Verine VLF45NG Скачать руководство пользователя страница 8

FIGURE 5 

 

7   

IR Signal Receiver 

 

The  signal  receiver  should  be  placed  on  the  hearth  just  behind  the  ash  pan  cover 
such  that  it  is  visible  to  the  user  operating  the  remote  control  handset.   

If  the 

receiver is covered in any way the fire will not operate. 

 The receiver is secured 

to  a  bracket  with  a  screw  which  can  be  removed  when  the  burner  is  taken  out  for 
service.    The  bracket  should  be  fixed  to  the  hearth  with  the  double  sided  tape 
provided 

after

  having  selected  a  suitable  position  for  it  with  the  fret  and  ash  pan 

cover  in  position  (See  Figure  5).    The  signal  receiver  must  be  positioned  on  the 
bracket with the raised part facing the user. 

Fitting the Battery to the Handset 

 

Before  using  the 
appliance 

remove 

the  access  cover  in 
the  rear  of  the 
handset  and  insert 
a  9-volt  PP3  size 
battery.    Connect 
the 

battery 

by 

pushing 

the 

connector  on  to  the 
terminals.    Make 
sure  the  battery  is 
connected correctly.  
Replace the access cover. 

ASSEMBLING THE FIRE AND PLACING THE LOGS 

WARNING

 

This  product  uses  fuel  effect  pieces  containing  Refractory  Ceramic  Fibre 
(RCF),  which  are  man-made  vitreous  silicate  fibres  along  with  fibrous  glass 
and mineral wool. Excessive exposure to these materials may cause temporary 
irritation  to  eyes,  skin  and  respiratory  tract;  consequently,  it  makes  sense  to 
take  care  when  handling  these  articles  to  ensure  that  the  release  of  dust  is 
kept to a minimum.  

FIGURE 6 

Содержание VLF45NG

Страница 1: ...odels THIS IS NOT A DO IT YOURSELF PRODUCT THIS APPLIANCE MUST BE INSTALLED BY A CORGI REGISTERED PERSON INSTALLATION USERS AND SERVICING INSTRUCTIONS THESE PRODUCTS ARE APPROVED TO THE EUROPEAN GAS D...

Страница 2: ...the User 10 USERS GUIDE 11 Useful tips recommendations 11 Operation of your appliance 11 Manual Appliances 12 Remote Appliances 13 Cleaning your fire 14 SERVICING MAINTENANCE 15 Spares Parts list 16 G...

Страница 3: ...or Setting Low mbar 5 5 7 0 Gas Connection 8mm Compression Fuse Rating Amps N A 3 N A 3 Weight Kg 3 5 4 5 3 5 4 5 Dimensions of burner 450mm wide 250mm deep 190mm high GENERAL INSTALLATION REQUIREMENT...

Страница 4: ...d the height should be matched to the cross section of the fireplace opening See BS 5871 Part 3 5 The flue must have a minimum effective height of 3 metres 6 No restrictor plate or flue damper is perm...

Страница 5: ...Part 2 requires a debris collection space of 12 dm3 2 It is recommended that before proceeding further a simple smoke test be performed to check the condition of the chimney Light a smoke match or a...

Страница 6: ...the nut and olive provided connect the 8mm supply pipe to the combined pressure test point and isolator fitting 13 Complete the installation of the appliance as above ADDITIONAL NOTES FOR HANDSET REMO...

Страница 7: ...light the control box under the fire should emit a series of beeps if an attempt is made to light the fire when the batteries do not have sufficient charge or on a regular basis as convenient to the u...

Страница 8: ...the bracket with the raised part facing the user 8 Fitting the Battery to the Handset Before using the appliance remove the access cover in the rear of the handset and insert a 9 volt PP3 size batter...

Страница 9: ...the front ceramic Place the side ceramics either side of the base ceramic 2 With reference to figure 7 on the following page lay the logs as follows a Place the largest log in its moulded seat at the...

Страница 10: ...ning the appliance 3 Light a smoke match and pass completely along the front edge and just inside the top edge of the fireplace or firebox A visual check should ascertain that all the smoke generated...

Страница 11: ...that the terms and conditions of your warranty see page 17 are met this must be undertaken annually and the Service Engineer must complete the Service Record Page 18 10 These instructions are provided...

Страница 12: ...he pilot position and keep it depressed 3 Lighting the pilot burner is done by turning the control knob still depressed from the OFF position to the PILOT position when the spark generator will be hea...

Страница 13: ...set at high and a flame height between high and low fire is desired press and continue to hold the low fire button after the beep has sounded The flame height will gradually decrease Release the butto...

Страница 14: ...f the batteries and all connections Charge the batteries overnight or as indicated by the instructions that were included with the new batteries CLEANING YOUR FIRE 1 Ensure that the fire is cold befor...

Страница 15: ...he primary safety device on the appliance It must therefore be replaced annually After changing the pilot burner operate the spark generator and observe that the spark is satisfactory 5 Lay the burner...

Страница 16: ...LVE L P G MANUAL INC PIEZO HT LEAD P12 SPECIAL ORDER GAS CONTROL BM VALVE NATURAL GAS L P G S C INC PIEZO HT LEAD P12 SPECIAL ORDER SIT TANDEM 830 SOLENOID VALVE NATURAL GAS L P G S C ONLY P97 22NG EX...

Страница 17: ...very purchase is returned to us for registration within four weeks of the date of purchase with the details correctly filled in e That any part or parts on which a claim is made are returned to us pos...

Страница 18: ...d SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4 th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5 th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 19: ...19...

Страница 20: ...0 Verine Limited 52 Broton Drive Trading Estate Halstead Essex CO9 1HB Tel 01787 472551 Fax 01787 476589 Email sales verine co uk Website www verine co uk LOG 1006 II UI THIS BOOKLET CONTAINS 20 PAGES...