60
FP15 & FP15A Waterloo - Installation and Operation Manual
7.9
Installation Instructions for Masonry Application
WARNING
BEFORE STARTING THE INSTALLATION, THE MASONRY CHIMNEY MUST BE INSPECTED BY A QUALIFIED
CHIMNEY SWEEPER.
The following requirements must be respected:
1.
The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing
bricks that could inhibit correct installation of the liner.
2.
The clearance to combustible must be a minimum of 1" between the outside of the masonry and any
wood framing or loose insulation.
3.
The chimney must be built in accordance with the current building code.
4.
No other appliance can be connected to the same chimney.
NOTE
•
THE CHIMNEY MUST BE RELINED WITH A STAINLESS STEEL LINER OF THE SAME DIAMETER AS THE
OUTLET OF THE FIREPLACE.
•
FOR CONNECTION AT 30° OR 45° ANGLE (30° OR 45° IN CANADA AND 30° ONLY IN THE USA), A
SPECIAL CONNECTOR MUST BE USED TO CONNECT THE LINER TO THE INSULATED CHIMNEY. VERIFY
AVAILABILITY AND INSTALLATION INSTRUCTIONS FOR THIS CONNECTOR WITH THE CHIMNEY
MANUFACTURER.
7.9.1
Installation instructions
1.
Position the fireplace in its location. Temporarily install the elbow
or chimney section
(A)
on the top of the fireplace and, using a level,
mark with an oval the location where the flue liner will enter the
masonry chimney.
2.
In the middle of the oval, drill a hole in the masonry chimney at 45
°
or 30
°
.
3.
Increase the size of the hole until a 45
°
or 30
°
insulated liner
adapter
(B)
can be easily slipped through.
4.
Slide the liner
(C)
down from the top of the masonry chimney until
you reach the hole level.
5.
Slip through the hole a 45
°
or 30
°
insulated liner adapter and
connect it to the liner.
6.
Seal the opening around the liner with high temperature refractory
cement.
7.
Then, follow the chimney manufacturer’s instructions to connect
the extended liner section to the special chimney connector.
Note:
Make sure the liner exceeds at least 12” (30 cm) the top of
masonry chimney.
Содержание Waterloo FP15
Страница 10: ...10 FP15 FP15A Waterloo Installation and Operation Manual 2 3 Measurements FP15 ...
Страница 11: ...FP15 FP15A Waterloo Installation and Operation Manual 11 ...
Страница 12: ...12 FP15 FP15A Waterloo Installation and Operation Manual 2 4 Measurements FP15A ...
Страница 13: ...FP15 FP15A Waterloo Installation and Operation Manual 13 ...
Страница 77: ...FP15 FP15A Waterloo Installation and Operation Manual 77 ...
Страница 78: ...78 FP15 FP15A Waterloo Installation and Operation Manual APPENDIX 9 EXPLODED DIAGRAM AND PARTS LIST FP15 ...
Страница 82: ...82 FP15 FP15A Waterloo Installation and Operation Manual APPENDIX 10 Exploded Diagram and Parts List FP15A ...
Страница 87: ...NOTES ...
Страница 88: ...88 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 89: ......