Verderflex iDura 10 Скачать руководство пользователя страница 6

iDura 05-35

Version 1.0v-11/2020

© Verder International B.V

6 | Page

Warranty

  

The warranty is void if the customer fails to follow any 

Instruction, Warning or Caution in this document. Verder 

has made every effort to illustrate and describe the prod

-

uct in this document. Such illustrations and descriptions 

are however, for the sole purpose of identification and 

do 

not

 express or imply a warranty that the products are mer

-

chantable or fit for a particular purpose, or that the prod

-

ucts will necessarily conform to the illustration or descrip-

tions.

 

Obtain the manufacturer’s approval prior to carrying out 

any  modifications,  repairs  or  alterations  during  the  war

-

ranty period. Only use genuine parts or parts that have 

been approved by the manufacturer.

 

For further details regarding warranty, refer to terms and 

conditions.

2.2.3  Obligation of Personnel

 

It is imperative that the instructions contained in this 

manual are complied with by the operating personnel 

at all times.

u

  Pump and associated components:

– 

Do not lean or step on them or use as climbing aid

– 

Do not use them to support boards, ramps or beams

– 

Do not

 use them as a fixing point for winches or sup

-

ports

– 

Do not de-ice using gas burners or similar tools

u

  Do not remove the safety guarding for hot, cold or moving 

parts during operation.

u

  Reinstall the safety equipment on the pump as required 

by regulations after any repair / maintenance work on the 

pump.

2.3   Specific Hazards

2.3.1  Hazardous Pumped Liquids

 

Follow the statutory safety regulations when handling haz

-

ardous pumped liquids (e.g. hot, flammable, poisonous or 

potentially harmful).

 

Use appropriate Personal Protective Equipment when car

-

rying out any work on the pump.

2.3.2   Lubricants

 

Ensure that the lubricant and pumped liquid are compat- 

ible with each other. This is a precautionary measure in 

case of accidental hose burst whereby the pumped liquid 

comes in contact with the lubricant. (

g

 Refer datasheet 

for lubricant to ensure compatibility and also refer to (

g

 11 

Technical Specifications) for specific lubricant limitations)

2.3.3   Sharp Edges

 

Pump parts, such as the shims and impellers, can be  

sharp

– 

Use protective gloves when carrying out any work on 

the pump

Содержание iDura 10

Страница 1: ...Peristaltic Industrial Hose Pump Supplementary Document Version 1 0v 11 2020 Print No 01 iDura 5 7 10 15 25 35 ...

Страница 2: ...ion 1 0v 11 2020 Print No 01 iDura 5 7 10 15 25 35 The information in this document is essential for the safe operation of Verderflex i Dura pumps This document must be read and understood thoroughly prior to installation of unit electrical con nection and commissioning ...

Страница 3: ...lectrical Connection 4 2 Electric Shock Hazard 4 3 Connecting to the Power Supply 5 Operation supplementary 6 Maintenance 6 1 Hose Change 6 1 1 Draining Lubricant 6 1 2 Hose Change Using Inverter 6 1 3 Hose Change Manually 6 1 4 Re installing the Hose Port Flanges Lubricant Refill and Fitting the Inspection Window 7 Service and Inspection of Electrical Components 8 Troubleshooting for the iDura In...

Страница 4: ...Operating Company u Keep this manual available at the operating site of the pump u Ensure that personnel read and follow the instructions in this manual and any other applicable documents especially all safety instructions and warnings u Observe any additional rules and regulations referring to the system Qualified personnel fitter u Read observe and follow this manual and the other applicable doc...

Страница 5: ...cific headings Operate the pump only if it and all associated systems are in good functional condition Only use the pump and inverter as intended fully aware of safety and risk factors involved and the instructions in this manual Keep this manual and all other applicable documents complete legible and accessible to personnel at all times Refrain from any procedure or action that would pose a risk ...

Страница 6: ...ted components Do not lean or step on them or use as climbing aid Do not use them to support boards ramps or beams Do not use them as a fixing point for winches or sup ports Do not de ice using gas burners or similar tools u Do not remove the safety guarding for hot cold or moving parts during operation u Reinstall the safety equipment on the pump as required by regulations after any repair mainte...

Страница 7: ... 85 non condensing Out of direct sunlight Frost free temperature range 5 to 45 C Vibration free Dust free 2 Depending on these conditions it may be advisable to place a moisture absorbing product such as Silica gel inside the pump s housing or to coat the pump s inner surfaces with moisture repelling oil such as WD40 whilst the pump is stored 3 Hoses should be stored as supplied in their wrapper a...

Страница 8: ...erience They must care fully read this safety information and the instructions in this Guide and follow all information regarding transport storage installation and use of the Inverter including the specified environmental limitations 3 Do not perform any flash test or voltage withstand test on the Inverter 4 In order to protect inverter and motor from high voltage or transient damage it is recomm...

Страница 9: ...osi tion and that power is available to the inverter 2 Switch on the inverter using the built in isolator switch and check no errors are displayed on screen 2 3 Directional switch governs which direction the pump will turn When set to the right position the pump should turn clockwise if not refer to g 4 3 Connecting to the Power Supply 4 Speed dial allows governance over pump rotor speed be tween ...

Страница 10: ...of both clamp rings where fitted 2 Set directional dial to whichever direction is preferable and the speed dial to minimum setting 3 The motor will slowly drive out the hose If at this point you are performing inspection on the rotor or pump cavity turn off inverter and lock out using an appropriate lock out tag out 4 Clean the pump housing 5 Inspect the flanges for damage and signs of wear 6 1 3 ...

Страница 11: ...onfiguration 1 E TriP the hose burst sensor has been triggered Check for a hose burst 2 l_t_trP suspected motor overtemperature Allow motor to cool and restart inverter 8 1 Hose Burst Detection and Vent Kit Hose burst sensor supplied as standard with the iDura have been pre wired to the inverter No further wiring has to be done by the user to use the hose burst detection Verderflex hose burst dete...

Страница 12: ...ed 1 Yes 21 Speed 2 Yes 22 Speed 3 Yes 23 Speed 4 Yes 24 2nd ramp time fast stop Yes 25 Analogue output function select Yes 26 Skip frequency hysteresis band Yes 27 Skip frequency centre point Yes 28 V F characteristic adjustment voltage No 29 V F characteristic adjustment frequency No 30 Start mode automatic restart fire mode operation Yes 31 Keypad start mode select No 32 DC injection mode and d...

Страница 13: ...I controller operating mode Yes 44 PI reference source select Yes 49 PI control wake up error level No 50 User output relay hysteresis Yes 51 Motor control mode Yes 52 Motor parameter autotune Yes 53 Vector mode gain No 54 Max current limit in vector control No 55 Motor stator resistance No 56 Motor stator d axis inductance No 57 Motor stator q axis inductance No 58 DC injection speed No 59 DC inj...

Страница 14: ...Fastening Lifting Gear to Pump 3 1 2 Figure 2 Wiring Diagram Single and 3 Phases Supply 4 3 Figure 3 iDura Inverter Overview 5 9 2 List of Tables Table 1 Target Groups 1 1 Table 2 Warnings Used in the Manual 1 2 Table 3 Symbols Used in the Manual 1 2 Table 4 iDura Inverter Parameters 8 2 Table 5 Declaration of Conformity 10 ...

Страница 15: ...IV 05 iDura MK IV 07 iDura MK III 10 iDura MK III 15 iDura MK III 25 iDura MK III 35 EC directives Machinery Directive 2006 42 EC Low voltage directive 2014 35 EU EMC directive 2014 30 EU RoHS Directive 2011 65 EU and Delegated Directive EU 2015 863 Applicable harmonized norms EN ISO 12100 2010 Manufacturer VERDER Ltd Unit 3 California Drive Castleford WF10 5QH UK Date 01 11 2020 Company Stamp Sig...

Страница 16: ...f the inspection window 11 7 Rotor Options Verderflex iDura 5 35 range has only standard pressure rotor as follows Table 1 Pump Specifications Size Value Max delivery pressure iDura 5 7 5 bar iDura 10 25 6 bar iDura 35 6 bar Temperature of pumped liquid 100 C subject to hose material Max continuous operation pump speeds refer pump datasheet Dimensions refer pump datasheet Table 2 Tightening Torque...

Страница 17: ... V No permission is granted to use any Verder trademarks or trade names included in this document without the prior written agreement of Verder International B V Modbus is a registered trademark of Schneider electric USA INC Tri clamp is a registered trademark of Alfa Laval Corporate AB Hypalon is a registered trademark of RSCC Wire Cable LLC ...

Отзывы: