![Verilink WANsuite 5165 Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/verilink/wansuite-5165/wansuite-5165_reference-manual_1004291170.webp)
4-46
W A N s u i t e 5 1 6 5
Remote Unit
If the remote unit is a Verilink unit with FrameStart technology, and
FrameStart Auto Discovery is enabled, this field displays the first three digits
of the unit ID configured on the remote end of this DLCI.
Values: 000
−
999
Default: 000
Remote IP Address
Displays the IP address of the remote Verilink unit with FrameStart
technology if FrameStart Auto Discovery is enabled.
Round Trip Delay
Specifies the frame size (in bytes) of packets making round-trip.
Round Trip Rate
Specifies the rate (in seconds) at which Round Trip Delay packets are sent.
DLCI Status Table
The bottom portion of the screen shows a table detailing the actual status of this
DLCI and alarm threshold information as follows:
Status
If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”
Values: Active, Inactive
Default: Inactive
Receiving FECN/
BECN
When a frame is received with congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without congestion bit
set.
Values: Yes, No
Default: No
CIR Threshold
Sets the Tx over CIR alarm threshold. This threshold is the number of bits per
second in excess of CIR during a 15-minute interval. Setting this field to “0”
(zero) disables the alarm.
CIR Alarm
Reports if the Tx over CIR threshold has been exceeded.
Bits Over Be Threshold
Sets the Tx over excess burst alarm threshold. This threshold is the number of
bits per second in excess of CIR + Be during a 15-minute interval. Setting
this field to “0” (zero) disables the alarm.
Bits Over Be Alarm
Reports if the Tx over Be threshold has been exceeded.
Congestion Threshold
Sets the Rx Congestion alarm threshold. This threshold is the number of
frames received with BECN/FECN. Setting this field to “0” (zero) disables
the alarm.
Congestion Alarm
Reports if the Rx Congestion threshold has been exceeded.
BECN in CIR
Reports if Backward Explicit Congestion Notification (BECN) has been
received within CIR.
Содержание WANsuite 5165
Страница 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...
Страница 4: ...iv W A N s u i t e 5 1 6 5...
Страница 10: ...x W A N s u i t e 5 1 6 5...
Страница 26: ...1 12 W A N s u i t e 5 1 6 5...
Страница 30: ...2 4 W A N s u i t e 5 1 6 5...
Страница 124: ...3 94 W A N s u i t e 5 1 6 5...
Страница 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...
Страница 224: ...A 10 W A N s u i t e 5 1 6 5...