Verine VLF45NG Скачать руководство пользователя страница 13

13 

Remote Appliances 

Using the handset

 

When using the handset make sure that it is 

pointed  at  the  infra  red  signal  receiver 
located under the front  of the fire (the small 
black pad).  Unlike a TV control the fire does 
not  react  to  a  quick  press  on  the  button  on 
the  handset  control.    The  buttons  must  be 
pressed and held until the control box under 
the fire acknowledges the signal by emitting 
a  'beep'  sound  (this  can  take  two  or  three 
seconds)  and  then  released.    When  the 
handset  is  emitting  a  signal  the  yellow  LED 
at the top of the control will flash.  

10 

Lighting the Fire 

See Figure 9 

To  light  the  fire  press  the  OFF  and  the 

STAND BY buttons together on the handset 
until  the  fire  control  box  answers  with  a 
'beep'  and  then  released.  The  fire  will  go 
through  its  start  -  up  procedure  by  lighting 
first  the  pilot  burner  and  then  the  main 
burner  on  high  fire.  This  procedure  takes 
about 30 seconds. If the fire does not light or 
there is no reaction when the two buttons are pressed, press the OFF button  to re-
set the control and try again. 

11   

Adjusting the Flame Height

 

 

 

To turn the fire from high to low, press and release the low fire button as soon as the 
'beep' is heard and the flame height will reduce. If the fire is set at high and a flame 
height  between high and low fire is desired, press and continue to hold  the low fire 
button  after  the  'beep'  has  sounded.  The  flame  height  will  gradually  decrease. 
Release  the  button  when  the  desired  height  of  flame  is  achieved.  To  turn  the  fire 
from low fire to high fire press and (after the 'beep' is sounded) release the high fire 
button.  To  gradually  increase  the  flame  press  and  hold  the  button  as  described 
above for the low fire button. 

12 

Turning the Fire OFF 

To turn the fire off but leave the pilot burner alight press the STAND-BY button until 

the 'beep' is heard.  Use  this facility to conserve battery life if the fire is going to be 
used again later in the day. To turn the fire completely off press the OFF button. The 
STAND-BY  button  and  the  OFF  button  can  be  pressed  when  the  flame  is  at  any 
height. To light the main burner from the STAND-BY position press either the HIGH 
FIRE or LOW FIRE buttons. 

13 

Manual OFF Facility 

If,  whilst  the  fire  is  alight,  the  handset  control  is  lost  or  its  battery  becomes 

discharged the fire can be turned off by pressing and holding the manual off button 
situated on the fascia underneath the front of the burner. This button disconnects the 
battery from the control box and the fire will go out after the button has been held in 
for  about  a  minute.    Care  should  be  taken  as  the  fret  /  ash  pan  cover  as  well  the 
burner facia will be hot. 

Figure 11 

 

 

FIGURE 9 

Содержание VLF45NG

Страница 1: ...odels THIS IS NOT A DO IT YOURSELF PRODUCT THIS APPLIANCE MUST BE INSTALLED BY A CORGI REGISTERED PERSON INSTALLATION USERS AND SERVICING INSTRUCTIONS THESE PRODUCTS ARE APPROVED TO THE EUROPEAN GAS D...

Страница 2: ...the User 10 USERS GUIDE 11 Useful tips recommendations 11 Operation of your appliance 11 Manual Appliances 12 Remote Appliances 13 Cleaning your fire 14 SERVICING MAINTENANCE 15 Spares Parts list 16 G...

Страница 3: ...or Setting Low mbar 5 5 7 0 Gas Connection 8mm Compression Fuse Rating Amps N A 3 N A 3 Weight Kg 3 5 4 5 3 5 4 5 Dimensions of burner 450mm wide 250mm deep 190mm high GENERAL INSTALLATION REQUIREMENT...

Страница 4: ...d the height should be matched to the cross section of the fireplace opening See BS 5871 Part 3 5 The flue must have a minimum effective height of 3 metres 6 No restrictor plate or flue damper is perm...

Страница 5: ...Part 2 requires a debris collection space of 12 dm3 2 It is recommended that before proceeding further a simple smoke test be performed to check the condition of the chimney Light a smoke match or a...

Страница 6: ...the nut and olive provided connect the 8mm supply pipe to the combined pressure test point and isolator fitting 13 Complete the installation of the appliance as above ADDITIONAL NOTES FOR HANDSET REMO...

Страница 7: ...light the control box under the fire should emit a series of beeps if an attempt is made to light the fire when the batteries do not have sufficient charge or on a regular basis as convenient to the u...

Страница 8: ...the bracket with the raised part facing the user 8 Fitting the Battery to the Handset Before using the appliance remove the access cover in the rear of the handset and insert a 9 volt PP3 size batter...

Страница 9: ...the front ceramic Place the side ceramics either side of the base ceramic 2 With reference to figure 7 on the following page lay the logs as follows a Place the largest log in its moulded seat at the...

Страница 10: ...ning the appliance 3 Light a smoke match and pass completely along the front edge and just inside the top edge of the fireplace or firebox A visual check should ascertain that all the smoke generated...

Страница 11: ...that the terms and conditions of your warranty see page 17 are met this must be undertaken annually and the Service Engineer must complete the Service Record Page 18 10 These instructions are provided...

Страница 12: ...he pilot position and keep it depressed 3 Lighting the pilot burner is done by turning the control knob still depressed from the OFF position to the PILOT position when the spark generator will be hea...

Страница 13: ...set at high and a flame height between high and low fire is desired press and continue to hold the low fire button after the beep has sounded The flame height will gradually decrease Release the butto...

Страница 14: ...f the batteries and all connections Charge the batteries overnight or as indicated by the instructions that were included with the new batteries CLEANING YOUR FIRE 1 Ensure that the fire is cold befor...

Страница 15: ...he primary safety device on the appliance It must therefore be replaced annually After changing the pilot burner operate the spark generator and observe that the spark is satisfactory 5 Lay the burner...

Страница 16: ...LVE L P G MANUAL INC PIEZO HT LEAD P12 SPECIAL ORDER GAS CONTROL BM VALVE NATURAL GAS L P G S C INC PIEZO HT LEAD P12 SPECIAL ORDER SIT TANDEM 830 SOLENOID VALVE NATURAL GAS L P G S C ONLY P97 22NG EX...

Страница 17: ...very purchase is returned to us for registration within four weeks of the date of purchase with the details correctly filled in e That any part or parts on which a claim is made are returned to us pos...

Страница 18: ...d SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4 th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5 th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 19: ...19...

Страница 20: ...0 Verine Limited 52 Broton Drive Trading Estate Halstead Essex CO9 1HB Tel 01787 472551 Fax 01787 476589 Email sales verine co uk Website www verine co uk LOG 1006 II UI THIS BOOKLET CONTAINS 20 PAGES...

Отзывы: