TwinFresh Comfo RA(1)-50(-2)

DESIGN AND OPERATING LOGIC 

The ventilator consists of a telescopic air duct with adjustable length (inner part and outer part), a ventilation unit and an outer ventilation hood. 
The inner telescopic part contains two air filters and a ceramic regenerator. 
The air filters are designed to purify supply air and prevent foreign object ingress into the regenerator and the fan. 
The ceramic regenerator utilises extract air heat energy to warm up supply air flow. 
The regenerator is equipped with a pull cord inside to facilitate its withdrawal from the ventilator. 
The regenerator has a special heat insulation.
The ventilation unit must be installed on inner side of the wall. 
The outer ventilation hood is used for guided air discharge and prevention of direct ingress of water and other big objects to the ventilator.

VENTILATOR DESIGN 

Mounting plate 

A mounting box for 

installation the ventila-

tion unit on the wall and 

connecting the ventila-

tor to power supply. 

Outer duct 

Outer part of the 

telescopic air duct.

Outer ventilation 

hood 

Prevents direct 

ingress of water and 

foreign objects into 

the ventilator.

Filter 

Cleans the air flowing through the venti-

lator of dust and foreign objects and 

prevents contamination of the regenera-

tor. 

Ceramic regenerator

Utilises extract air heat 

energy to warm up 

supply air flow.

Ventilation unit 

Generates air flow by means of the 

fan rotation. The ventilation unit is 

covered with a ventilation grille on 

inner wall side to prevent ingress of 

foreign objects into the fan. The 

ventilation unit is equipped with 

automatic shutters to back draft 

prevention. The air shutters open 

during the ventilator activation and 

close during its shutdown. 

 

Inner air duct

Inner part of the 

telescopic air duct.

Air flow rectifier 

Prevents air turbulences 

in the ventilator.

Openings for humidity sensor

Provide contact of the humidity sensor with the 

indoor air for monitoring indoor humidity level.

Ventilator power indicator 

Shows operating status of the ventilator.

Filter replacement indicator.

Indicates the need to replace the filter. 

Infra-red receiver and light sensor

Responds to signals from the remote control and 

detects illumination level to activate/deactivate the 

night mode. 

Содержание RA1-50-2

Страница 1: ...USER S MANUAL Single room reversible energy regeneration ventilator TwinFresh Comfo RA 50 TwinFresh Comfo RA1 50 TwinFresh Comfo RA 50 2 TwinFresh Comfo RA1 50 2...

Страница 2: ...manual must be turned over to the receiving operator Symbol legend WARNING DO NOT The user s manual consisting of the technical details operating instructions and technical specification applies to th...

Страница 3: ...the unit to power mains Do not touch the unit controls with wet hands Do not carry out the installation and maintenance operations with wet hands Do not allow children to operate the unit Do not stor...

Страница 4: ...ed in the user s manual Do not operate the unit in aggressive or explosive environments Do not wash the unit with water Protect the electric parts of the unit against ingress of water Disconnect the u...

Страница 5: ...rous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs PURPOSE THE UNIT MAY NOT BE OPERATED BY CH...

Страница 6: ...I Supply Voltage 50 60 Hz V 1 100 230 Power consumption W 4 5 5 0 7 0 Total current consumption A 0 02 0 03 0 04 Air capacity m3 h CFM 21 12 32 19 50 30 RPM min 1 610 800 1450 Noise level 1 m dB A Son...

Страница 7: ...part of the telescopic air duct Outer ventilation hood Prevents direct ingress of water and foreign objects into the ventilator Filter Cleans the air owing through the venti lator of dust and foreign...

Страница 8: ...are opened In Regeneration mode the ventilator operates in two cycles 70 seconds each Cycle I Warm stale air is extracted from the room As it flows through the regenerator it heats and moisturizes th...

Страница 9: ...A A A A 2 Insert the air duct in the wall using the supplied polystyrene wedges and fix it with mounting foam The telescopic air duct end protruding part must enable installation of the outer ventilat...

Страница 10: ...g plate from the ventilation unit by disconnecting the two connectors Re assemble the mounting plate in the reverse order Install the cables with care 4 Install the mounting plate unit using the suppl...

Страница 11: ...Air direction in the Ventilation mode is determined by position of the jumper on the control board The control board of the ventilator is located inside of the ventilation unit DISCONNECT THE UNIT FR...

Страница 12: ...use a power cable with the minimum wire cross section 0 5 mm2 and a control cable with the minimum wire cross section 0 25 mm2 The cables are not included in the delivery set The cable must be rated...

Страница 13: ...2 x 0 25 mm2 Connect the ventilators no 12 20 to the ventilator no 11 in the same way as the ventilators no 1 10 All the connected ventilators are controlled with the ventilator no 1 CONNECTION OF MOR...

Страница 14: ...jumper position The fan is off The ventilator does not operate The shutters are closed Regeneration mode In this mode the ventilator switches between supply and extract mode each 70 seconds with heat...

Страница 15: ...setting or supplied at a selected speed All the ventilators connected in series ventilators operate depending on position of CN7 jumper Regeneration mode The ventilator operates 70 seconds in Supply...

Страница 16: ...ce 3 4 times per year 1 Remove the air flow rectifier 2 Remove the filter in front of the regenerator 3 Pulltheregeneratorcordtoremovetheregenerator from the air duct 4 Be careful while pulling the re...

Страница 17: ...tall the holder with a new battery in site CR2025 3V CR2025 3V TROUBLESHOOTING Fault Possible reasons Remedy The fan does not start running during start up of the ventilator No power supply Make sure...

Страница 18: ...IAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitations of incidental or consequential damages so the above limitat...

Страница 19: ...umber E mail Purchase Date Seller s Stamp Seller s Stamp Installation Company Stamp This is to certify acceptance of the complete ventilator delivery with the user s manual The warranty terms are ackn...

Страница 20: ...V US123 TFC RB RA EN 03...

Отзывы: