3-8
W A N s u i t e 5 1 6 5
The four columns of the status table are as follows:
The table provides error status and alarm threshold information for the
following error parameters:
ES
Sets the Errored Seconds (ES) threshold. An ES is a 1-second period in which
at least one logic error occurred. The default value is 45 seconds.
SES
Sets the Severely Errored Seconds (SES) threshold. An SES is a 1-second
period in which at least 320 CRC errors or one Out -of-Frame (OOF) error
occurred. The default value is 5 seconds.
LOSS
Sets the Loss of Signal Seconds (LOSS) threshold. A LOSS is a 1-second
period in which the T1 received signal is interrupted. The default value is 5
seconds.
UAS
Sets the Unavailable Seconds (UAS) threshold. A UAS is a 1-second period
in which consecutive severely errored seconds cause an unavailable state. The
default is 0 (zero) seconds (Disabled).
CSS
Sets the Controlled Slip Seconds (CSS) threshold. The default is 0 (zero)
seconds (Disabled).
BPVS
Sets the Bipolar Violation Errored Seconds (BPVS) threshold. A BPVS is a 1-
second period in which at least one bipolar violation occurred. The default is
0 (zero) seconds (Disabled).
OOFS
Sets the Out of Frame Seconds (OOFS) threshold. An OOFS is a 1-second
period in which a frame sync loss occurred. The default value is 5 seconds.
AISS
Sets the Alarm Indication Signal Seconds (AISS) threshold. An AIS is a 1-
second period when unframed all ones are received. The default is 0 (zero)
seconds (Disabled).
RAS
Sets the Remote Alarm Seconds (RAS) threshold. A RAS is generated by the
terminal equipment when an improper signal is received from the facility (or
upon receipt of unframed all ones). The default is 0 (zero) seconds (Disabled).
Reset Timer
Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
•
Status
Displays the current status of the network port.
•
Alarm
Displays the alarm value of the network port. The unit
declares an alarm as soon as the count exceeds the threshold
set.
•
Count
Displays the number of events or occurrences of this statistic
that have been detected.
•
Threshold
A read/write field that can be set to a desirable threshold.
Содержание WANsuite 5165
Страница 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...
Страница 4: ...iv W A N s u i t e 5 1 6 5...
Страница 10: ...x W A N s u i t e 5 1 6 5...
Страница 26: ...1 12 W A N s u i t e 5 1 6 5...
Страница 30: ...2 4 W A N s u i t e 5 1 6 5...
Страница 124: ...3 94 W A N s u i t e 5 1 6 5...
Страница 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...
Страница 224: ...A 10 W A N s u i t e 5 1 6 5...