Nextiva S2800e Series User Guide
Verint Video Intelligence Solutions
25
To connect the power wires to the interface board:
1. Strip approximately 1 inch (25 mm) of the outer jacket of the power cable that will go
in the terminal block.
2. Strip approximately 0.25 inches (6 mm) of insulation off each individual wire on the
power cable.
3. Insert each power wire into the 2-pin terminal block using the following wiring
information (both wires are used for power):
4. Tighten the screws on the terminal block.
5. Install the terminal block on the interface board at the TB1 location.
6. Connect the other end of the power cable into a 24V AC power supply.
Connecting Alarms and Relays
The S2800e includes the following alarm and relay signals:
Local alarm signals available on the TB2 connector, on the main interface board
Local relay signal available on the TB4 connector, on the main interface board
Nextiva alarm and relay signals on the Verint mezzanine board
These signals are programmable to fit your alarm needs.
Pin Number
Pin Label
Signal
TB1/1
H
Hot
TB1/2
N
Neutral
Local alarms on connector TB2
Local relay on connector TB4
Nextiva alarm and relay
Nextiva S2800e Series User Guide.book Page 25 Wednesday, March 11, 2009 3:20 PM