Operating the Vacuum Excavator 50-17
Step 5:
At the operator console, if the Spoil Tank Full Light is ON, turn Tank Full
Override Switch
(3)
ON.
Step 6:
Turn Water Pump Switch
(4)
OFF.
Step 7:
Start engine and run at low idle. Close Upper Gate/Tank Inlet valve.
Step 8:
With the engine running at idle, and all inlet valves closed, vacuum will be
reached when the Vacuum Relief Valve
(5)
opens. The valve makes a
whistling sound when it opens.