18
20306756
380IDV Fireplace Insert
INSERT INSTALLATION
ELECTRICAL WIRING
This insert will work without any electrical supply. Electricity
is only needed to operate blower.
REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga.
wire may be used with this appliance. Attach the wall switch
in a junction box at the desired location on the wall.
Figure
17
Verify proper operation after servicing.
NOTE:
Extended lengths of wire may cause the
fireplace not to function properly. Longer length of
wire is permitted if the wire is made out of larger gauge
(diameter) wire. Always check with local code.
PILOT
HI
LO
ON
OFF
FP1933
wall switch wiring
Figure 17 -
Wiring Diagram for Wall Switch
Sparker
Thermocouple
Piezo Igniter
Thermopile
Pilot Assembly
Switch
Millivolt
Valve
TH
TP
TH/TP
ON
OFF
Optional 15'
Wall Switch
Optional
Remote Control
ON
OFF
ON
OFF
W
ARNING
Electrical connections should only be per
-
formed by a qualified, licensed electrician.
Main power must be off when connecting to
main electrical power supply or performing
service. All wiring shall be in compliance
with all local, city and state codes. The ap
-
pliance, when installed, must be electrically
grounded in accordance with local codes,
or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (lat-
est edition)
and
Canadian Electrical Code,
CSA C22.1
.
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
CAUTION