www.vents-us.com
13
TwinFresh Comfo RA(1)-50(-2)
In case of connection above 10 ventilators the ventilator 11 is energized not though the previous ventilator but from power mains (L and N terminals).
The control signals G and D from the 10th ventilator are transmitted through the cable 2xAWG23 (2 x 0.25 mm
2
.)
Connect the ventilators no. 12…20 to the ventilator no. 11 in the same way as the ventilators no. 1…10.
All the connected ventilators are controlled with the ventilator no. 1.
CONNECTION OF MORE THAN 10 VENTILATORS IN SERIES
ALL THE CONNECTED IN SERIES VENTILATORS MUST BE GROUNDED!
1~100-230
V/50-60 Hz
1~100-230
V/50-60 Hz
Power cable
Control cable
to the nex
t v
entilat
or
Control cable
INPUT
OUTPUT
L
G
D
N
L
G
D
N
INPUT
OUTPUT
L
G
D
N
L
G
D
N
INPUT
OUTPUT
L
G
D
N
L
G
D
N
№1
№10
№11