3
Before fitting this appliance, ensure that the following list of components are
enclosed
(a) Vesta Burner unit
(b) 1 Set Ceramic Base Pieces (1 Base, 1 LH Side, 1 RH Side, 1 Front, 1 Burner.)
(c) 1 Log Set (4 Pieces)
(d) Installation, User & Servicing Instructions
(e) For Handset Remote Models only 1 Handset Control unit c/w 9V alkaline battery
1 Signal receiver (with mount)
1 Battery Charger c/w lead & jack plug
1 Rechargeable Battery pack & wiring harness
A
PPLIANCE DATA
VLF45NG
(Manual)
VLF45NG
(Remote)
VLF45P
(Manual)
VLF45P
(Remote)
Gas Type
Natural Gas
Propane
Heat Input
(Gross) (kW)
11.0
10.3
Supply Pressure
(mbar)
20
37
Injector Size
(mm)
2.75
1.6
Injector Setting
(High) (mbar)
14.5
28.0
Injector Setting
(Low) (mbar)
5.5
7.0
Gas Connection
8mm Compression
Fuse Rating
(Amps)
N/A
3
N/A
3
Weight (Kg)
3.5
4.5
3.5
4.5
Dimensions of burner: 450mm wide, 250mm deep, 190mm high.
G
ENERAL
I
NSTALLATION
R
EQUIREMENTS
1
The law demands that all gas appliances are installed by a qualified installer in
accordance with the current
Gas Safety (Installation and Use) Regulations.
The
installation must comply with these installation instructions and all relevant parts of
Local and National Building Regulations or Building Standards (Scotland)
(Consolidation) Regulations and those relevant recommendations of the following
British Standards.
BS 5871: Part 2
BS 8303
BS 5440: Parts 1 and 2
BS 1251
BS 6891
The current IEE wiring regulations, Local Building Regulations and the Building
Standards (Scotland) (Remote Models only).
These Installation Instructions must be adhered to without exception.
Содержание VLF45NG
Страница 19: ...19...