background image

33

Dutchwest Direct Vent / Natural Vent Gas Heater

30001935 

  Ref.  Description 

Dutchwest

Dutchwest Direct Vent / Natural Vent Gas Heater

Models 2465, 2466 (continued)

  10.  Glass, DV25 

1601691

  11.  Glass Frame Assembly - SDV30 

30000127

  12.  Gasket, Glass - Med. Knit - RDV40 

1203702 

  13a.  Valve RN Honeywell VS8420E 2038 (Serial #’s up to 6413)* 

10001782

  13b.  Valve RP Honeywell VS8420E 2020 (Serial #’s up to 6413)** 

10001759

  14.  Pilot Top Convertible 

10002266 

  15a.  Pilot Assembly 3Way N/DV RN 0.199.706 

10002264   

 

  Pilot Assembly 3Way N/DV RP 0.199.703 

10002265

  15b.  Pilot, PSE - NA175 

20001115 

 

 

  Pilot, PSE - LP175 

20001116

  16a.  Orifice Hood #69 - Front - LP 

30000513

  16b.  Orifice Hood #54 - Front - NG 

20000130

  16c.  Orifice Hood #54 - Rear - LP 

20000130

  16d.  Orifice Hood #44 - Rear - NG 

30000334

  17.  Thermocouple 24”  

53373 

 

 

   

7531137

  18.  Thermopile 18” RS  

51827 

 

 

   

7533113 

  19.  Electrode Ignitor w/Cable SIT24 

10001297

  20.  Nut Electrode SIT #0.974.144 

57886

  21.  Tubing Pilot w/Fittings 1/8 x 24” 

10001296

  22.  Burner Housing Assembly NG/LP 

20002214

  23.  Grate, Burner - JDV 

20002167 

  24.  Ashdoor Handle Assy - E/V/WSI 

5004241 

  25.  Handle, Damper - Maple Wood - Blk 

1600664

  26.  Switch ON/OFF - RN/RP Models 

30000874 

  27.  Wiring Harness - FSDV32 RN/JDV 

10002582

  28.  Right Log Bracket 

20005259

  29.  Left Log Bracket 

20005258 

  30.  Nut, Hex Jam 3/8 -16 TOPLK-Z 

1203290 

  31.  Gasket, Base Pan - JDV  

20002282

  32.  Gasket, Base Pan Inner  

20002566 

  33.  Furnace Cement 

1206150

  34.  Gasket, HE Door 

1203687

  35.  Sensor 2450 CMG-8184-0032 

10002013

  36.  Pan Hd, SL 1/4-20 x 3-Z 

1201310

  37a.  Valve Nova SIT820.662 RN (Serial #’s starting with 6414) 

20010563

  37b.  Valve Nova SIT820.653 RP (Serial #’s starting with 6414) 

20010645

  38.  Ignitor Piezo w/Nut SIT 

52464

  39.  Bracket Piezo Ignitor (not shown) 

20010876

Fuel Conversion Kits

Conversion Kit, NG to LP - 2465 

Kit #000-5022

Conversion Kit, LP to NG - 2466 

Kit #000-5021

*When converting to SIT valve, must order RP275
**When converting to SIT valve, must order RP269

Содержание Dutchwest 2465

Страница 1: ...ANUAL BEFORE INSTALLING AND USING APPLIANCE INSTALLER CONSUMER SAFETY INFORMATION FOR YOUR SAFETY Installation and service must be performed by a quali ed installer service agency or the gas supplier...

Страница 2: ...12 Install the Optional Fan 13 Venting System Assembly Direct Vent 14 Install Vent Adapter Pipe CFM Vent Components 14 Install Vent Adapter Pipe Simpson Dura Vent Components 15 Side Wall Termination A...

Страница 3: ...the room for combustion and vent the exhaust vertically through the roof to the atmo sphere This appliance is approved for bedroom installations in the U S and Canada This appliance may be installed...

Страница 4: ...utchwest stove is shipped from the factory as a Direct Vent Gas Heater This heater may be convert ed into a Natural Vent unit in the eld If a Natural Vent heater is desired the Z31D00 FSDHAG Draft Hoo...

Страница 5: ...her most often The vent system requirements NOTE We do not recommend the use of wallpaper next to this stove Over time radiant heat may cause the wallpaper to shrink or may adversely affect the binder...

Страница 6: ...ST131c Dutchwest wall thimble 5 15 03 djt A A Effective Minimum Wall Thimble 57 1461 mm CFM Pipe Centerline 53 1359 mm Simpson DuraVent Pipe ST131c Fig 5 Minimum wall thimble centerline Wall and Ceil...

Страница 7: ...ncial and or local authorities having jurisdiction for installations at elevations above 4 500 feet 1 370m WARNING Improper installation adjustment alteration service or maintenance can cause in jury...

Страница 8: ...ning the installation consider the location of the vent terminal and clearances Some of the most common clearances to keep in mind are shown in Fig ure 10 Important All vent clearances must be maintai...

Страница 9: ...als shall not be recessed into a wall or siding Horizontal venting must be installed on a level plane without an inclining or declining slope There must not be any obstruction such as bushes garden sh...

Страница 10: ...tor assy I Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air i...

Страница 11: ...ctor plate supplied with the stove is not used Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors G Combustible 6 15...

Страница 12: ...the Wall Vent Kit 7TFSMSK 1 90 Degree Elbow CG 1 24 Straight pipe CG 1 36 Straight pipe CG 1 Side Wall Termination 1 Firestop 1 Zero clearance sleeve 1 Hardware package 1 Finishing plate CG 1 Finishi...

Страница 13: ...onents 2 Remove the rear skirt insert panel at the bottom of the Rear Skirt Fig 13 and fasten the blower as sembly to the rebox back with the two Phillips pan head bolts originally installed in the re...

Страница 14: ...est restictor plate 5 15 03 ST759 Fig 16 Install the restrictor plate only if required for the vent ing con guration Refer to Page 8 2 Attach Inner Starter Pipe found in with the logset to the next se...

Страница 15: ...Simpson DuraVent install inner adapter pipe ST763 DW dura vent attach outer assy ST763 Fig 21 Simpson DuraVent install outer adapter pipe Side Wall Termination Assembly 1 Locate the vent opening on th...

Страница 16: ...equired if installing a second 90 elbow Fig 25 8 Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve Seal the joint inside the wall plate...

Страница 17: ...d Bracket Wall Screws and Anchors Waterproof Seal Around Pipe ST219 Fig 29 Use extension brackets to mount snorkel against recessed wall If the foundation is recessed use extension brackets not suppli...

Страница 18: ...types of B vent pipe use components from one maker or the other Follow the vent component maker s instructions exactly The heater will also accept standard or enam elled 7 150mm diameter pipe around...

Страница 19: ...the rebox 5 Loosely sprinkle the lava rocks directly on top of the burner in front of and between the decorative grate and the right and left logs Use the lava rock to cover brackets on the burner Fig...

Страница 20: ...inlet supply for adjustment of 5 5 w c In order to connect Propane use a tting with 3 8 NPT nipple on the valve side and 1 2 propane gas supply line with an input of 28 000 BTUs at a manifold pressure...

Страница 21: ...which holds the injectors at a 90 angle to the base Fig 40 This keeps the ori ces aligned with tubes on the inside of the burner Failure to do so could affect the ame appearance and performance of the...

Страница 22: ...e 3 8 locking nut provided Fig 43 The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body Position the front about 3 dow...

Страница 23: ...s sistance Do not operate the heater until the pilot ame is correct Follow regular maintenance procedures as described on Page 30 ST769 Dutchwest pilot location 5 15 03 djt Pilot Assembly ST769 Fig 45...

Страница 24: ...these instruc tions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF Y...

Страница 25: ...e thermocouple operates the pilot ame Tighten the thermocouple The thermopile operates the main valve ON and OFF Clean and or adjust pilot for maximum ame impingement on thermocouple and thermopile Tu...

Страница 26: ...on a at padded surface such as a coun ter protected by a towel 4 Remove the logset from the rebox 5 Remove the rear log bracket by unfastening the screw Fig 49 6 Remove the right and left log bracket...

Страница 27: ...spring and diaphragm assembly FC107 D E F FC108 SIT regulator conversion 10 03 OF F P I L O T O FC108 Fig 52 Replace regulator CO105a gas conversion Pilot 1 28 00 djt Pilot Hood Pilot Bracket CO105a...

Страница 28: ...he tubes inside burner Failure to do so could affect the ame appearance and performance of the unit 22 Place conversion label on valve 23 Reinstall the right and left log bracket assembly 24 Reinstall...

Страница 29: ...ature stove paints available through your local dealer to touch up areas as needed Clean areas to be painted with a wire brush and be sure to cover the logs burner and valve assembly glass and frame a...

Страница 30: ...g properly check the ames periodically to con rms they match Figure 61 The ames will be blue during the rst 15 20 minutes of operation and will gradually turn to yellow after that Do not use your stov...

Страница 31: ...t circuit NOTE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE SF 2 200 WIRE OR ITS EQUIVALENT Thermocouple Safety Limit Switch Valve ST665 Sa...

Страница 32: ...e changes in design materials speci cations prices and discontinue colors and products at any time without notice Dutchwest Direct Vent Natural Vent Gas Heater Models 2465 2466 Ref Description Dutchwe...

Страница 33: ...T24 10001297 20 Nut Electrode SIT 0 974 144 57886 21 Tubing Pilot w Fittings 1 8 x 24 10001296 22 Burner Housing Assembly NG LP 20002214 23 Grate Burner JDV 20002167 24 Ashdoor Handle Assy E V WSI 500...

Страница 34: ...itself does not require regular maintenance however periodic cleaning of the fan and the surround ing area is required Installation Refer to Page 13 for installation instructions Remote Controls The r...

Страница 35: ...vel fees or service charges for in home repair work It is the dealers op tion whether the repair work will be done in the customer s home or in the dealer s shop If upon inspection the damage is found...

Страница 36: ...Ef ciency Ratings Model EnerGuide Ratings Fireplace Ef ciency 2465 63 0 2466 63 0 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: