Verilink WANsuite 5165 Скачать руководство пользователя страница 151

V T 1 0 0   I n t e r f a c e

4-27

Frame Relay Service Details Screen

Access the Frame Relay Service Details screen (Figure 4.24) by selecting 
“Frame Relay” under the <Type> column on the Service Table screen.

Figure 4.24

Frame Relay Service Details Screen 

The Frame Relay Service Details screen displays Service, Pair, and Interface 
details across the top of the screen. Fields shown at the top of the Frame 
Relay Service Details screen are listed below. 

Screen parameters that can be viewed and/or changed are listed below. To 
save new parameters, press the “Esc” key.

Interface Type

If this service is connected to a Frame Relay network, the Interface Type 
should be set to “UNI” as it is the user side of a User-to-Network interface. If 
it is connected to a FRAD/router, the Interface Type should be set to “NI” as 
it is the network side of a User-to-Network interface. If it is connected to an 
equipment set for Network-to-Network interface, the Interface Type should be 
set to “NNI.”

Values: UNI, NI, NNI
Default: UNI if interface is Network, NI if interface is Serial

Link Management

This parameter should be set to the link management used by the equipment 
connected to it. If set to “Auto,” the unit will learn the link management type 
and display it on the status portion of this screen.

Field

Description

Active

Read-only status (No, Yes)

LMI Type

Read-only status 

FrameStart Status

Read-only status 

Round Trip Delay (bytes)

Specifies the frame size (in bytes) of packets making 
round-trip.

Round Trip Rate (sec)

Specifies the rate (in seconds) at which round-trip 
packets are sent.

Содержание WANsuite 5165

Страница 1: ...i WANsuite 5165 Reference Manual October 2002 34 00301 H...

Страница 2: ...reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed...

Страница 3: ...tions du Canada Safety Precautions When handling this equipment follow these basic safety precautions to reduce the risk of elec tric shock and injury Follow all warnings and instructions marked on th...

Страница 4: ...iv W A N s u i t e 5 1 6 5...

Страница 5: ...of the WANsuite 5165 1 3 Performance 1 3 SNMP Management 1 3 Intelligent WAN Access Architecture 1 3 Optional Advanced Network Management 1 4 About FrameStart Technology 1 4 WANsuite 5165 Overview and...

Страница 6: ...1 Interface Details Button 3 22 Type Details Button 3 22 Delete Service Button 3 22 DS0 Monitor Details Screen 3 22 DS0 Status and Alarm Table 3 23 Frame Relay Service Details Screen 3 25 Status and A...

Страница 7: ...Upload Save 3 90 Password 3 91 Log Out 3 92 In band Management 3 92 Use of Connected Local Router 3 92 Use of Local WANsuite 5165 as a Gateway 3 93 Chapter 4 VT100 Interface Introduction 4 1 Accessing...

Страница 8: ...er Statistics Screen 4 51 SNMP Details Screen 4 52 Diagnostics Screen 4 53 Test Details Screens 4 53 Trap Log Screen 4 57 Top Talkers Screen 4 57 IP Gateway Screen 4 58 RIP Parameters 4 59 OSPF Parame...

Страница 9: ...ctor Pin Assignments A 7 Serial Interface Pin Assignments for DTE Mode Packet Use Only A 7 Serial Interface Pin Assignments for DCE Mode A 8 Ethernet Connection Pin Assignments A 8 Network 1 Interface...

Страница 10: ...x W A N s u i t e 5 1 6 5...

Страница 11: ...ters to understand the subsequent chapters Appendices are designed to complement the main chapters Chapter 1 About the WANsuite 5165 This chapter describes product features and capabilities Chapter 2...

Страница 12: ...to provide a variety of services including network planning installation hardware maintenance application training and support services When you contact your network supplier for assistance have the...

Страница 13: ...eference manual is revised to reflect code changes or other updates the most recent version will be posted to the Verilink Web site Returning a Unit to Verilink If for any reason you must return your...

Страница 14: ...o use when returning a unit to Verilink will be provided when the RMA is issued The standard delivery method for return shipments is Standard Ground for domestic returns and International Economy for...

Страница 15: ...synchronous Supervisory port a 10 100Base T Ethernet interface and five status LEDs Capable of accommodating a wide range of network configurations the WANsuite 5165 effectively combines voice data an...

Страница 16: ...transit across your network Because IP Gateway enables WANsuite to route IP traffic either statically or dynamically across your LAN WAN architecture your need for costly routers is substantially red...

Страница 17: ...management enterprise managers can now manage Verilink WANsuite units and their integral CSU DSUs as a single unit With only one LAN segment in the network all Verilink WANsuite platforms can be manag...

Страница 18: ...relay service is operational prior to installation and connection to other equipment FrameStart s integral frame relay circuit installation and diagnostic tools help reduce equipment and installation...

Страница 19: ...e the following Offers two Network ports two Serial ports an asynchronous Supervisory port and an Ethernet port the WANsuite 5165 is extremely flexible and adapts to numerous network applications Ensu...

Страница 20: ...ultiple connections to TCP clients Asynchronous multicasting lets the WANsuite 5165 transmit identical data to multiple endpoints SCADA traffic priority puts SCADA traffic in a specific queue over a f...

Страница 21: ...TELNET Local Supervisory port Ethernet port for management or IP routing Frame Relay Aware Support for leased line and frame relay services Layer 2 end to end visibility and control Embedded frame re...

Страница 22: ...in DTE Mode The indicator is off not illuminated when the port has not been configured The indicator lights red when DSR is not active and the configured protocol is not established The indicator lig...

Страница 23: ...nfigure the unit to disable their transmission NOTICE A null modem crossover cable is required to connect a modem to the Supervisory port Data Interface Module Rear Panel The Data Interface Module DIM...

Страница 24: ...that interconnecting cables carrying high speed data be shielded appropriately in order to minimize radio frequency interference Network Interfaces Labeled on the rear panel of the WANsuite 5165 as NE...

Страница 25: ...for approximately 10 to15 seconds as the unit initializes The green POWER LED will remain illuminated as long as the unit receives power This LED turns amber when the unit is in test mode Power Failu...

Страница 26: ...1 12 W A N s u i t e 5 1 6 5...

Страница 27: ...ed from the rear of the shelf into the backplane The WANsuite 5165 front module is installed from the front The DIM is always installed first and removed last the WANsuite 5165 front module is install...

Страница 28: ...t the unit must first be configured with an IP address You can configure the unit s IP address using the Verilink Configuration Wizard which is included on your documentation CD NOTICE You may also ac...

Страница 29: ...the Tab key again move the cursor to the IP Address field and enter the appropriate IP address for the unit xxx xxx xxx xxx If necessary repeat this process for the Subnet Mask and Gateway Address fie...

Страница 30: ...2 4 W A N s u i t e 5 1 6 5...

Страница 31: ...n the navigation bar on the left side of the Web Server interface screen However because the parameters you specify in the Service Table attach protocols to interfaces you must configure the Service T...

Страница 32: ...e area beneath the upper frame is divided into two side by side frames The frame on the left side of this area depicts a hierarchical tree structure used to navigate through the various interface scre...

Страница 33: ...lds the unit s location FrameStart ID Read write field that holds the unit s ID that uniquely identifies the unit and is used in the FrameStart applications User Definable Fields Read write fields for...

Страница 34: ...will be set back to the specified factory default Figure 3 2 Maintenance Reset Screen Save and Restart Use this button to save the current configuration settings and proceed with the restart as shown...

Страница 35: ...u view and make changes to the Network interfaces configuration as described below In addition the screens provide a table that displays the alarm values for the Network interfaces All Network ports o...

Страница 36: ...ul Specifies the DTE DSX 1 interface output level Values 0 110 111 220 221 330 331 440 441 550 551 660 661 ft Default 0 110 ft Framing Selects the framing for the network side of the DSU CSU Values ES...

Страница 37: ...overed DS0 will be set Values As 56K 64K Default As 64K NOTICE The unit will search for active DS0s for a maximum of 7 seconds if learning As 64k and for 30 seconds if learning As 56K Error Status and...

Страница 38: ...ored Seconds BPVS threshold A BPVS is a 1 second period in which at least one bipolar violation occurred The default is 0 zero seconds Disabled OOFS Sets the Out of Frame Seconds OOFS threshold An OOF...

Страница 39: ...iod during which at least more than one but fewer than 320 CRC6 errors occurred Button Function Submit Sets any values that have been changed Clear Alarms Resets the alarm conditions and counts to zer...

Страница 40: ...is a method of confirming the integrity of received data Beneath the Performance Current screen are two buttons Performance 24 Hour and Performance 30 Day Clicking either of these buttons will displa...

Страница 41: ...ce based on its electrical signal characteristics used by the equipment connected to the Serial port Values V 35 RS 232 EIA 530 Default V 35 NOTICE V 35 requires the use of an optional cable Refer to...

Страница 42: ...ied by the unit it cannot be set by the user Values Contiguous Alternate Arbitrary Default Contiguous NOTICE Because Alternate Bundling assigns every other channel only half the channels are available...

Страница 43: ...Default Sync Parity Sets the parity bit Values None Odd Even Default None Stop Bit Selects the number of bits required to end the asynchronous character Values 1 2 Default 1 LL The Local Loopback para...

Страница 44: ...vel of CTS to match RTS when the CTS parameter is set to Internal Values Normal 30 ms delay Long 100 ms delay Default Normal Flow Control Selects the type of flow control to be used if the port is asy...

Страница 45: ...en NOTICE Always verify that a DHCP server is available on the network before enabling DHCP Client If on power up a DHCP server is not found a 60 second timeout will occur Client Identifier Displays a...

Страница 46: ...n to view the Unit Access Table Figure 3 12 which specifies up to 10 different IP networks that may access the unit s parameters If no IP networks are supplied any host may access the unit Select any...

Страница 47: ...00 19200 38400 57600 115200 Default 19200 Character Size Selects the number of bits required to make up one asynchronous character Values Five Six Seven Eight Default Eight Diagnostic Messages Enables...

Страница 48: ...e unit to go into alarm on a loss of DTR which occurs when the Serial port detects that the DTR signal is low The DTR Status field indicates the current state of the DTR alarm Services Screen The Serv...

Страница 49: ...reate a usable text file of the captured data In Analyze mode the packet switch will return the data via the Data Line Monitor Packet Table see Figure 3 17 whereas in the Live mode the Data Line Monit...

Страница 50: ...ine the parameters listed above Figure 3 18 Data Line Monitor Details Screen Adding a Service To add a service begin by clicking the Add Service button on the Services screen A new service listed by t...

Страница 51: ...you must supply an endpoint over which to send PPP encapsulated data and that endpoint must be for a Frame Relay DLCI In addition the Service Details screen provides the following user activated butto...

Страница 52: ...on Click the Delete Service button to remove the currently configured service identified by the Service Details screen Deleting the selected service will remove all references to this service These re...

Страница 53: ...on threshold in seconds above which an alarm will report Values 0 900 Default 0 Disabled End of Day Low Utilization Lets you configure as a percent what is considered low utilization at the end of the...

Страница 54: ...s channel is allocated Refer to the Service Table to see how the current services are configured Idle Pattern Selects the DS0 idle pattern sent by the unit and lets the unit determine if the DS0 idle...

Страница 55: ...f DS0 s Percent of DS0s utilized 1 0 100 over the period A 1 indicates an invalid value or unavailable data High Utilization sec Number of seconds 0 900 greater than or equal to the high utilization p...

Страница 56: ...nagement used by the equipment connected to it If set to Auto the unit will learn the link management type and display it on the status portion of this screen Once it discovers the link management typ...

Страница 57: ...rvice has two distinct transmit queues one for normal priority traffic and one for high priority traffic At this time only SCADA and TCP Server traffic are considered high priority and are placed in t...

Страница 58: ...nagement DLCI If there is a DLCI entered and submitted in this field it will be the only DLCI that looks for in band management packets If a value of 0 zero is entered in this field all DLCIs will loo...

Страница 59: ...e sent Status and Alarms Table The table displayed at the bottom of the Frame Relay Service Details screen reports on the status and condition of LMI parameters and on Receive Transmit alarms and thre...

Страница 60: ...s and on Receive Transmit alarms and thresholds Alarm threshold levels may be changed by entering a new threshold value in the appropriate field on the Frame Relay Service Details screen and clicking...

Страница 61: ...anagement octets received by the port FECN Number of Forward Explicit Congestion Notification frames received BECN Number of Backward Explicit Congestion Notification frames received Invalids Number o...

Страница 62: ...menu gives you access to the configuration parameters described in the paragraphs below Figure 3 28 SCADA Details Screen Button Function Submit Sets any values that have been changed All Frame Relay I...

Страница 63: ...a If set to Both the port will process all data Values Input Output Both Default Both SCADA Loopback Determines if and where SCADA will loopback received data Values None Loopback to Network Loopback...

Страница 64: ...Service Details screen Figure 3 31 This menu gives you access to the configuration parameters described in the paragraphs below Figure 3 31 PPP Service Details Screen ACCM The Asynchronous Control Cha...

Страница 65: ...ge Interval The time interval in seconds between CHAP challenges A value of 0 zero disables the periodic authentication challenge Values 0 3600 Default 0 disabled Initiate Negotiation Determines wheth...

Страница 66: ...n Jacobsen compression Default Yes MRU Maximum Receive Units Used to inform the peer that the implementation can receive larger packets or to request that the peer send smaller packets Default Yes HDL...

Страница 67: ...port Receive Frames Number of frames received by the port Octets Number of octets received by the port Mgmt Frames Number of management frames received by the port Mgmt Octets Number of management oc...

Страница 68: ...screen to bring up a PAP Details screen Figure 3 34 in which you can view change or delete the Username and Password for that particular PAP Index Figure 3 34 PAP Details Screen To change the Usernam...

Страница 69: ...for each of 10 entries Figure 3 35 CHAP Table Screen Select an Index number and click the CHAP Details button at the bottom of this screen to bring up a screen in which you can change the Username an...

Страница 70: ...orresponding DLCIs will be saved in the configuration database only after at least one endpoint parameter has been changed and submitted in the Endpoint Details Screen on page 3 41 When in IP Gateway...

Страница 71: ...N When configuring endpoints the name you assign each endpoint in the Name parameter field must be unique within the unit Service The Service Index number from the Service Table on which this DLCI was...

Страница 72: ...remote WANsuite 5165 unit here This DLCI can be used for management only or for management and actual data If this parameter is set a PC connected to the LAN interface of this WANsuite 5165 can reach...

Страница 73: ...ollowing paragraphs To bring up this screen click on a specific DLCI under the DLCI column on the Endpoint Table screen or on the DLCI Details button on the Endpoint Details screen Figure 3 39 DLCI De...

Страница 74: ...R enforcement is configured to Yes the unit will throttle the Committed Burst down to this value when frames are received with the BECN bit set Values 0 1536000 Default 0 Discard Eligible Flag If this...

Страница 75: ...technology if FrameStart Auto Discovery is enabled Round Trip Delay Size Specifies the frame size in bytes of packets making round trip If the Round Trip Delay Size is not configured the Frame Relay...

Страница 76: ...R UAS Threshold Sets the Unavailable Seconds UAS alarm threshold This threshold occurs after the DLCI is unavailable for a specified number of seconds Setting this field to 0 zero disables the alarm U...

Страница 77: ...Index from the pull down menu and clicking the Submit button Alternatively you can display all intervals at once by clicking the All DLCI Intervals button beneath the table The MIB ipadv2 mib describe...

Страница 78: ...e Each rule is established through the Rule Details screen which is accessed by clicking on the appropriate numbered link under the Index column on the Service Aware screen The Service Aware screen Fi...

Страница 79: ...desired rule configuration options and provide the appropriate filter information where required Then press the Submit button at the bottom of the screen Figure 3 43 Rule Details Screen The paragraph...

Страница 80: ...right of the field see next paragraph Filter By IP Port Enables or disables filtering of the IP traffic by the IP port specified in the IP Port field Tx Alarm Threshold Specifies the threshold in bit...

Страница 81: ...od Clicking on the All Traffic Meter Intervals at the bottom of the screen displays the Traffic Meter Statistics for all intervals as defined below Summary Represents the past 24 hours reports the add...

Страница 82: ...SNMP traps generated by the unit The default setting is Public Trap IP Address Accepts the IP address of a network device where alarm reporting traps are to be sent Diagnostics Screen The Diagnostics...

Страница 83: ...error statistics were last cleared ES Displays the number of asynchronous errored seconds that have been detected since the BERT began or since error statistics were last cleared This parameter inclu...

Страница 84: ...he pattern to be transmitted during a test for the selected port Values Marks QRSS 511 2047 215 Spaces Default QRSS NOTICE The 215 pattern is the ITU European version not the ANSI version Test Duratio...

Страница 85: ...nance loopback MLB Far PLB Far LLB Default No Test Loop Down Figure 3 48 Serial Interface Test Details Screen BERT Table on the Serial Interface Test Details Screen The BERT table lets you set the tes...

Страница 86: ...ils Screen The Loop Table at the bottom of the screen lets you specify the type of Loop test to be performed The types of tests available for the Serial interface are shown below Loopback diagrams are...

Страница 87: ...the duration parameters and desired report size in the appropriate fields and then click the Submit button Duration Establishes the amount of time in seconds for which the Top Talkers report will capt...

Страница 88: ...ve been passed across it In addition the Timestamp field indicates the time at which a packet was examined for the specified IP address IP Gateway Details Screen The IP Gateway is a feature of the WAN...

Страница 89: ...m those trusted neighbors will be used to build the internal routing table Values Enable Disable Default Enable RIP Interval Interval for RIP packet to be sent Default is 30 seconds RIP Domain Value r...

Страница 90: ...ss this menu Figure 3 53 by accessing the appropriate numbered link under the Index column on the Circuit Table screen Button Function RIP Parameters Static Routes Table Displays static routes and dyn...

Страница 91: ...t Represents the relative time of treatment of an IP packet This value is used when there are multiple routes to the same destination When two or more routes are available the one with the lowest circ...

Страница 92: ...er the Hello Interval the sooner topological changes are detected but then more traffic is created Values 1 65535 Default 1 OSPF Dead Interval The number of seconds that a router s Hello s have not be...

Страница 93: ...dress Represents the target network that you want this router to reach Target IP Mask Mask of the Target network Next Hop IP address of the next device in the route Cost Cost of using that route Route...

Страница 94: ...o 0 0 0 0 defines THE default route for this unit Next Hop IP Address IP address of the next device in the route Cost Cost of using that route Values 0 65535 Default 1 Route Status Indicates whether o...

Страница 95: ...is used by the router to dynamically associate a high level IP address to a low level physical hardware address ARP packets are only sent across a single physical network There are some cases when an...

Страница 96: ...isabled The ARP Table screen provides the following user activated buttons ARP Details Screen Access this screen Figure 3 58 by clicking on the appropriate numbered link under the Index column on the...

Страница 97: ...Only information coming from Trusted Neighbors is kept by the router Access this menu Figure 3 59 by selecting Trusted Neighbors from the RIP Parameters on the IP Gateway menu This table is useful wh...

Страница 98: ...he ID of the Area represented by an IP address Enable Displays whether the defined Area is enabled or disabled Auth Type Indicates Area validation Stub Displays whether or not the defined area is a St...

Страница 99: ...it point need not be made on a per external destination basis Values Yes No Default No Address Summary A configured address range specifies what addresses are contained within an area When summarizing...

Страница 100: ...area cannot be connected directly to the backbone in this case a virtual link is used Figure 3 63 To establish or maintain the connectivity of the backbone virtual links can be configured through non...

Страница 101: ...ure 3 64 Virtual Link Details Screen The Virtual Link Details screen provides the following user activated buttons TCP Server The TCP Server is a general purpose application that maps arbitrary TCP po...

Страница 102: ...gure 3 66 TCP Connection Details Screen Select the TCP Connection Table to access the screen shown in Figure 3 66 This screen lets you see which addresses and ports are in a listening state and which...

Страница 103: ...connect their networks to the Internet Whether on a global or local port NAT provides translation only upon receipt of a packet which NAT will translate not translate or filter depending on the user s...

Страница 104: ...ired The default is NAPT Global IP Addr Global IP Address used in NAPT mode Must be a valid Class C address Default is LAN IP Address Global Mask IP Mask associated with defined Global IP Address Defa...

Страница 105: ...ence Delta Timer The maximum time in seconds NAT will use resources when managing TCP Packet Sequencing Values 0 65535 Default 180 UDP Timer The maximum time in seconds NAT will use resources for a UD...

Страница 106: ...is 0 Server Port Decimal IP Port of the local TCP Server This port is usually the same as the Global Port Default is 0 Server Address IP Address of the local TCP Server Default is 0 0 0 0 The Static T...

Страница 107: ...t is 0 Server Address IP Address of the local UDP Server Default is 0 0 0 0 The Static UDP Translation Table screen provides the following user activated buttons You can configure or change the above...

Страница 108: ...ination address different from the global Internet network address will be processed by the IP Gateway and may be routed to another port If this parameter is set to Disable no packet with a destinatio...

Страница 109: ...nfiguration Protocol DHCP DHCP provides a mechanism through which computers using TCP IP can obtain protocol configuration parameters automatically through the network The most important configuration...

Страница 110: ...vention from a centrally managed DHCP server DHCP is available on the 10 100 Ethernet port only NOTICE You must Save and Restart for any changes in DHCP configuration parameters to take effect NOTICE...

Страница 111: ...t is 0 0 0 0 Secondary DNS IP Addr If requested by DHCP client the client then uses this secondary address to resolve names of IP addresses Default is 0 0 0 0 The DHCP Server Details screen provides t...

Страница 112: ...IP address will always be used for a given PC provided its MAC address is known These parameters are configured on the Static Entry Details screen Figure 3 82 accessed by selecting a numbered link fr...

Страница 113: ...addresses available for DHCP clients These parameters are configured on the IP Address List Details screen Figure 3 84 accessed by clicking on a numbered link in the Index column Figure 3 83 IP Addres...

Страница 114: ...tivated buttons IP Address Status Table Screen The IP Address Status Table screen Figure 3 85 displays a list of all current DHCP clients Figure 3 85 IP Address Status Table Screen MAC Address MAC Add...

Страница 115: ...ly forward packets from one network to others however Rather it learns all local physical addresses and forwards packets based on those learned tables This greatly reduces the number of broadcasted pa...

Страница 116: ...ult 300 s The Bridge Details screen provides the following user activated buttons Figure 3 87 Bridge Port Table The Bridge Port Table screen lets you view the parameters described below the Bridge Por...

Страница 117: ...this port The lower the value the higher the priority Path Cost Value of efficiency of the path to the port A higher path cost indicates a slower link State If Enabled reflects the state of the port...

Страница 118: ...own MAC address and Learned the unit learned MAC address is directly accessible by this port Simple Mail Transfer Protocol SMTP Use the SMTP Details Screen Figure 3 90 to configure the SMTP function o...

Страница 119: ...ress Recipient 1 5 E mail addresses of recipients of event notifications i e sales verilink com or support verilink com Encryption If a DLCI encapsulation is set for FRF 17 instead of RFC1490 all data...

Страница 120: ...ou allow sufficient time for the download to occur Canceling the download before it has fully executed will result in the new software NOT being installed into the unit Upload Save The Upload Save scr...

Страница 121: ...d are digits 0 9 and letters A Z and a z for a total of 62 distinct characters Figure 3 93 Password Screen To change either the Admin or Read Only password you must enter it once in the New Password f...

Страница 122: ...ent remote in band management of a WANsuite 5165 unit The first is to use the local router to route management frames Web browser or SNMP between the local LAN and the remote unit The second is to use...

Страница 123: ...ddress assignment is also independent from the routers The PC used for management must have the local WANsuite 5165 s IP address as its gateway address so that it can reach all remote WANsuite 5165s F...

Страница 124: ...3 94 W A N s u i t e 5 1 6 5...

Страница 125: ...port or remotely through a TELNET session To access the VT 100 screens locally verify the Supervisory type is tty and the Supervisory port speed matches the terminal emulation program that s being use...

Страница 126: ...mmands is provided Perform each command by pressing a letter key while holding down the Ctrl key You may use the alternative commands shown in the following table and keyboard commands interchangeably...

Страница 127: ...be replaced by the new characters To edit an existing entry rather than replace it press the right arrow key to move the cursor to the point that needs editing You may insert characters or delete them...

Страница 128: ...Location Read write field that holds the unit s location FrameStart ID Read write field that holds the unit s ID that uniquely identifies the unit and is used in the FrameStart applications Blank Fiel...

Страница 129: ...ing the space bar you may toggle through the options to select the desired maintenance reset Default TDM Configuration Default Packet Configuration Default Packet 2 Configuration Default Packet 3 Conf...

Страница 130: ...sing Ctrl U after approximately 10 seconds to restore communications Save and Restart Selecting Save and Restart will display a confirmation menu similar to that shown in Figure 4 4 Select yes to save...

Страница 131: ...nfig Screen Function Network 2 Only In the Slaved function Network 2 is slaved and can only be mapped to Network 1 In the Network function Network 2 functions as an independent network but can only be...

Страница 132: ...ng source to synchronize the unit s internal timing generators In all cases slips are controlled to occur on frame boundaries at the Network ports when timing synchronization is lost The options are a...

Страница 133: ...able alarm reporting set all fields to 0 zero The 15 minute time frame is not based on the TR 54016 or T1 403 interval boundaries but is a time window based on the accumulated counts over the previous...

Страница 134: ...he terminal equipment when an improper signal is received from the facility or upon receipt of unframed all ones The default is 0 seconds Disabled Reset Timer The status table also provides an option...

Страница 135: ...ES A Bursty Error Seconds BES is a 1 second period during which at least more than one but fewer than 320 CRC6 errors occurred LOFC The Loss of Frame Count LOFC represents the number of time a loss of...

Страница 136: ...directly to the WANsuite 5165 s Data 1 and Data 2 ports respectively The Serial screens let you view and make changes to the unit s Serial interface configuration as described in the paragraphs below...

Страница 137: ...the Serial port connects to a DTE device such as a FRAD or a router the Mode parameter must be set to DCE If this port connects to a DCE device such as a DSU CSU this parameter must be set to DTE vali...

Страница 138: ...Rate Channel Rate The unit can operate at any data rate that is a multiple of 56 or 64 kbps If x64K is selected the ones density requirements of the T1 network line must be ensured If x56K is selected...

Страница 139: ...ccurs when the Serial port detects that the DTR signal is low Values Enable Disable Default Disable DTR Alarm Status Lets you view the current DTR Alarm status Format Selects the port s operating mode...

Страница 140: ...parameter determines the source from which the unit reads the RTS signal status If set to Normal the unit gets RTS from the DTE on the Serial interface If set to Forced True RTS is always perceived as...

Страница 141: ...ier for a specific IP address Ethernet Enables or disables a remote unit s Ethernet port Physical Address Displays unique MAC address NOTICE Always verify that a DHCP server is available on the networ...

Страница 142: ...rts only asynchronous character formats Figure 4 14 Supervisory Configuration Screen The Supervisory screen lets you view and change the Supervisory port speed The Supervisory port only supports async...

Страница 143: ...ault Disable DTR Alarm Status Lets you view the current DTR Alarm status Diagnostic Messages Enables the Supervisory port to send out diagnostic messages upon power up Values Enable Disable Default En...

Страница 144: ...otiations Up The service is ready to pass data Idle The service has nothing to do The Service Table screen displays the available services listed by Index number To view more detailed information abou...

Страница 145: ...d and captured Pattern Displays which specific pattern is being searched for Mask Displays the bits the unit is looking for Offset Displays the offset in the packet that matches the pattern You may vi...

Страница 146: ...the Data Line Monitor Packet Table whereas in the Live mode the Data Line Monitor Packet Table will appear empty for SNMP calls Buffer Management Displays whether displayed data is set to Wrap or Stop...

Страница 147: ...ual interface you must supply an endpoint over which to send PPP encapsulated data and that endpoint must be for a Frame Relay DLCI Type Selecting one of the services listed under the Type column will...

Страница 148: ...econds that an alarm condition must not be present before an alarm is reset Zero 0 indicates the Alarm Reset Timer is disabled Values 0 900 Default 30 High Utilization Lets you configure as a percent...

Страница 149: ...kbps Values 56K 64K Default 64K Service Specifies the service to which this channel is allocated Refer to the Service Table to see how the current services are configured Idle Pattern Selects the DS0...

Страница 150: ...history is displayed Timestamp System up time value during which the utilization historical period was completed Utilization of DS0 s Percent of DS0s utilized 1 0 100 over the period A 1 indicates an...

Страница 151: ...the user side of a User to Network interface If it is connected to a FRAD router the Interface Type should be set to NI as it is the network side of a User to Network interface If it is connected to...

Страница 152: ...r of link reliability and protocol errors that can occur during the sliding event monitor count defined by N3 If this count is exceeded the port is declared inactive Values 1 255 Default 3 N3 This cou...

Страница 153: ...ult 0 Enforce CIR and Be If this parameter is set to Yes the unit will enforce Committed Information Rate and Excess Burst according to the Link Injection Parameter Values No Yes Default No NOTICE The...

Страница 154: ...one for high priority traffic At this time only SCADA and TCP Server traffic are considered high priority and are placed in the high priority queue All other types of traffic are placed in the normal...

Страница 155: ...elay Statistics prompt to bring up a table Figure 4 25 that reports on the status and condition of LMI parameters and on Receive Transmit alarms and thresholds Alarm threshold levels may be changed by...

Страница 156: ...elay Port Statistics Screen Transmit Frames Number of frames transmitted by the port Octets Number of octets transmitted by the port Mgmt Frames Number of management frames transmitted by the port Mgm...

Страница 157: ...eived in frame relay LMI status inquiries Stat Responses Number of octets received in frame relay LMI status responses Invalid LMIs Number of invalid Local Management Interface frames received Through...

Страница 158: ...Default 192 168 1 3 Virtual PPP Over Endpoint name over which to send PPP encapsulated data i e PPP over Frame Relay Valid only when the PPP interface is Virtual Auth Challenge Interval The time inter...

Страница 159: ...ression Compresses PPP protocol headers Default Yes IPCP Compression Compresses TCP headers using Van Jacobsen compression Default Yes MRU Informs the peer that the implementation can receive larger p...

Страница 160: ...tets transmitted by the port Rx Frames Number of frames received by the port Rx Octets Number of octets received by the port Average Average bandwidth in bps used by the port Peak Peak bandwidth in bp...

Страница 161: ...elete the Username and Password for a selected PAP Index delete the character string displayed in both fields leaving them blank and press the Esc key CHAP Table From the PPP Service Details screen se...

Страница 162: ...listed below Figure 4 31 SCADA Service Details Screen Message Size Maximum number of characters to buffer before sending a frame Values 0 1024 Default 256 Idle Character Delay Maximum number of idle...

Страница 163: ...all SCADA statistics by selecting the SCADA Clear Statistics prompt at the bottom of the screen Select the SCADA Device List prompt to bring up a screen that shows the mapping between SCADA devices an...

Страница 164: ...cs for Layer 3 and above that do not map to a specific service or interface Figure 4 34 Applications Screen Endpoint Table Screen The Endpoint Table Figure 4 35 describes all endpoints terminating in...

Страница 165: ...A Sn are reserved by the system These system generated endpoints cannot be modified Figure 4 35 Endpoint Table Screen You can add an endpoint in the Add Endpoint field and when the screen refreshes yo...

Страница 166: ...onfiguring endpoints the name you assign each endpoint in the Name parameter field must be unique within the unit Service This is the Service Index number from the Service Table on which this DLCI was...

Страница 167: ...te WANsuite 5165 unit here This DLCI can be used for management only or for management and actual data If this parameter is set a PC connected to the LAN interface of this WANsuite 5165 can reach a re...

Страница 168: ...ement RFC 1490 must be the encapsulation method Protocol Encapsulation This is the type of encapsulation used by the FRAD router connected to the unit Values RFC 1490 Proprietary Default RFC 1490 Prop...

Страница 169: ...e the unit will send FrameStart discovery and delay frames on this DLCI and will report the state of the remote Verilink unit with FrameStart technology It will also send SOS frames when the FRAD rout...

Страница 170: ...CN BECN When a frame is received with congestion bit set this parameter is set to Yes It is set back to No when a frame is received without congestion bit set Values Yes No Default No CIR Threshold Se...

Страница 171: ...DLCI statistics If the unit is powered on at 01 00 PM the first interval will be completed at 01 15 PM subsequent intervals would be completed at xx 30 xx 45 xx 00 and xx 15 Interval 1 is always the l...

Страница 172: ...fers to Frame Delivery Ratio which is the ration of successful frame receptions to attempted frame transmissions DDR refers to Data Delivery Ratio or the ratio of successful payload bytes received to...

Страница 173: ...rough the Rule Config screen which is accessed by selecting Rule Details The Service Aware screen Figure 4 41 provides a table showing these filtered packet counts for up to 10 rules This table indica...

Страница 174: ...e rule applies Filter By DLCI Enables or disables filtering of the IP traffic in accordance with the previously specified DLCI NOTICE To use this filter you must specify both the Service and DLCI para...

Страница 175: ...f frames and octets sent over a DLCI that have been counted in accordance with the Service Aware rule that has been established for a Service As such it is frame relay specific i e DLCIs only occur in...

Страница 176: ...as many as eight destinations on your network The unit will report each alarm by transmitting an SNMP trap to each non zero Trap IP address The SNP Details screen Figure 4 44 lets you configure the S...

Страница 177: ...p Type Describes the type of loop test if any performed on the selected interface Setting Displays the bandwidth on which you wish to perform the BERT Pattern Specifies the pattern to be transmitted d...

Страница 178: ...he ANSI version Test Duration Specifies the length of time for which the test should run for the selected port Values 15 minutes 30 minutes 1 hour 24 hours Continuous Default 15 minutes From this scre...

Страница 179: ...divided by the number of seconds accumulated in Elapsed Time Loop Table on Network Interface Test Details Screen The Loop Table at the bottom of the screen lets you specify the type of Loop test to b...

Страница 180: ...splays the total number of bit errors detected since the test began or since error statistics were cleared Errored Seconds Displays the number of asynchronous errored seconds that have been detected s...

Страница 181: ...error captured by the trap Trap Number and the date and time that the trap was stored Time Stamp Figure 4 48 Trap Log Screen Top Talkers Screen Selecting Top Talkers displays the Top Talkers screen F...

Страница 182: ...ys the actual number of IP addresses identified as Top Talkers in the generated report The maximum report size is 20 Start Time Displays the time at which the Top Talkers report was initiated based on...

Страница 183: ...esses required Figure 4 50 IP Gateway Screen RIP Parameters RIP Enable Globally enables RIP1 RIP2 or No RIP Default is RIP 2 Values Disable Enable RIP1 Enable RIP2 Default Enable RIP2 RIP Trust Neighb...

Страница 184: ...nique router ID Default is the LAN IP address of the unit The IP Gateway screen provides the following user prompts that may be selected by pressing the Enter key Circuit Table Screen This menu shows...

Страница 185: ...k of the circuit Max Transmit Unit Maximum transmit unit this circuit will send at any one time Cost Represents the relative time of treatment of an IP packet This value is used when there are multipl...

Страница 186: ...ame network The smaller the Hello Interval the sooner topological changes are detected but then more traffic is created Values 1 65535 Default 1 OSPF Dead Interval The number of seconds that a router...

Страница 187: ...the configuration parameters of a given route Figure 4 54 Route Details Screen Field Description Endpoint Endpoint name or interface through which to send the IP packet to reach the Target IP Address...

Страница 188: ...or disabled Dynamic Route Table Screen Access this menu by selecting the Static Route Table on the IP Gateway menu and then selecting Dynamic Route Table This table shows all known dynamic and static...

Страница 189: ...te a Static ARP Table entry because an ARP entry is always associated with a circuit The static ARP table is useful when a Host does not respond to an ARP request Access this menu by selecting Static...

Страница 190: ...00 00 00 00 00 00 ARP Status Displays whether this static ARP is enabled or disabled Values Enable Disable Default Enable Trusted Neighbors Screen The Trusted Neighbors feature can be used to store RI...

Страница 191: ...Index column This screen lists all IP addresses of Trusted Neighbors Figure 4 59 Neighbor Details Screen Area Table Screen An Area allows growth and makes the networks at a site easier to manage An ar...

Страница 192: ...ils Screen Field Description Area ID Displays the ID of the Area represented by an IP address Ena Displays whether the defined area is enabled or disabled Auth Type Indicates Area validation Stub Disp...

Страница 193: ...Mask of the summary to be added Values 0 0 0 0 255 255 255 255 Default 0 0 0 0 Advertise Describes the local state of a router or network This includes the state of the route s interfaces and adjacenc...

Страница 194: ...defined by the following two parameters The Router ID of the virtual link s other endpoint The non backbone area across which the virtual link goes through Figure 4 62 Virtual Link Table Screen The fi...

Страница 195: ...ze on page 4 30 for more details The TCP Server is a general purpose application that maps arbitrary TCP port numbers to non TCP IP devices that have been assigned an endpoint See the Endpoint Table S...

Страница 196: ...e TCP Connection Table prompt on the TCP Server screen to access the screen shown in Figure 4 66 This screen lets you see which addresses and ports are in a listening state and which are already estab...

Страница 197: ...sers cost effectively and efficiently connect their networks to the Internet Whether on a global or local port NAT provides translation only upon receipt of a packet which NAT will translate not trans...

Страница 198: ...d to a Class C public address on the Global side In other words if there are 30 hosts on the private Local side 30 public Global addresses are required The default is NAPT Global IP Addr Global IP Add...

Страница 199: ...hen attempting to close a TCP connection Values 0 65535 Default 0 TCP Disconnected Timer The maximum time in seconds NAT will use resources when attempting to disconnect from TCP Values 0 65535 Defaul...

Страница 200: ...Default is 0 Server Port Decimal IP Port of the local TCP Server This port is usually the same as the Global Port Default is 0 Server Address IP Address of the local TCP Server Default is 0 0 0 0 The...

Страница 201: ...Screen Enable Enables or disables the NAT port Default is Enable Default Translation Forces translation on a specific IP port regardless of the source IP Address If Default Translation is set to Enabl...

Страница 202: ...ss Default is the value defined in the IP Gateway Circuit Table Endpoint The Endpoint name of the circuit associated with the LAN or WAN port Default is LAN for the first port The Add New prompt lets...

Страница 203: ...igure 4 75 allows static mapping of global UDP Server ports to a local host IP address port combination The parameters described below enable access to UDP Servers on the private corporate network beh...

Страница 204: ...computer is attached and that is not assigned to any other computer on that network If a computer moves to a new network it must be assigned a new IP address for that new network DHCP can be used to m...

Страница 205: ...ed amount of time to ensure the IP address is not given to another PC Default is 600 seconds Primary DNS IP Addr If requested by DHCP client the client then uses this address to resolve names of IP ad...

Страница 206: ...ost name NOTICE You must Save and Restart for the new Server name to become active Static Entries Screen The Static Entries screen Figure 4 79 lists static IP addresses associated with MAC addresses T...

Страница 207: ...efined on this screen Mask Mask associated with the IP Address shown on the screen Host Name Name given to the DHCP client Select Add New to add a static entry IP Address List Screen The IP Address Li...

Страница 208: ...this screen Status Provides IP Address Status Bridge A Bridge operates at the physical network layer connecting two or more networks and forwarding packets between those networks For example a Bridge...

Страница 209: ...s the group address for the Bridge Protocol Data Unit BPDU transfer between bridges Values Any valid Group Multicast MAC Address Default 0180C2000000 Bridge ID Consists of a bridge priority and its ow...

Страница 210: ...ble prompt displays the screen shown below in Figure 4 83 Selecting a number in the Index column of the Bridge Port Table will bring up the Bridge Port Details screen Figure 4 84 which displays and in...

Страница 211: ...rity associated with this port The lower the value the higher the priority Path Cost Value of efficiency of the path to the port A higher path cost indicates a slower link State If Enabled reflects th...

Страница 212: ...s How the address was included in the forwarding table The two possibilities include Self the unit s own MAC address and Learned the unit learned MAC address is directly accessible by this port Simple...

Страница 213: ...lled in NOTICE There can be no blank space s in the Mail From address Recipient 1 5 E mail addresses of recipients of event notifications i e sales verilink com or support verilink com Encryption If a...

Страница 214: ...4 90 W A N s u i t e 5 1 6 5 Figure 4 87 Encryption Details Screen...

Страница 215: ...protection fused input output Jitter Control per TR 62411 and T1 403 Timing Source With Function parameter on Network 2 screen in Slaved mode options are Internal Network 1 Network 2 Serial 1 Serial...

Страница 216: ...ps where n 1 32 or nx56 kbps where n 1 31 or Asynchronous 1200 2400 4800 9600 19200 38400 57600 115200 bps Clocking Internal External Management Interfaces 10 100 Ethernet Connection 8 pin modular Net...

Страница 217: ...Network Framer Port Logic Nx64 Port LLB WANsuite 5165 Internal Logic Network Port T1 Network Framer Port Logic Nx64 Port PLB WANsuite 5165 Internal Logic Network Port T1 Network Framer Port Logic Nx6...

Страница 218: ...5 2 ounces 430 91 grams Environmental Operating Temp 32 to 122 F 0 to 50 C Storage Temp 4 to 149 F 20 to 65 C Humidity 95 maximum non condensing Frame Relay Statistics Collected in 96 15 minute Interv...

Страница 219: ...es Tx Rx mgmt octets Rx invalid frames Peak average throughput Industry Listings FCC Compliance Part 15 Class A Subpart B Part 68 U S Safety UL 1950 3rd edition Canadian Safety CSA C22 2 No 950 95 Ind...

Страница 220: ...Serial Supervisory Cable RJ 11 to DB 9 WANsuite Documentation CD Description Serial DCE Cable DB 25 DB 25 M M pin pin EIA 530 RS 232 6 ft Serial DCE Cable DB 25 Winchester 34 pin V 35 M M pin pin 5 f...

Страница 221: ...7 B 7 Data Carrier Detect DCD Input 8 8 F 8 Balanced Receiver Clock B RC Input 12 X 9 Balanced Data Carrier Detect B DCD Input 10 10 Balanced External Transmitter Clock B ETC Balanced Transmitter Clo...

Страница 222: ...Data Carrier Detect DCD Output 8 8 F 8 Balanced Receiver Clock B RC Output 9 X 9 Balanced Data Carrier Detect B DCD Output 10 10 Balanced External Transmitter Clock B ETC Input 11 W 11 Balanced Transm...

Страница 223: ...ays the pinout assignments Supervisory Port Pin Assignments The LOCAL Supervisory port interface is a standard RJ 11 6 pin modular jack The table below displays the pinout assignments 3 Data In 6 Data...

Страница 224: ...A 10 W A N s u i t e 5 1 6 5...

Страница 225: ...ss write access and trap access the community string sent with an SNMP trap Configuration of these community strings within the WANsuite 5165 is accomplished via the HTTP web browser interface refer t...

Страница 226: ...Relay PPP and Service Aware configuration and statistics ipstart mib MIB module for synchronous PPP Monitor router mib provides configuration of OSPF router hdsl2 mib MIB module for HDSL ipaddhcp mib...

Страница 227: ...m the notPresent state This other state is indicated by the included value of ifOperStatus ifIndex ifAdminStatus ifOperStatus linkUp snmpTraps 4 A linkUp trap signifies that the SNMP entity acting in...

Страница 228: ...a higher level line status change i e ds3 then no traps for the ds1 are sent dsx1LineStatus dsx1LineStatusLastChange frDLCIStatusChange frEnterprise 1 This trap indicates that the indicated Virtual C...

Страница 229: ...hdsl2ShdslPerfESThreshTrap 3 This trap indicates that the errored seconds threshold as per the hdsl2ShdslEndpointThreshES value has been reached exceeded for the HDSL2 SHDSL segment endpoint identifi...

Страница 230: ...fNumRepeaters hdsl2ShdslLoopbackFailure 9 This trap indicates that an endpoint maintenance loopback command failed for an HDSL2 SHDSL segment ifIndex hdsl2ShdslInvIndex hdsl2ShdslEndpointSide hdsl2Shd...

Страница 231: ...NeighborPresent in the hdsl2ShdslEndpointCurrStatus object for this endpoint has changed ifIndex hdsl2ShdslInvIndex hdsl2ShdslEndpointSide hdsl2ShdslEndpointWirePair hdsl2ShdsllocalPowerLoss 16 This t...

Страница 232: ...old is the number of frames in excess of Be ipadDLCItxExBeAlarm ipadDLCIRxCongestionExceeded 25005 This trap is sent out when the Rx congestion threshold has been exceeded This threshold is the number...

Страница 233: ...n SOS condition ipadDLCIremoteEquipActive ipadDdsLOSSAlarmDeclared 25020 This trap is sent out when a Loss of Signal Seconds alarm is declared ddsNetLOSCount ipadDdsOOFSAlarmDeclared 25021 This trap i...

Страница 234: ...files for Castle Rock Computing s SNMPc 2 Start the SNMP manager if it is not already running Select one of the menu selections or selection subheadings that contains the SNMP MIB operations this is O...

Страница 235: ...ED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT WILL VERILINK S LIABILITY TO BUYER OR ANY SUCCESSOR TO BUYER EXCEED THE PRICE PAID FOR THE APPLICABLE GOODS IV LIMITED WARRANTY CONDITIONS The Limited...

Отзывы: