Veracity Coldstore CSTORE15-3U Скачать руководство пользователя страница 12

VERACITY 

COLDSTORE

  |  

CS

TORE

15-3U

 QUICK START GUIDE  | 

REV 3.0.

3

  |  

October 2018

  |  12 

4

 

Click 

Configure network settings

To show labels for the COLDSTORE configuration windows including 

Configure network 

settings

 click the 

 button. 

5

 

Put a check in the checkbox next to the COLDSTORE entry. 

The Interface 1 IPV4 protocol and IPV6 protocol and Interface 2 IPV4 protocol and IPV6 protocol 
tabs will update with the current network settings for the selected COLDSTORE. 

The Interface 1 tab shows the network settings for ETH1 network connection. Interface 2 tab the 
ETH2 network connection.  

6

 

Click the 

Interface 1

 tab. 

The IPV4 and IPV6 protocol tabs will be updated with the network settings for ETH1 network 
connection. One of the protocol tabs will show the current values of that protocol. 

7

 

Click the 

IPV4 protocol

 tab. 

The IPV4 Protocol tab for ETH1 connection of the selected COLDSTORE is shown. 

8

 

Enter the network settings in IPV4 format as required for your installation. 

Update the COLDSTORE 

IP address

, set the 

netmask 

and the 

default gateway

 using the 

dotted addressing form typical of IPV4.  

Optionally, set the 

DNS server

 address entries if fully qualified domain names might be used 

elsewhere, for example when entering the NTP server details. The NTP servers are set-up in a 
different COLDSTORE configuration window and can be done later. 

 

After following the remaining steps, your COLDSTORE will switch to the network settings requested. You

may need to alter your computers settings to re-establish a connection. 

9

 

Click 

Save

A confirmation message box is shown. 

10

 

Click 

OK

 to confirm the changes made, or 

Cancel

 to abandon the changes made. 

If OK was clicked, a confirmation banner will be displayed indicating that the changes have been 

Содержание Coldstore CSTORE15-3U

Страница 1: ...Quick Start GUIDE COLDSTORE CSTORE15 3U Version 3 0 3...

Страница 2: ...Overview F Chassis Mounting G System Connections H Disk Loading I Power Up Sequence J Front Panel Menu K COLDSTORE Set up and Maintenance Software SITESCAPE Installing SITESCAPE Getting Connected L Sy...

Страница 3: ...t No 2009 502184 The storage array should NOT be moved once powered up as this is very likely to cause disk damage this applies to all types of disk storage arrays Information in this guide is subject...

Страница 4: ...running Windows 7 or later Windows operating system Ethernet Network including network cables and a switch Preferred Video Management System see website for list of supported systems E System Overview...

Страница 5: ...unit on If network connection redundancy is required a second network cable can be connected between your network switch and the network port labelled ETH2 but before connecting ensure that the COLDS...

Страница 6: ...acity s technical support team Fitting 2 5 disk drives to the rear drive bays will not provide performance benefits and could the correct operation of the COLDSTORE I Power Up Sequence Once the disks...

Страница 7: ...the configuration of your firewall and ensure that the SITESCAPE has full unblocked network access For more information about installing and using SITESCAPE see COLDSTORE User s Guide Installing SITE...

Страница 8: ...have two Ethernet connections labelled ETH1 and ETH2 By default connection ETH1 has IP address 10 0 0 140 subnet mask 255 255 255 0 and gateway 10 0 0 1 This section assumes that the network settings...

Страница 9: ...ORE tab If a warning dialog or other notification is shown by a network firewall protection application choose to allow the SITESCAPE application full access to the network 8 Click the COLDSTORES tab...

Страница 10: ...RE is eventually listed but with status offline and with error Device not found and a manually entered IP address for the COLDSTORE was used then it is possible that SITESCAPE is being prevented from...

Страница 11: ...correct and are writable See COLDSTORE User s Guide gives full details of all operations possible with SITESCAPE Correct time sync may be essential for correct operation depending upon application It...

Страница 12: ...at protocol 7 Click the IPV4 protocol tab The IPV4 Protocol tab for ETH1 connection of the selected COLDSTORE is shown 8 Enter the network settings in IPV4 format as required for your installation Upd...

Страница 13: ...the installation s network switch The SITESCAPE application can then be used to search for and add all the COLDSTORE devices on the installation s network to My Site SITESCAPE can then be used to ful...

Страница 14: ...in the array it may already have been faulty or may have been handled incorrectly during assembly It is essential that all disks are handled carefully are not dropped or even knocked against hard obje...

Отзывы: