Production meets standard operating requirements in the USA and Canada.
Vents US warrants to the original purchaser of the unit that it will be free from defects in materials or workmanship for a period of 24 months 
from the date of original purchase. The Vents US warrants to the original purchaser of the unit that the integrated control unit will be free from 
defects in materials and workmanship for a period of 24 months from the date of original purchase.

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, 

IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During the stated warranty period, Vents US will, at its option, repair or replace, without charge, any product or part which is found to be 
defective under normal use and service. This warranty does not cover (a) normal maintenance and normal service or (b) any products or 
parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Vents US), faulty installation 
or installation contrary to recommended installation instructions. Labor to remove and replace products is not covered. The duration of any 
implied warranty is limited to the time period specified for the express warranty. Some states do not allow limitations on how long an implied 
warranty lasts, so the above limitation may not apply to you.

VENTS US OBLIGATION TO REPAIR OR REPLACE, AT VENTS US OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE 

REMEDY UNDER THIS WARRANTY. VENTS US SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES 

ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.

Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not 
apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty 
supersedes all prior warranties. If proof of sales date is absent, warranty period is calculated from the production date. The unit can be 
exchanged at the following address:

11013 Kenwood Rd, Cincinnati, Ohio 45242
Tel: 1-888-640-0925, 513-583-5786
Fax: 513-268-4597
E-mail: [email protected]

[email protected]
[email protected]

Please follow guidelines in this manual for product problem-free operation.

MANUFACTURER’S WARRANTY

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND 

TROUBLE-FREE OPERATION OF THE UNIT.

USERS’ WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON 

PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S 

MANUAL WITH THE PURCHASE DATE STAMP.

STORAGE AND TRANSPORTATION REGULATIONS  

Store the unit in the manufacturer’s original packing box in a dry ventilated premise at ambient temperatures from +5 ˚C ( +41 ˚F) up to +40 ˚C (104 ˚F).
Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation and sealing deformation.
Use suitable hoist machinery  for handling and storage operations to prevent possible damage to the unit.
Follow the handling requirements applicable for the particular type of cargo. 
The unit can be carried in the original packing by any mode of transport provided proper protection against precipitation and mechanical damage. 
Avoid sharp blows, scratches or rough handling during loading and unloading.

Содержание RA1-50-2

Страница 1: ...USER S MANUAL Single room reversible energy regeneration ventilator TwinFresh Comfo RA 50 TwinFresh Comfo RA1 50 TwinFresh Comfo RA 50 2 TwinFresh Comfo RA1 50 2...

Страница 2: ...manual must be turned over to the receiving operator Symbol legend WARNING DO NOT The user s manual consisting of the technical details operating instructions and technical specification applies to th...

Страница 3: ...the unit to power mains Do not touch the unit controls with wet hands Do not carry out the installation and maintenance operations with wet hands Do not allow children to operate the unit Do not stor...

Страница 4: ...ed in the user s manual Do not operate the unit in aggressive or explosive environments Do not wash the unit with water Protect the electric parts of the unit against ingress of water Disconnect the u...

Страница 5: ...rous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs PURPOSE THE UNIT MAY NOT BE OPERATED BY CH...

Страница 6: ...I Supply Voltage 50 60 Hz V 1 100 230 Power consumption W 4 5 5 0 7 0 Total current consumption A 0 02 0 03 0 04 Air capacity m3 h CFM 21 12 32 19 50 30 RPM min 1 610 800 1450 Noise level 1 m dB A Son...

Страница 7: ...part of the telescopic air duct Outer ventilation hood Prevents direct ingress of water and foreign objects into the ventilator Filter Cleans the air owing through the venti lator of dust and foreign...

Страница 8: ...are opened In Regeneration mode the ventilator operates in two cycles 70 seconds each Cycle I Warm stale air is extracted from the room As it flows through the regenerator it heats and moisturizes th...

Страница 9: ...A A A A 2 Insert the air duct in the wall using the supplied polystyrene wedges and fix it with mounting foam The telescopic air duct end protruding part must enable installation of the outer ventilat...

Страница 10: ...g plate from the ventilation unit by disconnecting the two connectors Re assemble the mounting plate in the reverse order Install the cables with care 4 Install the mounting plate unit using the suppl...

Страница 11: ...Air direction in the Ventilation mode is determined by position of the jumper on the control board The control board of the ventilator is located inside of the ventilation unit DISCONNECT THE UNIT FR...

Страница 12: ...use a power cable with the minimum wire cross section 0 5 mm2 and a control cable with the minimum wire cross section 0 25 mm2 The cables are not included in the delivery set The cable must be rated...

Страница 13: ...2 x 0 25 mm2 Connect the ventilators no 12 20 to the ventilator no 11 in the same way as the ventilators no 1 10 All the connected ventilators are controlled with the ventilator no 1 CONNECTION OF MOR...

Страница 14: ...jumper position The fan is off The ventilator does not operate The shutters are closed Regeneration mode In this mode the ventilator switches between supply and extract mode each 70 seconds with heat...

Страница 15: ...setting or supplied at a selected speed All the ventilators connected in series ventilators operate depending on position of CN7 jumper Regeneration mode The ventilator operates 70 seconds in Supply...

Страница 16: ...ce 3 4 times per year 1 Remove the air flow rectifier 2 Remove the filter in front of the regenerator 3 Pulltheregeneratorcordtoremovetheregenerator from the air duct 4 Be careful while pulling the re...

Страница 17: ...tall the holder with a new battery in site CR2025 3V CR2025 3V TROUBLESHOOTING Fault Possible reasons Remedy The fan does not start running during start up of the ventilator No power supply Make sure...

Страница 18: ...IAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitations of incidental or consequential damages so the above limitat...

Страница 19: ...umber E mail Purchase Date Seller s Stamp Seller s Stamp Installation Company Stamp This is to certify acceptance of the complete ventilator delivery with the user s manual The warranty terms are ackn...

Страница 20: ...V US123 TFC RB RA EN 03...

Отзывы: