4.  Never install the insert 

• 

in a recreational vehicle

  where curtains, furniture, clothing, or other flam

-

mable objects are less than 36" from the front, top, 

or sides of the insert

  in high traffic areas

  in windy or drafty areas 

5.  This insert reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or 

clothing ignition. Insert will remain hot for a time after 

shutdown. Allow surfaces to cool before touching. 

6.  Young children should be carefully supervised when 

they are in the same room as the appliance. Toddlers, 

young children and others may be susceptible to 

accidental contact burns. A physical barrier is recom-

mended if there are at risk individuals in the house. To 

restrict access to a fireplace or stove, install an adjust

-

able safety gate to keep toddlers, young children and 

other at risk individuals out of the room and away from 

hot surfaces.  

7.  Do not modify insert under any circumstances. Any 

parts removed for servicing must be replaced prior to 

operating insert. 

8.  Turn insert off and let cool before servicing, installing, 

or repairing. Only a qualified service person should 

install, service, or repair the insert. Have burner system 

inspected annually by a qualified service person. 

9.  You must keep control compartments, burners, and 

circulating air passages clean. More frequent cleaning 

may be needed due to excessive lint and dust. Turn off 

the gas valve and pilot light before cleaning insert. 

10. Have venting system inspected annually by a quali-

fied service person. If needed, have venting system 

cleaned or repaired. Refer to 

Cleaning and Mainte-

nance

, Page 29. 

11.  Keep the area around your insert clear of combustible 

materials, gasoline, and other flammable vapor and liq

-

uids. Do not run insert where these are used or stored. 

Do not place items such as clothing or decorations on 

or around insert. 

IMPORTANT SAFETY INFORMATION

This insert is a vented product. This insert must be properly 

installed by a qualified service person. The glass door must 

be properly seated and sealed. If this unit is not properly 

installed  by  a  qualified  service  person  with  glass  door 

properly seated and sealed, combustion leakage can occur. 

CARBON MONOXIDE POISONING:

 Early signs of carbon 

monoxide poisoning are similar to the flu with headaches, 

dizziness  and/or  nausea.  If  you  have  these  signs,  the 

insert may not have been installed properly. Get fresh air at 

once! Have the insert inspected and serviced by a qualified 

service person. Some people are more affected by carbon 

monoxide than others. These include pregnant women, 

people with heart or lung disease or anemia, those under 

the influence of alcohol, and those at high altitudes. 

Propane/LP gas and natural gas are both odorless. An 

odor-making agent is added to each of these gases. The 

odor helps you detect a gas leak. However, the odor added 

to these gases can fade. Gas may be present even though 

no odor exists.
Make certain you read and understand all warnings. Keep 

this manual for reference. It is your guide to safe and proper 

operation of this insert.
1.  This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases unless a certified 

kit is used. 

2.  For propane/LP insert, do not place propane/LP supply 

tank(s) inside any structure. Locate propane/LP supply 

tank(s) outdoors. To prevent performance problems, 

do not use propane/LP fuel tank of less than 100 

lbs. capacity. 

3.  If you smell gas

  shut off gas supply.

• 

do not try to light any appliance.

• 

do not touch any electrical switch; do not use any 

phone in your building .

• 

immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

WARNING

• 

Read this owner’s manual carefully and completely before trying to assemble, operate, or service this 

fireplace. 

• 

Any change to this fireplace or its controls can be dangerous.

• 

Improper installation or use of this fireplace can cause serious injury or death from fire, burns, explosions, 

electrical shock and carbon monoxide poisoning.

Содержание 380IDVNVSB

Страница 1: ...amage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Thisappliancemaybeinstalledinanaftermarket permanently located manu...

Страница 2: ...all On Off Switch 23 Installing Filigree Panels 23 Safety Barrier Installation 24 Operating Instructions 25 What To Do If You Smell Gas 25 Lighting Pilot for the First Time 25 Lighting Pilot 26 Lighti...

Страница 3: ...ified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakag...

Страница 4: ...2014 CSA 2 33 2014 STANDARDS A manufactured home USA only or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such...

Страница 5: ...ed home where not prohibited by local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certified wit...

Страница 6: ...533 mm C 21 533 mm D 21 533 mm E 16 406 mm Figure 3 IDV Fireplace Insert Opening Dimensions C A D B FP2530 hearth dims E 27 702 mm 17 443 mm 10 264 mm 4 114 mm 8 221 mm 15 395 mm 29 749 mm 30 767 mm 2...

Страница 7: ...ver obstruct the front opening of the insert Do not install in the vicinity where gasoline or other flammable liquids may be stored These units can be installed in a bedroom Refer to National Fuel Gas...

Страница 8: ...arth The hearth must also extend to both sides of the face Figure 4 Mantel Clearances FP2623 Minimum clearances Max 13 Max 3 4 Min 9 Min 11 13 330 mm Maximum Depth Minimum 8 203 mm 22 559 mm Minimum 1...

Страница 9: ...n a bedroom Please be aware of the large amount of heat this appliance pro duces when determining a location FP2624 insert placement Figure 5 Insert Placement For tight fits you may remove the manifol...

Страница 10: ...your room is well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during...

Страница 11: ...ing component Unauthorized modification of the venting system Installation of any component part not manufactured or approved by Vermont Castings Group Installation other than permitted by these instr...

Страница 12: ...ltitude contact your dealer Failure to adjust air shutter properly may lead to improper combustion which can create a safety hazard Consult your dealer or installer if you suspect an improperly adjust...

Страница 13: ...masonry or zero clearance fireplace FP2627 inlet exhaust reline Exhaust Inlet Recommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box...

Страница 14: ...ex Vent to Manifold 4 Attach flex vent to manifold Figure 11 Seal with silicone and attach with screws FP2631 pull excess vent Excess Flex Vent Chimney Slack in Flex Vent Manifold FP2632 Figure 12 Pul...

Страница 15: ...ator 9 08 External Regual tor Vent Pointing Down 100 gal min Propane LP Supply Tank FP1930 Figure 14 External Regulator with Vent Pointing Down Propane LP Only CAUTION Use only new black iron or steel...

Страница 16: ...c Pressure Propane LP From External Regulator 11 w c to 13 w c Pressure 3 Minimum FP1931 gas connection 9 08 Approved Flexible Gas Line Supplied with Appliance Tee Joint Pipe Nipple Cap Figure 15 Gas...

Страница 17: ...a soap and water solution or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to LO to get minimum pressure 5 To check gas pressures at v...

Страница 18: ...933 wall switch wiring Figure 17 Wiring Diagram for Wall Switch Sparker Thermocouple Piezo Igniter Thermopile Pilot Assembly Switch Millivolt Valve TH TP TH TP ON OFF Optional 15 Wall Switch Optional...

Страница 19: ...place 3 Set glass frame aside WARNING Make sure the glass panel edges do not touch any metal parts during thermal ex pansion CAUTION Always use gloves when handling broken glass DANGER HOT GLASS WILL...

Страница 20: ...pen front door of firebox 2 Break up rock wool ember material into dime sized pieces Place evenly as shown Do not exceed 1 layer Figure 18 3 Carefully remove the seven 7 logs from wrapping LG765 place...

Страница 21: ...f right base log Figure 23 LG771 place right center log 5 Right Center Log 5 Figure 23 INSERT INSTALLATION LG772 place right top log 6 Right Top Log 6 Figure 24 LG773 Place top Y log 7 Top Y Log 7 Fig...

Страница 22: ...four 4 hooks on back of surround with four 4 square notches on unit Figure 27 KT1334 attach eyebrow Surround Screws Eyebrow Figure 26 KT1334 KT1335 install surround Insert Hooks KT1335 Figure 27 3 Ins...

Страница 23: ...tch into hole in upper right side of the trim Figure 30 3 Reattach wires Figure 30 FP2635 rocker switch On Off Switch Tape wires to back of surround with foil tape Figure 30 Install On Off Switch NOTI...

Страница 24: ...d y toucher Ne laisser jamais les enfants toucher le panneau vitr A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed Une...

Страница 25: ...service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to ins...

Страница 26: ...ay lit repeat steps 1 and 2 LIGHTING PILOT Pilot Position Check for gas leaks in each of the following locations Pipe from the gas supply line connection to the gas valve Burner connections Field made...

Страница 27: ...ER Depress and turn the knob counterclockwise to the ON position It will take less than four 4 seconds for the burner to ignite PILOT POSITION Depress and turn knob to pilot position to keep burner of...

Страница 28: ...at sea level The burner on Natural Gas models may be adjusted for high altitude as follows To increase air mixture open the shutter more This will reduce soot formation Figure 32 To decrease air mixt...

Страница 29: ...ght film on the glass This is a temporary problem You should clean the glass after the first two weeks of use After that you should clean the glass no more than two or three times a season Use a mild...

Страница 30: ...efore cleaning Logs reach high temperatures Make sure clearances to combustibles leave enough room for maintenance and service Carefully reassemble and reseal insert properly after any cleaning or ser...

Страница 31: ...is found heater must be adjusted Contact dealer where you bought heater 4 Clean burner and burner ports Figure 37 5 Replace log set and rock wool per instructions on Pages 20 21 Replace glass Make sur...

Страница 32: ...it 1 Defective thermocouple Loose thermocouple 1 Check for proper connection of thermocouple to rear of valve 2 Air in gas line 2 Bleed line Contact dealer 3 No gas 3 Check shutoff valve and gas suppl...

Страница 33: ...6 blower wiring diagram Blower Snap Disc Variable Speed Control Hi Temp Hi Temp OFF ON 1 2 110 115 V AC Blower Plug Black White Green Blower Motor FP1946 NOTE Unplug power cord before servicing NOTE B...

Страница 34: ...34 20306756 380IDV Fireplace Insert REPLACEMENT PARTS 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 27 21 22 23 24 25 26 570016 IDV parts FIREBOX COMPONENTS...

Страница 35: ...1 57D0007 57D0007 18 Nipple 3 8 x 1 50 1 P1012 P1012 19 Disk Bracket 1 26D3320 26D3320 20 Rear Log 1 1 57D0170 57D0170 21 Left Log 2 1 57D0171 57D0171 22 Right Log 3 1 57D0172 57D0172 23 Left Center L...

Страница 36: ...comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ONLY 2 A...

Страница 37: ...Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage b...

Страница 38: ...38 20306756 380IDV Fireplace Insert This page intentionally left blank...

Страница 39: ...20306756 380IDV Fireplace Insert 39 This page intentionally left blank...

Страница 40: ...erchez dans la brochure les caract ristique de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com EFFICIENCY RATINGS...