in home repair work It is the dealers op tion whether the repair work will be done in the customer s home or in the dealer s shop If upon inspection the damage is found...

Страница 36: ...Ef ciency Ratings Model EnerGuide Ratings Fireplace Ef ciency 2465 63 0 2466 63 0 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: