20306756
380IDV Fireplace Insert
5
FP2621
IDV controls
PRE-INSTALLATION INFORMATION
PRODUCT SPECIFICATIONS
•
This appliance has been certified for use with either
natural or propane gas. Refer to the appropriate
data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsit-
ting room installations.
•
The appliance must be installed in accordance
with local codes if any. If none exist use the current
installation code. ANSI Z223.1/NFPA 54 in the USA,
CSA B149 in Canada.
•
The appliance must be properly connected to a
venting system.
Piezo Igniter
Figure 1 -
IDV Series Fireplace Insert
Optional
Remote
Receiver
Blower Knob
ON/OFF Switch
OFF/Pilot/ON
Knob
HI/LO Knob
Gas Shut-Off
Valve
On/Off
Remote
Switch
FP2621
W
ARNING
This appliance may be installed in an
aftermarket*, permanently located,
manufactured home, where not prohibited
by local codes
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
GAS PRESSURES
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
Max.Input Min. Input Orifice
Model
Fuel
BTU/h
BTU/h
Size
380IDVNV
Nat.
30,500
20,500
#35
380IDVPV
LP
22,000
18,000
#53
GAS SPECIFICATIONS & ORIFICE SIZE
The IDV Series gas inserts are equipped with a variable
speed output gas control.
NOTE:
IDV Series gas inserts operate without any elec-
trical supply. Blower must be attached to 110/120V AC.