Verderflex iDura 10 Скачать руководство пользователя страница 5

iDura 05-35

Version 1.0v-11/2020

© Verder International B.V

5 | Page

2  Safety 

 

The manufacturer does not accept any liability for damage 

resulting from disregard of this documentation as well as 

instructions in pump, motor, gearbox and inverter manu

-

als.

2.1   Intended Use

u

  Only  use  the  pump  to  handle  compatible  fluids  as 

recommended by the manufacturer (

g

 11 Technical 

Specifications).

u

  Adhere to the operating limits.

u

  Consult the manufacturer regarding any other use of the 

pump.

u

  Inverters should be wired to the power supply before use 

and this should be completed only by qualified personal 

and in accordance with the provisions of EMC Directive 

and EC Machinery Directive 2006/42/EC.

Prevention of obvious misuse (examples)

u

 

Note the operating limits of the pump with regard to tem- 

perature, pressure, flow rate, motor speed and frequency 

(

g

 11 Technical Specifications).

u

  Do not operate the pump with any inlet/outlet valves closed

u

  Install the inverter as recommended in this man-

ual, in conjunction with instructions in the pump, 

motor,  gearbox  and  inverter  instruction  manuals.

 

For example, the following are not allowed:

 –  Installing the pump without proper support.

 –  Installation in the immediate vicinity of extreme hot or 

cold sources.

2.2   General Safety Instructions

 

  Observe the following regulations before carrying 

 

out any work.

2.2.1  Product Safety

 

These operating instructions contain fundamental infor-

mation which must be complied with during installation, 

operation and maintenance. Therefore this operating 

manual must be read and understood both by the 

installing personnel and the responsible trained personnel 

/ operators prior to installation and commissioning, and it 

must always be kept easily accessible within the operating 

premises of the machine.

 

Not only must the general safety instructions laid down 

in this chapter on “Safety” be complied with, but also the 

safety instructions outlined under specific headings.

• 

Operate the pump only if it and all associated systems are 

in good functional condition. 

• 

Only use the pump and inverter as intended, fully aware of 

safety and risk factors involved and the instructions in this 

manual.

• 

Keep  this  manual  and  all  other  applicable  documents 

complete, legible and accessible to personnel at all times.

• 

Refrain from any procedure or action that would pose a 

risk to personnel or third parties.

• 

In the event of any safety-relevant faults, shut down the 

pump immediately and have the malfunction corrected by 

qualified personnel.

• 

The installation of the pump must comply with the require

-

ments of installation given in this manual and any local, 

national or regional health and safety regulations. 

• 

The pump and drive unit must not be mounted in direct 

sunlight or exposed to rain without suitable shade cover 

which is well ventilated.

2.2.2  Obligation of the Operating Company

Safety-conscious operation

•  Ensure that the following safety aspects are 

 

 

observed and monitored:

 

–  Adherence to intended use

 

–  Statutory or other safety and accident-prevention 

 

   regulations

 

– Safety regulations governing the handling of 

 

 

  hazardous substances if applicable

 

–  Applicable standards and guidelines in the country 

 

  where the pump is operated

• 

Make  personal  protective  equipment  available 

 

 

pertinent to operation of the pump.

Qualified personnel

• 

Ensure that all personnel tasked with work on the pump 

 

have read and understood this manual and all other  

  applicable documents, including the safety, 

 

 

maintenance and repair information, prior to use or  

 

installation of the pump.

• 

Organize  responsibilities,  areas  of  competence    and

 

  

the supervision of personnel.

• 

Have  all  work  carried  out  by  specialist  technicians

 

  

only.

•  Ensure that trainee personnel are under the 

 

 

supervision of specialist technicians at all times when 

 

working with the pump.

Safety equipment

 

Provide the following safety equipment and verify its

  

functionality:

– 

For  hot,  cold  and  moving  parts:  safety  guarding 

should be provided by the operating company.

– 

For potential build up of electrostatic charge: ensure 

appropriate grounding if and when required.

Содержание iDura 10

Страница 1: ...Peristaltic Industrial Hose Pump Supplementary Document Version 1 0v 11 2020 Print No 01 iDura 5 7 10 15 25 35 ...

Страница 2: ...ion 1 0v 11 2020 Print No 01 iDura 5 7 10 15 25 35 The information in this document is essential for the safe operation of Verderflex i Dura pumps This document must be read and understood thoroughly prior to installation of unit electrical con nection and commissioning ...

Страница 3: ...lectrical Connection 4 2 Electric Shock Hazard 4 3 Connecting to the Power Supply 5 Operation supplementary 6 Maintenance 6 1 Hose Change 6 1 1 Draining Lubricant 6 1 2 Hose Change Using Inverter 6 1 3 Hose Change Manually 6 1 4 Re installing the Hose Port Flanges Lubricant Refill and Fitting the Inspection Window 7 Service and Inspection of Electrical Components 8 Troubleshooting for the iDura In...

Страница 4: ...Operating Company u Keep this manual available at the operating site of the pump u Ensure that personnel read and follow the instructions in this manual and any other applicable documents especially all safety instructions and warnings u Observe any additional rules and regulations referring to the system Qualified personnel fitter u Read observe and follow this manual and the other applicable doc...

Страница 5: ...cific headings Operate the pump only if it and all associated systems are in good functional condition Only use the pump and inverter as intended fully aware of safety and risk factors involved and the instructions in this manual Keep this manual and all other applicable documents complete legible and accessible to personnel at all times Refrain from any procedure or action that would pose a risk ...

Страница 6: ...ted components Do not lean or step on them or use as climbing aid Do not use them to support boards ramps or beams Do not use them as a fixing point for winches or sup ports Do not de ice using gas burners or similar tools u Do not remove the safety guarding for hot cold or moving parts during operation u Reinstall the safety equipment on the pump as required by regulations after any repair mainte...

Страница 7: ... 85 non condensing Out of direct sunlight Frost free temperature range 5 to 45 C Vibration free Dust free 2 Depending on these conditions it may be advisable to place a moisture absorbing product such as Silica gel inside the pump s housing or to coat the pump s inner surfaces with moisture repelling oil such as WD40 whilst the pump is stored 3 Hoses should be stored as supplied in their wrapper a...

Страница 8: ...erience They must care fully read this safety information and the instructions in this Guide and follow all information regarding transport storage installation and use of the Inverter including the specified environmental limitations 3 Do not perform any flash test or voltage withstand test on the Inverter 4 In order to protect inverter and motor from high voltage or transient damage it is recomm...

Страница 9: ...osi tion and that power is available to the inverter 2 Switch on the inverter using the built in isolator switch and check no errors are displayed on screen 2 3 Directional switch governs which direction the pump will turn When set to the right position the pump should turn clockwise if not refer to g 4 3 Connecting to the Power Supply 4 Speed dial allows governance over pump rotor speed be tween ...

Страница 10: ...of both clamp rings where fitted 2 Set directional dial to whichever direction is preferable and the speed dial to minimum setting 3 The motor will slowly drive out the hose If at this point you are performing inspection on the rotor or pump cavity turn off inverter and lock out using an appropriate lock out tag out 4 Clean the pump housing 5 Inspect the flanges for damage and signs of wear 6 1 3 ...

Страница 11: ...onfiguration 1 E TriP the hose burst sensor has been triggered Check for a hose burst 2 l_t_trP suspected motor overtemperature Allow motor to cool and restart inverter 8 1 Hose Burst Detection and Vent Kit Hose burst sensor supplied as standard with the iDura have been pre wired to the inverter No further wiring has to be done by the user to use the hose burst detection Verderflex hose burst dete...

Страница 12: ...ed 1 Yes 21 Speed 2 Yes 22 Speed 3 Yes 23 Speed 4 Yes 24 2nd ramp time fast stop Yes 25 Analogue output function select Yes 26 Skip frequency hysteresis band Yes 27 Skip frequency centre point Yes 28 V F characteristic adjustment voltage No 29 V F characteristic adjustment frequency No 30 Start mode automatic restart fire mode operation Yes 31 Keypad start mode select No 32 DC injection mode and d...

Страница 13: ...I controller operating mode Yes 44 PI reference source select Yes 49 PI control wake up error level No 50 User output relay hysteresis Yes 51 Motor control mode Yes 52 Motor parameter autotune Yes 53 Vector mode gain No 54 Max current limit in vector control No 55 Motor stator resistance No 56 Motor stator d axis inductance No 57 Motor stator q axis inductance No 58 DC injection speed No 59 DC inj...

Страница 14: ...Fastening Lifting Gear to Pump 3 1 2 Figure 2 Wiring Diagram Single and 3 Phases Supply 4 3 Figure 3 iDura Inverter Overview 5 9 2 List of Tables Table 1 Target Groups 1 1 Table 2 Warnings Used in the Manual 1 2 Table 3 Symbols Used in the Manual 1 2 Table 4 iDura Inverter Parameters 8 2 Table 5 Declaration of Conformity 10 ...

Страница 15: ...IV 05 iDura MK IV 07 iDura MK III 10 iDura MK III 15 iDura MK III 25 iDura MK III 35 EC directives Machinery Directive 2006 42 EC Low voltage directive 2014 35 EU EMC directive 2014 30 EU RoHS Directive 2011 65 EU and Delegated Directive EU 2015 863 Applicable harmonized norms EN ISO 12100 2010 Manufacturer VERDER Ltd Unit 3 California Drive Castleford WF10 5QH UK Date 01 11 2020 Company Stamp Sig...

Страница 16: ...f the inspection window 11 7 Rotor Options Verderflex iDura 5 35 range has only standard pressure rotor as follows Table 1 Pump Specifications Size Value Max delivery pressure iDura 5 7 5 bar iDura 10 25 6 bar iDura 35 6 bar Temperature of pumped liquid 100 C subject to hose material Max continuous operation pump speeds refer pump datasheet Dimensions refer pump datasheet Table 2 Tightening Torque...

Страница 17: ... V No permission is granted to use any Verder trademarks or trade names included in this document without the prior written agreement of Verder International B V Modbus is a registered trademark of Schneider electric USA INC Tri clamp is a registered trademark of Alfa Laval Corporate AB Hypalon is a registered trademark of RSCC Wire Cable LLC ...

Отзывы: