DIDCSU T1 Version
3-10
Verilink DIDCSU 2912 User Manual
Table 3-5
FDL Configuration Menu
Command
Description
Options
Sn
FDL Standard: Specify if you want to use the Bellcore 54016 standard,
the ANSI T1.403 standard, or both (BOTH is recommended).
1) TR54016
2) T1.403
3) BOTH
Mn
FDL Mode: Specify TERM (Terminated) if you want to end the FDL
transmission at this node. Specify PASS if you want the FDL transmission
to continue to another node.
PASS is not yet supported.
1) TERM
2) PASS
Pn
• Poll Mode: Specify if you want FDL to poll for alarms at the far end.
• Poll: The near-end CSU automatically polls the far-end CSU for alarms
every 4 seconds and report these alarms.
• No Poll: This disables alarm polling at both ends. Select this option
when the nodes at both ends are connected and both nodes report
local alarms.
• Unsolicit: The far-end automatically sends its alarm status (when it
detects an LOS) to the near-end. Select this option for far-end CSU
circuit element when the near-end CSU is set to Poll.
1) POLL
2) NO POLL
3) UNSOLICIT
Cn
PRM C/R bit: Performance Report Message Command/Response as
defined in the ANSI T1.403 specification.
Specify User to set the bit to 0, indicating that you are the PRM source
terminal. Specify TELCO to set the bit to 1, indicating that the phone
company is the PRM source. Phone companies usually set it to Telco, non
phone companies set it to User. To disable this option, choose None.
1) NONE
2) USER
3) TELCO
In
Idle Pattern: Use this option to select the idle pattern code when there is
no user data on the net. Depending on your network or telco, choose
either the All-ones or Flags option.
The signal you choose is transmitted continuously until a message is
sent. Once the message completes transmission, it reverts to the signal
of choice:
• All-ones signal: 11111111.
• Flags signal: 01111110.
1) ALL ONES
2) FLAGS
An
Send/Rec LLB BOP: Use this option to enable the Line Loopback Bit-
Oriented Protocol (LLB BOP) if you want to use FDL loopbacks to test the
T1 line (ESF only).
Yes or No
(Y/N)
Bn
Send/Rec PLB BOP: Use this option to enable the Payload Loopback Bit-
Oriented Protocol (PLB BOP) if you want to use FDL loopbacks to test the
far-end CSU (ESF only).
Yes or No
(Y/N)
X
Exit the
FDL Configuration Menu
.
Содержание DIDCSU 2912
Страница 18: ...DIDCSU 2912 Overview 1 12 Verilink DIDCSU 2912 User Manual...
Страница 40: ...DIDCSU 2912 Quick Set Up 2 22 Verilink DIDCSU 2912 User Manual...
Страница 106: ...Index 4 Verilink DIDCSU 2912 User Manual U UAS 4 22 Unavailable Seconds 4 22 V view circuits 3 32 4 29...
Страница 107: ...VERILINK CORPORATION 127 JETPLEX CIRCLE MADISON ALABAMA 35758 TEL 800 837 4546 October 1999 P N 880 502646 001 E1...