Hello Timer
Specifies the BPDU broadcasting interval.
Values: 1
−
65535 s
Default: 10 s
Max Age Timer
Specifies the length of time a bridge will consider the network topology held
in memory as valid.
Values: 1
−
65535 s
Default: 60 s
Forward Delay
Specifies the length of time to delay creation of a temporary loop in the
network.
Values: 1
−
65535 s
Default: 5 s
Filter Ageing Timer
Specifies the length of time an entry in the lookup table will be held if no
traffic is received from the specified MAC Address.
Values: 1
−
65535 s
Default: 300 s
The Bridge Details screen provides the following user-activated buttons:
Figure 3.87
Bridge Port Table
The Bridge Port Table screen lets you view the parameters described below
the Bridge Port Details screen. Clicking on a number in the “Index” column
of the Bridge Port Table will bring up the Bridge Port Details screen, which
displays, and, in some cases, lets you change, the parameters described below.
Button
Function
Submit
Sets any values that have been changed.
Bridge Port Table
Displays the Bridge Port Table screen (Figure 3.87) that lets
the user access and configure the Bridge Port Details screen
(Figure 3.88).
Bridge Lookup Table
Displays the Bridge Lookup Table screen (Figure 3.89) that
contains all MAC Addresses learned by the Bridge.
Содержание WANsuite 5165
Страница 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...
Страница 4: ...iv W A N s u i t e 5 1 6 5...
Страница 10: ...x W A N s u i t e 5 1 6 5...
Страница 26: ...1 12 W A N s u i t e 5 1 6 5...
Страница 30: ...2 4 W A N s u i t e 5 1 6 5...
Страница 124: ...3 94 W A N s u i t e 5 1 6 5...
Страница 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...
Страница 224: ...A 10 W A N s u i t e 5 1 6 5...