FP15 & FP15A Waterloo - Installation and Operation Manual
57
7.6.4
Offset Chimney Installation
TABLE 2 - MINIMUM SYSTEM HEIGHT WHEN USING ELBOWS
Fireplace model
WATERLOO
Chimney model
All models (see
TABLE 3)
Vertical installation
15 ft. (4.6 m)
Two (2) elbows
15 ft. (4.6 m)
Four (4) elbows
17 ft. (5.2 m)
After reaching the location requiring the elbow, proceed as follows:
1.
To insure a good draft, it is recommended, to have a length of 18 inches (457 mm) from the top of the
unit to the first offset. Install the first elbow; turn it in the required direction. Secure it to the chimney
according to the chimney manufacturer’s instructions. In many cases, it is recommended to secure
connections with three (3) ½" (12 mm) metal screws.
2.
Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together
according to the chimney manufacturer’s instructions. In many cases, it is recommended to use three
(3) ½" (12 mm) metal screws. If the offset length is made of two (2) chimney lengths or more, many
chimney manufacturers may require that you use an offset or roof support halfway up the offset. If
penetrating a wall, install a wall radiation shield supplied by the chimney manufacturer.
3.
Use another elbow to turn the
chimney
vertically. Secure the elbow.
4.
Use a plumb bob to line up the centre of the hole. Cut a hole for the chimney in the ceiling/floor. Frame
this hole as described previously.
5.
From below, install a firestop supplied by the chimney manufacturer.
6.
A support must be used on the first 15' section (4.6 m).
7.
Continue with the regular installation.
WARNING
•
IN EVERY CASE, THE CHIMNEY MUST START WITH A 8'' DIAMETER
ANCHOR PLATE SECURED TO THE FIREPLACE. (SOLD SEPARATELY).
•
IF THE MALE NOZZLE (A) OF THE ANCHOR PLATE EXCEEDS 2" (51
MM) IN LENGTH (SEE IMAGE BELOW), IT SHALL BE CUT ABOVE
THE LIFTING HOOKS WELDED TO THE INSIDE OF THE FLUE OUTLET
SO THAT THE ANCHOR PLATE RESTS PERFECTLY ON TOP OF THE
FIREPLACE.
Содержание Waterloo FP15
Страница 10: ...10 FP15 FP15A Waterloo Installation and Operation Manual 2 3 Measurements FP15 ...
Страница 11: ...FP15 FP15A Waterloo Installation and Operation Manual 11 ...
Страница 12: ...12 FP15 FP15A Waterloo Installation and Operation Manual 2 4 Measurements FP15A ...
Страница 13: ...FP15 FP15A Waterloo Installation and Operation Manual 13 ...
Страница 77: ...FP15 FP15A Waterloo Installation and Operation Manual 77 ...
Страница 78: ...78 FP15 FP15A Waterloo Installation and Operation Manual APPENDIX 9 EXPLODED DIAGRAM AND PARTS LIST FP15 ...
Страница 82: ...82 FP15 FP15A Waterloo Installation and Operation Manual APPENDIX 10 Exploded Diagram and Parts List FP15A ...
Страница 87: ...NOTES ...
Страница 88: ...88 FP15 FP15A Waterloo Installation and Operation Manual ...
Страница 89: ......