STAGEMAKER®
-
39
VERLINDE reserves the right to alter or amend the above information without notice.
11/2008
maximum allowed for the throat opening( dimension 32.5 mm ) : 37mm
Please change your hook if the dimension is upper than 37 mm
10.7 Spare parts replacement table
Further to a long storage time or during annual service, check the function and the setting of the
safety devices (brake, end limit switch, slipping clutch…).If any component is deformed, or if abnormal
wear is noticed, the pieces must be changed.
,
Disconnect the power supply before replacing any parts.
Spare part
To be replaced by
Qualification of the personnel
Upper chain guide
Output shaft
PG cable gland
Gear input shaft + adjusting nuts
Motor endcap
Gearing (1st/2nd stage)
Brake cap/endcap sealing
Other sealings and O-rings
Brake-slipping clutch
Brake endcap
Lower chain guide
Rubber buffer
Electric box
PC-board
Plugs
Chain
Chain bucket
Slack fall stop
Suspension hook
Hook block (1/1; 2/1)
Control box
Authorized manufacturer personnel
Authorized manufacturer personnel
Authorized manufacturer personnel
Authorized manufacturer personnel
Authorized manufacturer personnel
Authorized manufacturer personnel
Customer
Authorized manufacturer personnel
Authorized manufacturer personnel
Customer
Customer
Customer
Authorized manufacturer personnel
Authorized manufacturer personnel
Customer
Customer
Customer
Customer
Customer
Customer
Customer
Qualified electrician
Qualified electrician
Qualified electrician
Qualified mechanic
Qualified mechanic
Qualified electrician
Qualified mechanic
Qualified mechanic
Qualified electrician
Qualified mechanic
Qualified mechanic
Qualified mechanic
Qualified electrician
Qualified electrician
Qualified electrician
Qualified mechanic
Qualified mechanic
Qualified mechanic
Qualified mechanic
Qualified mechanic
Qualified electrician
Once a part has been replaced, check the operation of the hoist
.
10.8 Screw tightening torques (Nm)
M5
M6
M8
M10
M12
Standard
screws
6 10 24 48 83
Self-tapping screws
5
8
20
40
72
10.9 Discarding the hoist
Once the hoist has been used for the FEM class duration, all of the components must be checked by
an authorized agent or by the manufacturer. The hoist should no longer be used,
unless agreement is
obtained from the authorized agent or the manufacturer
.
)
Remove all greases and oils from the hoist before discarding it.