![Verilink DIDCSU 2912 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/verilink/didcsu-2912/didcsu-2912_manual_1004285047.webp)
DIDCSU T1 Version
Verilink DIDCSU 2912 User Manual
3-7
Configuring the
T1 Port
To access the
T1 Port Configuration Menu
, enter “P” from the
Configuration Menu
.
To change a port configuration, enter the command letter followed
by the port number. For example, to remove Port 2 from service,
command
I
n
, enter “
I
2” (
n
is a variable that represents the port
number).
Figure 3-5 T1 Port Configuration Menu
Table 3-4
T1 Port Configuration Menu Parameters
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
PORT 1 PORT 2
PORT 1 PORT 2
PORT 1 PORT 2
PORT 1 PORT 2
In) In Service NO YES
In) In Service NO YES
In) In Service NO YES
In) In Service NO YES
Fn) Frame Format SF ESF
Fn) Frame Format SF ESF
Fn) Frame Format SF ESF
Fn) Frame Format SF ESF
Ln) Line Coding AMI B8ZS
Ln) Line Coding AMI B8ZS
Ln) Line Coding AMI B8ZS
Ln) Line Coding AMI B8ZS
Bn) Line Build Out 0db 0db
Bn) Line Build Out 0db 0db
Bn) Line Build Out 0db 0db
Bn) Line Build Out 0db 0db
NDn) Network Density NONE NONE
NDn) Network Density NONE NONE
NDn) Network Density NONE NONE
NDn) Network Density NONE NONE
NLn) Network Initiated Loop NO NO
NLn) Network Initiated Loop NO NO
NLn) Network Initiated Loop NO NO
NLn) Network Initiated Loop NO NO
An) Alarm Declare Time(sec) 0 0
An) Alarm Declare Time(sec) 0 0
An) Alarm Declare Time(sec) 0 0
An) Alarm Declare Time(sec) 0 0
DLn) FDL Enable NO NO
DLn) FDL Enable NO NO
DLn) FDL Enable NO NO
DLn) FDL Enable NO NO
PRM Enable NO NO
PRM Enable NO NO
PRM Enable NO NO
PRM Enable NO NO
En) Enable Inband/ISDN both dis both dis
En) Enable Inband/ISDN both dis both dis
En) Enable Inband/ISDN both dis both dis
En) Enable Inband/ISDN both dis both dis
Sn) Inband Timeslot 1 1
Sn) Inband Timeslot 1 1
Sn) Inband Timeslot 1 1
Sn) Inband Timeslot 1 1
F) FDL configuration
F) FDL configuration
F) FDL configuration
F) FDL configuration
T) Timing
T) Timing
T) Timing
T) Timing
X) Exit this screen
X) Exit this screen
X) Exit this screen
X) Exit this screen
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
Command
Description
Options
In
In Service: Use this option to place the port on line.
Yes or No
Fn
Frame Format: Choose SF (Superframe) or ESF
(Extended Superframe
Format) as dictated by the type of T1 facility provided. Contact your circuit
provider if the type of T1 framing is not known.
SF format provides traffic signaling and framing. It is sometimes referred to
as D4.
ESF format provides cyclic redundancy check, performance monitoring, data
checking, and link bits (Facilities Data Link, or FDL).
1) SF
2) ESF
Содержание DIDCSU 2912
Страница 18: ...DIDCSU 2912 Overview 1 12 Verilink DIDCSU 2912 User Manual...
Страница 40: ...DIDCSU 2912 Quick Set Up 2 22 Verilink DIDCSU 2912 User Manual...
Страница 106: ...Index 4 Verilink DIDCSU 2912 User Manual U UAS 4 22 Unavailable Seconds 4 22 V view circuits 3 32 4 29...
Страница 107: ...VERILINK CORPORATION 127 JETPLEX CIRCLE MADISON ALABAMA 35758 TEL 800 837 4546 October 1999 P N 880 502646 001 E1...