HOW YOUR VERIPURE® SYSTEM WORKS  

 

YOUR PATENTED VERIPURE® SYSTEM HAS BEEN DESIGNED TO USE TWO STAGES OF PRIMARY FILTRATION 
AND LOW LEVEL OZONE TECHNOLOGY®. OPERATIONAL MAINTENANCE AND REPLACEMENT REQUIREMENTS 
ARE ESSENTIAL FOR THE VERIPURE® SYSTEM TO PERFORM TO SPECIFIATIONS. CONTACT YOUR LOCAL    
DEALER OR DISTRIBUTOR FOR REPLACEMENT FILTERS AND PARTS, OR CONTACT VERIPURE FOR THE DEALER 
NEAREST YOU. THE VERIPURE® SYSTEM IS RECCOMENDED TO BE CONNECTED TO MUNICIPAL WATER 
SOURCES. 

FOOD & SURFACES 

GENERAL RECOMENDATIONS FOR USING OZONATED WATER ARE AS FOLLOWS- 

 

PLACE ITEM OR ITEMS TO BE WASHED UNDER A STEADY STREAM OF VERIPURE® WATER AND RINSE. 

 

FOOD PREPARATION: IT IS RECOMMENDED ITEMS BE RINSED FOR 3 MINUTES WITH VERIPURE® WATER. 

 

FOOD ITEMS: PLACE IN A BOWL, COLANDER OR STRAINER. RINSE WITH VERIPURE® WATER. 

STORING WATER  

 

SELECT A CONTAINER THAT IS FOOD GRADE QUALITY, SUCH AS GLASS OR STAINLESS STEEL. THOROUGHLY RINSE 
THE CONTAINER WITH VERIPURE® WATER AT LEAST TWICE. FILL THE CONTAINER TO WITHIN ONE TO TWO INCHES 
FROM THE TOP AND REPLACE CAP. 

 

STORE WATER IN REFRIGERATOR AND MAKE CERTAIN THE CAP IS REPLACED AFTER EVERY USE. 

 

WHEN WATER IS FRESHLY OZONATED YOU MAY INITIALLY BE ABLE TO DETECT A SLIGHT HINT OF OZONE. PEOPLE 
VARY IN THEIR SENSITIVITY TO OZONE. ANY HINT OF THE OZONE TASTE WILL DISAPPEAR WITHIN A SHORT PERIOD 
OF TIME. YOUR SYSTEM PRODUCES MINIMAL WASTE WHILE PRESERVING MINERALS IN YOUR WATER. 

 

 

IMPORTANT NOTE:

  

VERIPURE® PERFORMANCE IS BASED UPON INPUT WATER WHICH MEETS MINIMUM 

EPA NATIONAL PRIMARY AND SECONDARY DRINKING WATER STANDARDS.                                                        
SEE 

WWW.EPA.GOV/DWSTANDARDSREGULATIONS 

Содержание VERIPUREVPC7000

Страница 1: ...1 OWNERS MANUAL VERIPUREVPC7000 REVISED 4 13 2020...

Страница 2: ...m THANK YOU FOR CHOOSING VERIPURE PLEASE TAKE A FEW MOMENTS TO FILL IN THE INFORMATION BELOW SAVE THIS MANUAL AS A CONVENIENT INFORMATION SOURCE FOR YOUR VERIPURE SYSTEM Date of Purchase Purchased Fro...

Страница 3: ...S TURN OFF THE WATER SUPPLY AT THE SINK OR WATER SOURCE AND UNPLUG POWER JACK FROM THE VERIPURE SYSTEM BEFORE PERFORMING ANY MAINTENANCE ACCESSORIES DO NOT USE ANY ACCESSORIES INCLUDING FILTER CARTRID...

Страница 4: ...OR 3 MINUTES WITH VERIPURE WATER FOOD ITEMS PLACE IN A BOWL COLANDER OR STRAINER RINSE WITH VERIPURE WATER STORING WATER SELECT A CONTAINER THAT IS FOOD GRADE QUALITY SUCH AS GLASS OR STAINLESS STEEL...

Страница 5: ...FORMANCE LIMIT YOUR VERIPURE SYSTEM TO 70 PSI OF WATER PRESSURE VERIPURE RECCOMENDS A MINIMUM WATER PRESSURE OF 50 PSI LOW WATER PRESSURE WILL CAUSE YOUR VERIPURE SYSTEM TO PRODUCE A LOWER QUANTITY OF...

Страница 6: ...BER AND OR ELECTRICIAN INSTALL YOUR VERIPURE SYSTEM IF YOU CHOOSE TO INSTALL THE UNIT YOURSELF AND ARE IN NEED OF ASSISTANCE PLEASE CALL 920 613 6771 FOR ASSISTANCE INSTALLATION OF THE VERIPURE SYSTEM...

Страница 7: ...SURIZED BEFORE REMOVING FITTINGS PUSH IN THE COLLET AGAINST THE FACE OF THE FITTING WITH THE COLLET HELD IN THIS POSITION THE TUBBING CAN BE REMOVED THE FITTING CAN THEN BE RE USED FLUSHING INSTRUCTIO...

Страница 8: ...rant application Special application Compact size 16 25 L x 6 W x 18 25 H 41 275cm L x 15 24cm W x 46 35cm H Light weight 9 0 lbs 19 8 kg No water wasted Low Voltage DC operation with 115 VAC UL wall...

Страница 9: ...is malfunctioning LED READOUT INSTALLED VERIPURE There are two maintenance requirements for your VeriPure System 1 Change the filter cartridge assembly when indicated by the LED readout on your VeriPu...

Страница 10: ...ss water and remove and discard of used filters 4 Wipe out any debris or build up inside of canister TO INSTALL NEW FILTERS 1 Open new carbon sediment filters from wrapping packaging 2 Place filter in...

Страница 11: ...ve the Dielectric tube from the VeriPure housing by sliding the Dielectric out IN A STRAIGHT LINE until the Dielectric tube is completely separated from the VeriPure housing 5 The old Dielectric tube...

Страница 12: ...AND FIRMLY SEATED WITH NO EVIDENCE OF WATER LEAKAGE TROUBLE SHOOTING GUIDE At VeriPure Inc we expect your VeriPure System to function properly for years as long as you perform the maintenance accordi...

Страница 13: ...URE WILL NOT ALLOW YOUR SYSTEM OZONATION COMPONENTS TO TURN ON REGAIN INCOMING WATER PRESSURE TO MINIMUM OF 50 PSI CONTACT YOUR PLUMBER OR MUNICIPALITY DROP IN OR NO WATER FLOW PLUGGED FILTER CHANGE Y...

Страница 14: ...OES THE OZONE AFFECT THE TASTE OF THE WATER Initially there is a slight aroma of ozone This dissipates after a short period of time approximately 20 seconds IS THE OZONE GAS RELEASED INTO THE AIR BY V...

Страница 15: ...aler in a timely manner following discovery of the claimed defect Any claim under this warranty must be made within 30 days following the expiration of the one year warranty VeriPure LLC reserves the...