FP15 & FP15A Waterloo - Installation and Operation Manual
55
7.6.2
Exterior Offset Installation
7.6.3
Installation Instructions
WARNING
•
THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
•
THE FLOOR AND WALLS BELOW THE ATTIC MUST BE INSULATED USING THE SAME INSULATION.
A
To insure a good draft, it is
recommended to have a length of 18
inches from the top of the unit to the
first offset. However, starting using a
30° or 45° elbow is also approved.
B
Mandatory measure of 15 ft. from the
bottom of the fireplace to the top of
the outside chimney.